Make sure that you install your unit on an even surface for minimal noise and vibration. 

The unit must be installed near a grounded plug and the Bottom Tray Drain Outlet (on the back of the 

unit) must be accessible.       

 

 Medium Philips screwdriver 

• Tape measure or ruler 

• Knife or scissors 

• Saw (optional, to shorten Window Slider Adapter for narrow windows) 

There are two ring adapters which when are attached to the flexible/extendable tube will allow connec-

tion between the air conditioner and the window slide adapter. Each of the adapter rings attach to the 

tube end in the same manner.

Begin with taking a small portion of the tube end and extend it out by grasping end with your fingers and 

pulling out and away. 

Before

You

Begin

Tools

Needed

STEP ONE:

Preparing 

the Vent Tube 

Assembly 

Minimum unit to wall surface distance

assembly

preparation

Alignment

Tab

1

2

STEP TWO:

Installing the 

Vent Hose 

Assembly to the 

Unit 

STEP THREE:

Preparing the 

Adjustable 

Window Slider

5

Orient the ring adapters to the tube end as shown in the diagram below. With the ring flush to the tube 

end, twist the ring so the leading point of the tube coil slides into the inner ring grooves. Twist enough 

rotations for a solid connection and repeat for other tube end.

Insert the Unit Adapter (the Unit Adapter Tab should remain right-side up) of the Vent Tube assembly 

into the lower groove of the air outlet while the tab on the adapter ring is aligned with the air outlet. 

Slide down the Unit Adapter. The tube will slide in and lock in place.

1

3

2

A

B

Underside 

View

Based on the size of your window, adjust the size of the Window Slider. 

If the width of the window is short use slider section “A” and cut to size, sections “A” and “B” for 

mid-length or all three sections “A” and “B” and “C” for extra length if  needed for vertical installations.

Assembly steps:

• 

Start with slider section (A) and insert a T-screw 

mount (1) through the underside hole (2) and screw on 

locking knob (3) VERY LOOSELY.

• 

Slide the assembled section (A) around the end of 

section (B) with the T-screw sliding into the center 

channel groove.

• 

Repeat for section (C) if needed and adjust completed 

slider length to window measurement.

• 

Tighten locking knobs to secure panel connection.

C

B

A

Topside View

UNIT

ADAPTER

WINDOW SLIDER

ADAPTER

(CLOCKWISE ROTATION)

Содержание AC08MWS

Страница 1: ...ope you will enjoy your portable air conditioner trouble free in the years ahead If you do have any questions however regarding this manual installation or operation please know that we are always here to assist you with any concern 1 800 838 1198 airocomfort com contact support airocomfort com 14 reaching airo comfort ...

Страница 2: ...egistration is not required to activate any warranty BEFORE FIRST USE To prevent any internal damage it is very important to keep your airo comfort air conditioner standing upright and outside the box for 24 HOURS before plugging it in SAVE THIS MANUAL FOR FUTURE REFENCE TABLE OF CONTENTS Important Safety Instructions 2 Housing Parts Description 3 Assembly Preparation 4 Window Installation 1 5 Win...

Страница 3: ...e to water can cause electrical components to short circuit DO NOT install the air conditioner in a place that may be exposed to combustible gas as this could cause fire The appliance must be kept free from obstruction to ensure proper function and to mitigate safety hazards DO NOT modify the length of the power cord or use an extension cord to power the unit DO NOT share a single outlet with othe...

Страница 4: ...ow With the ring flush to the tube end twist the ring so the leading point of the tube coil slides into the inner ring grooves Twist enough rotations for a solid connection and repeat for other tube end Insert the Unit Adapter the Unit Adapter Tab should remain right side up of the Vent Tube assembly into the lower groove of the air outlet while the tab on the adapter ring is aligned with the air ...

Страница 5: ...hown 5 Insert the tube Window Slider Adapter into the hole of the Window Slider window installation 1 Method 1 SlidingWindow Installation OPTIONAL Foam seal C 1 2 3 4 6 1 Cut Foam Seal A and B strips to the proper lengths and remove the adhesive backing Attach them to the window sash and frame as shown 2 Insert the Window Slider assembly into the window opening 3 Cut the non adhesive Foam Seal C s...

Страница 6: ... by pressing the TIMER button once If you do not confirm the TIMER OFF will not go into effect Selected OFF Time is displayed on the operation panel OFF time can be set to 0 24 hours in 1 hour increments After machine turns on press this key ON REMOTE CONTROL and the louver will swing continuously up and down By pressing this button again the movement will stop and the louver remain in that positi...

Страница 7: ... dicates that the collected water needs to be drained using either of the following procedures With manual draining both rear drain spout caps are tightly sealed during normal operation The WATER FULL indicator will illuminate when the internal water container is filled to the level when it needs to be emptied After turning the unit off place a shallow pan under the air conditioner as shown in the...

Страница 8: ...ment which are covered below IMPORTANT You must register your air conditioner purchase with airo comfort within 60 days on our web site airocomfort com warranty for the limited warranties described in sections 2 and 3 to be in full compliance Unregistered purchases may incur fees if service repair is needed Defects in materials and workmanship of Covered Equipment that appear under normal use and ...

Отзывы: