background image

Confirm that the vent tube has been mounted properly. 

 

• When using functions on cooling and dehumidifying, keep an interval of at least 3 minutes 

between each ON/OFF. 

• Be sure wall socket provides standard 110-115V AC, 60Hz use. 

• Do not share one socket with other appliances. 

• 

Press the “MODE” button until the “Cool” or “Heat” (for models with Heat) icon appears. 

•  Press the “DOWN” or “UP” button to select a desired room temperature between 61-88°F (16-31°C). 

• 

Press the “SPEED” button to select fan speed. 

• 

Press the “MODE” button until the “Dehumidify” icon appears.

• 

The unit will automatically set the selected temperature to current room temperature minus 

 2°C/4°F

• 

The unit will automatically set the fan LOW speed. 

 

IMPORTANT: 

Please read manual section “WATER DREAINAGE” regarding options for draining 

collected water from the unit.

• 

Press the “MODE” button until the “Fan” icon appears.

• 

Press the “SPEED” button to select fan speed.

Timer ON setting: 

• 

When the air-conditioner is OFF, press the “TIMER” button and select a desired ON time using the 

“UP” and “DOWN” buttons. 

• 

Confirm the selected time by pressing the “TIMER” button once. (If you do not confirm, the TIMER 

“ON” will not go into effect.)

• 

Selected ON time is displayed on the operation panel. 

• 

ON time can be set to 0-24 hours in 1-hour increments. 

Timer OFF setting:

• 

When the air-conditioner ON, press “TIMER” button and select a desired OFF time using the “UP” and 

“DOWN” buttons. 

• 

Confirm the selected time by pressing the “TIMER” button once. (If you do not confirm, the TIMER 

“OFF” will not go into effect.)

• 

Selected OFF Time is displayed on the operation panel. 

• 

OFF time can be set to 0-24 hours in 1-hour increments. 

• 

After machine turns on, press this key ON REMOTE CONTROL and the louver will swing continuously 

up and down. By pressing this button again, the movement will stop, and the louver remain in that 

position. 

• 

While in cooling mode, press the SLEEP key ON REMOTE CONTROL to set the temperature. It 

increases 

 1°C/2°F

 after an hour and at most increases 

 2°C/4°F

 after 2 hours.

CAUTIONS

Cooling OR 

Heating

Dehumidifying

Fan

Timer

Swing

(Flow Direction)

Sleep

9

operation

8

Buttons

and

Indicators

INDICATORS

BUTTONS

TIMER 

Timer ON/OFF setting.

MODE

Select cooling, dehumidifying, fan or heat mode

DOWN

Set the temperature (or time), the temperature 

(or time) will drop by 1°C/1°F (or 1 hour) with 

each press.

UP

 

Set the indoor temperature (or time), the 

temperature (or time) will rise by 1°C/1°F 

(or 1 hour) with each press.

SPEED 

 

Press to select either LOW, MEDIUM, 

or HIGH fan speed.

POWER

 

Press to turn ON/OFF the unit.

Sleep 

(Run from remote)

Timer setting

Heat mode 

(Heat models only)

Fan mode

Dehumidify mode

Cool mode

Swing 

(Run from remote)

High fan

Mid fan

Low fan

Water full

Main unit control panel indicators also 

apply to remote control display area.

Button functions on remote control operate 

in same manner as main unit control panel.

control panel

& remote functions

HEAT MODELS ONLY

(Heat

models

only)

Signal

strength

Note:

• Do not drop the remote controller.

• Do not place the remote controller in a  

  location  exposed to direct sunlight.

Содержание AC08MWS

Страница 1: ...ope you will enjoy your portable air conditioner trouble free in the years ahead If you do have any questions however regarding this manual installation or operation please know that we are always here to assist you with any concern 1 800 838 1198 airocomfort com contact support airocomfort com 14 reaching airo comfort ...

Страница 2: ...egistration is not required to activate any warranty BEFORE FIRST USE To prevent any internal damage it is very important to keep your airo comfort air conditioner standing upright and outside the box for 24 HOURS before plugging it in SAVE THIS MANUAL FOR FUTURE REFENCE TABLE OF CONTENTS Important Safety Instructions 2 Housing Parts Description 3 Assembly Preparation 4 Window Installation 1 5 Win...

Страница 3: ...e to water can cause electrical components to short circuit DO NOT install the air conditioner in a place that may be exposed to combustible gas as this could cause fire The appliance must be kept free from obstruction to ensure proper function and to mitigate safety hazards DO NOT modify the length of the power cord or use an extension cord to power the unit DO NOT share a single outlet with othe...

Страница 4: ...ow With the ring flush to the tube end twist the ring so the leading point of the tube coil slides into the inner ring grooves Twist enough rotations for a solid connection and repeat for other tube end Insert the Unit Adapter the Unit Adapter Tab should remain right side up of the Vent Tube assembly into the lower groove of the air outlet while the tab on the adapter ring is aligned with the air ...

Страница 5: ...hown 5 Insert the tube Window Slider Adapter into the hole of the Window Slider window installation 1 Method 1 SlidingWindow Installation OPTIONAL Foam seal C 1 2 3 4 6 1 Cut Foam Seal A and B strips to the proper lengths and remove the adhesive backing Attach them to the window sash and frame as shown 2 Insert the Window Slider assembly into the window opening 3 Cut the non adhesive Foam Seal C s...

Страница 6: ... by pressing the TIMER button once If you do not confirm the TIMER OFF will not go into effect Selected OFF Time is displayed on the operation panel OFF time can be set to 0 24 hours in 1 hour increments After machine turns on press this key ON REMOTE CONTROL and the louver will swing continuously up and down By pressing this button again the movement will stop and the louver remain in that positi...

Страница 7: ... dicates that the collected water needs to be drained using either of the following procedures With manual draining both rear drain spout caps are tightly sealed during normal operation The WATER FULL indicator will illuminate when the internal water container is filled to the level when it needs to be emptied After turning the unit off place a shallow pan under the air conditioner as shown in the...

Страница 8: ...ment which are covered below IMPORTANT You must register your air conditioner purchase with airo comfort within 60 days on our web site airocomfort com warranty for the limited warranties described in sections 2 and 3 to be in full compliance Unregistered purchases may incur fees if service repair is needed Defects in materials and workmanship of Covered Equipment that appear under normal use and ...

Отзывы: