background image

1

The power supply

must adopt the 

special circuit that with air 

switch protection and assure 

Keep combustilble

spray away from the 

units more than 1m.

Don't block the air 
intake or outlet vents 

of both the outdoor and indoor  

units.

It can decrease the air conditioning 
capacity or cause a malfunction. 

Don’t leave windows
and doors open for

a long time while operating 

the air conditioner.

It can decrease the air 

conditioning capacity.

It can cause a fire or explosion

Don’t attempt to 
repair the air 

conditioner by yourself

.

The wrong repair will lead to

an electric shock or fire, so 

you should contact the service

center to repair.

Be sure to pull out

the power plug as

the air conditioner not in use 

for a long time. 

Otherwise, the accumulated

dusts that may cause over

heating or fire.

Never splice the 

power cord or use 

an extended cord.

It can cause overheating or 

fire.

When having a 
burning smell or 

smoke, please turn off the 

power supply and contact  

with the  service center.

If the abnormity still exists,

the unit may be damaged, 

and may cause electric 

shock or fire.

Please read the following carefully before operating

Notices for operation

components would be easily 

damaged, when the voltage 

is very low, the compressor 

vibrates terribly and that the 

refrigerant system will be 

damaged, the compressor 

and electric components 

cannot work, the voltage 

should be stable; there 

shouldn’t be big fluctuation. 

When the voltage 

is very high, the 

   

it has enough capacity.  

The unit will be turned

on or off according to your

requirement automatically, 

please do not turn on or turn

off the unit frequently, other-

wise disadvantage effect may

be caused to the unit.

Содержание 66129903294

Страница 1: ...AIRLUX AIR CONDITIONERS Thank you for choosing AIRLUX air conditioner for correct operation and keeps iand keepst carefully for consultation please read this owner s manual carefully before operating...

Страница 2: ......

Страница 3: ...ol Clean and care Troubleshooting Installation service Notices for installation Installation dimension diagram Install indoor unit Test operation and check after installation This symbol stands for th...

Страница 4: ......

Страница 5: ...the accumulated dusts that may cause over heating or fire Never splice the power cord or use an extended cord It can cause overheating or fire When having a burning smell or smoke please turn off the...

Страница 6: ...cause a bad influence to them Don t insert your hands or stick into the air intake or outlet vents Don t use the air conditioner for other purposes such as drying clothes preserving foods etc To adjus...

Страница 7: ...ed so room heating capacity If outdoor temperature got lower please operate with the other heating ventilating equipments Defrosting When outdoor temperature is low but high humidity after a long whil...

Страница 8: ...4 Names and functions of each part Indoor unit Air in Air out Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Remote control...

Страница 9: ...this button the clock can be set up signal blink and display Within 5 CLOCK button CLOCK seconds the value can be adjusted by pressing or button if continuously press this button for 2 seconds above i...

Страница 10: ...button Temperature of Celsius degree setting 16 30 for Fahrenheit degree setting 61 86 Presetting temperature can be decreased Press this button the temperature can be button set up continuously press...

Страница 11: ...Press this button to set swing angle which circularly changes as below OFF This remote controller is universal If it receives threes kinds of following status the swing angle will remain original If...

Страница 12: ...General operation Guide for operation Optional operation Operation of wireless remote control This function indicates that moisture on evaporator of indoor unit will be blowed after the unit About bl...

Страница 13: ...his new function If the unit is under defrost mode dual eight position on remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case pres...

Страница 14: ...ature to select the COOL HEAT FAN mode automatically to obtain the comfortable effect At stopping When the unit is running press the ON OFF button of the manual switch the unit will stop work The code...

Страница 15: ...el and take it out forcibly and then can take it off Washing Install front panel Place two supporters of the front panel into the slots along the direction of arrows to cover and clasp the front panel...

Страница 16: ...unit to prevent it from spreading a b Clean and care Take down the air filter Cleaning Reinsert the filters Reinsert the filters along with the arrow head then cover the surface panel and clasp it To...

Страница 17: ...not operate in approximately 3 minutes to protect itself The unit can not operte immediately when the air conditioner is restarted There s unusual smell blowing from the outlet after operation is sta...

Страница 18: ...ters dirty Are the windows and door closed Is indoor fan speed set at low speed Is there any other heat source in your room Cooling Heating efficiency is not good Remote control can t be used occasion...

Страница 19: ...nger is very low that will stop deliver air in order to prevent cool air Within 3min In HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor hea...

Страница 20: ...the obstruction make sure that the air can be blown through the whole room 2 Select a position where the condensing water can be easily drained out and the place is easily connected for outdoor unit 3...

Страница 21: ...e sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected there should be reliable and no short circuit in the diagram wrong connection may...

Страница 22: ...agram Installation dimension diagram Space to the ceiling Above Above Above Space to the wall Space to the wall 15cm 300 cm 2 15 cm Space to the floor Air outlet side Above cm cm 2 0 Installation dime...

Страница 23: ...od its end by water 3 When the long drainage hose passing through indoor should wrap the insulation materials Wrenched Bent Flooded Indoor Outdoor Wall pipe Seal pad Fig 1 Rear piping hole Rear piping...

Страница 24: ...routing the wiring only 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping or 1 2 3 Take out the piping from body case wrap the piping electric wire water pipe with tape a...

Страница 25: ...e earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient cooli...

Страница 26: ...lter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning I...

Страница 27: ......

Отзывы: