![AirMan SDG1 00S-6A6 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/airman/sdg1-00s-6a6/sdg1-00s-6a6_instruction-manual_2878215030.webp)
4. Operation
4.2 Protection device
A
WARNING--------------------,
• For prevention of troubles during operation, this machine is provided with various protection devices. If
the engine should shut down or circuit-breaker should trip owing to functions of the protection devices,
make sure to check and remove such cause of trouble. Then start operation again.
4.2.1 Warning and Emergency Display lamp
Warning and Emergency Display
• When the warning lamp glows, stop the machine immediately and take appropriate measures
to recover the situation.
Item
Trouble
Lamp glows when engine oil pressure
drops during operation and then engine
Engine oil
stops. Operating pressure:
SDG25S lower than 15psi (0.lMPa)
pressure
SDG45S lower than 22psi (0.15MPa)
SDG65S lower than 15psi (0.lMPa)
SDGlO0S lower than 15psi (0.lMPa)
Lamp glows when coolant temperature
reaches and then engine stops:
Coolant
SDG25S more than230
°
F(llO"C)
temperature SDG45S more than230
°
F(llO"C)
SDG65S more than221
°
F(l.05"C)
SDGlO0S more than221
°
F(l.05"C)
This lamp goes on when operator fails to
Overcrank
start engine, during automatic operation
mode.
Lamp glows when alternator is not
Charging
charging.
The alternator functions properly when
the lamp goes out after engine starts.
When air filter gets clogged and
Air filter
differential pressure rises, lamp goes on.
Actuating differential pressure : more
than 0.9psi(6.2 kPa)
4-2
Measures
See 6.2
Troubleshooting
Monitor
Q
.@.,
ENG. OIL PRESS,
0
0
0
0
0
GR
WATER TEMP
@)
OVERCRANK
□
CHARGE
@>
GLOW
:5-.
AIR FILTER
BTW Equipment Supply • www.btwequipmentsupply.com • ORDER PARTS ONLINE