AirLive SNMP-FSH2602MG V2 Скачать руководство пользователя страница 1

SNMP-FSH2602MG v2 

24 + 2-port Mixed Gigabit SNMP 
Managed Switch

 

User’s Manual 

Содержание SNMP-FSH2602MG V2

Страница 1: ...SNMP FSH2602MG v2 24 2 port Mixed Gigabit SNMP Managed Switch User s Manual ...

Страница 2: ...anical photocopying or recording without the written consent of OvisLink Corp OvisLink Corp has made the best effort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change without notice All Trademarks are properties of their respective holders ...

Страница 3: ...g Rubber Feet 6 2 5 2 Rack mounted Installation 7 2 5 3 Power On 8 2 6 LED Table 8 3 Configuring the SNMP FSH2602MG v2 10 3 1 Important Information 10 3 2 Prepare your PC 10 3 3 Management Interface 11 3 4 Introduction to Web Management 14 3 4 1 Getting into Web Management 14 4 Web Management in SNMP FSH2602MG v2 16 4 1 Menu Structure of SNMP FSH2602MG v2 16 4 2 Port Status 17 4 3 Port Statistics ...

Страница 4: ...e 58 5 3 Main Menu 60 5 4 Function Description 61 5 4 1 Status and Counters 61 5 4 2 Switch Configuration 64 5 4 3 Protocol Related Configuration 85 5 4 4 System Reset Configuration 100 6 Application Example VLAN Network 107 6 1 Application Environment 107 6 2 VLAN Configuration 108 6 2 1 Configuration of Port Based VLAN 108 6 2 2 Configuration of 802 1Q VLAN 110 7 Application Example IGMP Snoopin...

Страница 5: ...Table of Contents iii AirLive SNMP FSH2602MG v2 User s Manual 8 3 Cabling 125 9 Specifications 126 10 Network Glossary 130 ...

Страница 6: ...fferent chapters You should read at least go through the first 3 chapters before attempting to install the device Recommended Reading Chapter 1 This chapter explains the basi information for SNMP FSH2602MG v2 It is a must read Chapter 2 This chapter is about hardware installation You should read through the entire chapter Chapter 3 3 1 Important Information This section has information of default ...

Страница 7: ...h latest information In addition you might find new firmwares that either increase software functions or provide bug fixes for SNMP FSH2602MG v2 You can reach our on line support center at the following link http www airlive com support support_2 jsp Since 2009 AirLive has added the Newsletter Instant Support System on our website AirLive Newsletter subscribers receives instant email notifications...

Страница 8: ...nction DHCP client supported Support Port Based VLAN 802 1Q VLAN IEEE802 3x Flow control z Flow control for full duplex z Backpressure for half duplex Support IEEE802 3ad Port trunk with LACP Broadcast storm filter supported Support IEEE 802 1p class of service Support Port security IEEE 802 1d Spanning tree protocol supported Auto detect Gigabit copper and MINI GBIC Support IEEE 802 1x user authe...

Страница 9: ... more details 2 1 Before You Start It is important to read through this section before you install the SNMP FSH2602MG v2 The maximum cabling distance is 100 meters Do not create a network loop Always check the LED lights for troubleshooting 2 2 Package Content Unpack the contents of the SNMP FSH2602MG v2 and verify them against the checklist below One unit of SNMP FSH2602MG v2 Power Cord Four Rubb...

Страница 10: ...al dealer for service 2 3 Optional Accessories The SNMP FSH2602MG v2 has the following optional accessories which you can purchase from AirLive 1000Base SX MiniGBIC Transceiver Model MGB SX or 1000Base LX MiniGBIC Transceiver Model MGB LX 10 is for your SFP slots of SNMP FSH2602MG v2 it allows you to use fiber cable for extending transmission distance Note While installing MiniGBIC into SFP slot o...

Страница 11: ... FSH2602MG v2 on a sufficiently large flat space with a power outlet nearby The surface where you put your SNMP FSH2602MG v2 should be clean smooth level and sturdy Make sure there is enough clearance around the SNMP FSH2602MG v2 to allow attachment of cables power cord and allow air circulation 2 5 1 Attaching Rubber Feet A Make sure mounting surface on the bottom of the SNMP FSH2602MG v2 is grea...

Страница 12: ...19 inch Rack The SNMP FSH2602MG v2 can be placed in a wiring closet with other equipment Perform the following steps to rack mount the SNMP FSH2602MG v2 A Position one bracket to align with the holes on one side of the SNMP FSH2602MG v2 and secure it with the smaller bracket screws Then attach the remaining bracket to the other side of the SNMP FSH2602MG v2 B After attached mounting brackets posit...

Страница 13: ... the rear panel of the SNMP FSH2602MG v2 The other side of power cord connects to the power outlet The internal power supply of the SNMP FSH2602MG v2 works with voltage range of AC in the 100 240VAC frequency 50 60Hz Check the power indicator on the front panel to see if power is properly supplied 2 6 LED Table The LED Indicators gives real time information of systematic operation status The follo...

Страница 14: ...mode FDX Off In half duplex mode 1000 Giga port 25 26 port Green In 1000Mbps connection speed 100 Giga port 25 26 port Orange In 100Mbps connection speed Green The port is connecting with the device Blink The port is receiving or transmitting data LNK ACT Giga port 25 26 port Off No device attached Orange The port is operating in Full duplex mode Blink Collision of Packets occurs in the port FDX C...

Страница 15: ...l help you to get start quickly However we recommend you to read through the entire manual before you start Please note the username and password are case sensitive The default IP address is 192 168 10 1 The default Subnet Mask is 255 255 255 0 The default Gateway is 192 168 10 254 The default username is airlive The default password is airlive 3 2 Prepare your PC The SNMP FSH2602MG v2 can be mana...

Страница 16: ...browser Most functions of SNMP FSH2602MG v2 can be accessed by web management inter face We recommend using this interface for initial configurations To begin simply enter SNMP FSH2602MG v2 s IP address default is 192 168 10 1 on the web browser The default username and password are airlive Console Management Terminal SNMP FSH2602MG v2 can be managed through terminal emulation program or Hyper Ter...

Страница 17: ...he airlive default value for the both User name and Password use Enter key to switch then press Enter key and the Main Menu of console management appears Please see below figure for login screen Telnet Management Terminal SNMP FSH2602MG v2 can be managed through telnet To use the telnet please open the command line windows Then type telnet Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow...

Страница 18: ...FSH2602MG v2 13 AirLive SNMP FSH2602MG v2 User s Manual 192 168 10 1 to start When asking for username and password please enter airlive Once entering username and password successfully you will see main menu of configuration ...

Страница 19: ...ased Management supports Internet Explorer 5 0 It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note By default IE5 0 or later version does not allow Java Applets to open sockets The user has to explicitly modify the browser setting to enable Java Applets to use network ports 3 4 1 Getting into Web Management We...

Страница 20: ...3 Configuring the SNMP FSH2602MG v2 15 AirLive SNMP FSH2602MG v2 User s Manual 5 Click Enter or OK then the home screen of the Web based management appears ...

Страница 21: ... in web management interface Please be sure to read through Chapter 3 s Introduction to Web Management first 4 1 Menu Structure of SNMP FSH2602MG v2 The web management menu of SNMP FSH2602MG v2 is divided into 3 parts Top Bar Side Menu Bar and Main Screen 4 4 Web Management in SNMP FSH2602MG v2 Side Menu Main Screen Top Bar ...

Страница 22: ...f manual Note You can click Help button when you have any configuration question during configuring 4 2 Port Status In Port status you can view every port status that depended on user setting and the negotiation result 1 Link Down is No Link UP is Link 2 State Display port statuses disable or enable Unlink will be treated as off 3 Auto Negotiation Display the auto negotiation mode auto force Nway ...

Страница 23: ...ured Actual means the current value of the port 7 Bandwidth Display the port incoming and outgoing bandwidth 8 Priority Display the port static priority status is High or Low or Disable 9 Port Security Display the port security is enable or disable 4 3 Port Statistics The following information provides a view of the current port statistic information Click Clear button to clean all counts ...

Страница 24: ... functions IP Configuration Switch Settings Console Port Information Port Controls Trunking Forwarding and Filtering VLAN Configuration Spanning Tree Port Mirroring SNMP Management Security Manager and 802 1x Configuration 4 4 1 IP Configuration User can configure the IP Settings and DHCP client function then clicks Apply button to apply your setting ...

Страница 25: ...unction SNMP FSH2602MG v2 will get IP address by DHCP server IP Address Assign the switch IP address The default IP is 192 168 10 1 Subnet Mask Assign the switch IP subnet mask The default IP is 255 255 255 0 Gateway Assign the switch gateway The default Gateway IP is 192 168 10 254 4 4 2 Switch Setting In this page it has three parts of setting Basic Advance and Misc Config We will describe the c...

Страница 26: ...e switch s firmware version Kernel Version Display the kernel software version Hardware version Display the switch hardware version MAC Address Display the unique hardware address assigned by AirLive Module Display the MiniGBIC information 4 4 2 2 Advanced In Advanced setting it has two sections MAC Table Address Entry and Priority Queue Service After configuring click Apply button to complete the...

Страница 27: ...nfigure MAC table aging time z Age out Time Fill in the number of seconds that an inactive MAC address remains in the Switch s address table The valid range is 300 765 seconds must be multiple of 3 The default is 300 seconds Max Bridge Transmit Delay Bound Limit the packets queuing time in Switch If enabled the packets whose queuing time exceed your setting will be dropped The valid value is 1sec ...

Страница 28: ...nd drops all broadcast traffic The valid threshold value is 5 10 15 20 25 and off Priority Queue Service settings There are many different applications users or data flows in a real network environment However the network capacity is limited you have to keep some network services in good performance such as real time streaming multimedia over IP or on line games Therefore you can use priority mech...

Страница 29: ...nsmit 96 bits of raw data on the medium which is 9 6 μs for 10 Mbit s Ethernet 960 ns for 100 Mbit s Fast Ethernet 96 ns for 1 Gbit s gigabit Ethernet Generally the interframe gap is not always 96 bit frames if it is less than 96 bit times it will occur that transmission speed of SNMP FSH2602MG v2 would be over 100 1000Mbps If SNMP FSH2602MG v2 transmit frames at a more than 100Mbps rate that caus...

Страница 30: ...allest IP address to be set for the IGMP Query mode b Enable Mode Enables the switch to be the IGMP Querier c Disable Mode Disables all other switches from being the IGMP Querier The following three topologies explain how IGMP Query works and to be configured within a network 1 Auto mode needs to be enabled when the router s IP address is smaller than other switches in the subnet ...

Страница 31: ...ut IGMP has to be enabled and the Router has to be the Querier 3 The following topology must be set when the IP address of the switch is not the smallest in the subnet The network will cause a multi cast storm from the IGMP client report if it is in Auto mode All switches must be in disable mode when the VOD server is configured for IGMP Querier Note It is suggested that the VOD server switch have...

Страница 32: ...umn 2 State User can disable or enable this port control 3 Negotiation User can set negotiation mode as Auto or Force on port 1 to port 24 and only Auto on port 25 and port 26 4 Speed User can set speed as 10Mbps or 100Mbps on port 1 to port 24 and only 1000Mbps on port 25 and port 26 5 Duplex Set Full Duplex or Half Duplex mode of the port When in Full Duplex mode user can configure Flow control ...

Страница 33: ...C addresses already existing in the address table can be forwarded normally User can disable the port from learning any new MAC addresses and then use the Static MAC addresses introduce in below pages function to define a list of MAC addresses that can use the secure port 11 Click Apply button to apply all configuration 12 When you select the port you can see port s current configuration value whi...

Страница 34: ...ng to the device that also supports LACP the LACP dynamic trunking group will be created automatically 4 Work ports Max four ports can be aggregated at the same time If it is LACP static trunk group the exceed ports are standby and able to aggregate if work ports fail If it is local static trunk group the number must be as same as the group member ports 5 Select the ports to join the trunk group M...

Страница 35: ...e aggregator with LACP disabled you will see related information in here Group Key It shows your Group ID Port member It show which ports are in this Group Key In below figure it shows that you have configured three Trunking groups Group 1 has member port 1 and 2 Group 2 has member port 4 5 9 and 13 Group 3 has member port 11 and 22 ...

Страница 36: ... sends LACP protocol packets 2 Passive The port does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device Note A link having either two active LACP ports or one active port can perform dynamic LACP trunking A link having two passive LACP ports will not perform dynamic LACP trunking because both ports are waiting for LACP proto...

Страница 37: ...explicitly joined It provides switches with a mechanism to prune multicast traffic from links that do not contain a multicast listener IGMP client A switch which does not IGMP snooping will by default flood multicast traffic to all the ports in a broadcast domain or the VLAN equivalent Multicast can cause unnecessary or even crippling load on host devices by requiring them to process packets they ...

Страница 38: ... Leave Group A message sent by a host to the querier to indicate that the host has quited to be a member of a specific multicast group When you enable IGMP Query refer to 4 2 2 3 and IGMP Snooping you will see the related information showed as below figure 4 4 6 2 Static MAC Address When you add a static MAC address it remains in the switch s address table regardless of whether the device is physi...

Страница 39: ...address please click the MAC address which you want to delete on the MAC address column and then click Delete button to delete it In the below figure it shows that you have created two static MAC address in the Switch They are 004f11111111 on port 1 without VLAN ID and 004f22222222 on port 8 without VLAN ID respectively 4 4 6 3 MAC filtering MAC filtering function allows the switch to drop unwante...

Страница 40: ...ilter in the switch They are 004f33333333 without VLAN ID and 004f44444444 without VLAN ID respectively 4 4 6 4 All MAC Addresses You can view the port that connected device s MAC address and the related devices MAC address 1 Select the port 2 The current static dynamic MAC address information of the port will be displayed in here 3 You also can click Clear MAC Table to clear the current MAC addre...

Страница 41: ... switch However all the network devices are still plug into the same switch physically The switch supports port based 802 1Q tagged based and protocol base VLAN in web management page In the default configuration VLAN support is disable 4 4 7 1 Port based VLAN Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the p...

Страница 42: ...User s Manual that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also other information about the packet such as the protocol 1 Click Add button then below screen will display You can create a new VLAN group ...

Страница 43: ...then click Add button to add members to right column 3 Click Apply button to apply your setting 4 After creating one VLAN you will see the VLAN group displays in main screen In the below figure it show that you have created one VLAN group whose Group name is Test1 and VLAN ID is 1 Choose port and then click Add button to add this port on VLAN group ...

Страница 44: ...IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers You can create Tag based VLAN and enable or disable GVRP protocol There are 256 VLAN groups provided to configure Enable 802 1Q VLAN the all ports on the switch belong to default VLAN VID is 1 The default VLAN can t be deleting GVRP allows automatic VLAN con...

Страница 45: ...otocol 4 VLAN ID Fill in a VLAN ID between 2 to 4094 The default is 1 5 Protocol VLAN Choose the protocol type Default is NONE 6 From the available port box select ports to add to the switch and click Add button If the trunk group exists you can see it on the bottom of the menu ex Trunk 1 and you can configure it as the member of the VLAN or not The default VLAN can t be deleting Check the check b...

Страница 46: ...Manual 7 Click Next button then you will see the page as below 8 To set the outgoing frames are VLAN Tagged frames or untagged Then click Apply button to apply your setting Tag outgoing frames with VLAN Tagged If the trunk group exists you can see it on the bottom of the menu ...

Страница 47: ...f the port belongs to that VLAN Enable Forward only packets with VID matching this port s configured VID Disable Disable Ingress filter function 3 Acceptable Frame type Tag Only Only packet with match VLAN ID can be permission to go through the port ALL Acceptable all Packet 4 VLAN ID Range Select a range of VLAN ID There are 16 VLAN ID range The ports are assigned to the same VLAN ID will be in t...

Страница 48: ... a priority of 10 then switch A will be selected as the root bridge because of smaller MAC address 2 Determine the least cost paths to the root bridge The lease cost path is a path from the device to the root that has minimum cost among all paths from the device to the root 3 Disable all other root paths Any active port that is not a root port or a designated port is a blocked port 4 Modification ...

Страница 49: ...ard delay time is defined as the time spent from Listening state moved to Learning state and also from Learning state moved to Forwarding state of a port in bridge The forward delay time contains two states Listening state to Learning state and Learning state to Forwarding state It assumes that forward delay time is 15 seconds and total forward delay time will be 30 seconds This has much to do wit...

Страница 50: ...sult may be half duplex in this case the port will not fast transit to Forwarding state If it is set as True the port is treated as point to point link by RSTP and unconditionally transited to Forwarding state If it is set as False fast transition to Forwarding state will not happen on this port The default is Auto 5 Assign the Admin Edge If user selects True this port will be an edge port An Edge...

Страница 51: ...ring is a method for monitoring traffic in switched networks Traffic through ports can be monitored by one specific port That is traffic goes in or out monitored ports will be duplicated into mirror port 1 Port Mirroring State User can select Disable RX TX and Both You also can configure spanning tree on trunk group ...

Страница 52: ...ored port traffic will be copied to mirror port You can select max 25 monitor ports in the switch User can choose which port wants to monitor in only one mirror mode Note If you want to disable the function you must select monitor port to none If the trunk group exists you can see it in port menu ex Trunk 1 and you also can configure it for port mirroring configuration If the trunk group exists yo...

Страница 53: ... a password between trap manager and switch String Fill the name of string RO Read only Enable requests accompanied by this string to display MIB object information RW Read write Enable requests accompanied by this string to display MIB object information and to set MIB objects Once entering the above information please click Add button to add your new string If you want to remove one string pleas...

Страница 54: ...ge web management login user name and password User name Type the new user name The default is airlive Password Type the new password The default is airlive Confirm password Re type the new password to confirm your new password After changing the above information please click Apply button to apply your setting 1 2 3 ...

Страница 55: ...r Port Set the UDP destination port for authentication requests to the specified Radius Server 3 Accounting Port Set the UDP destination port for accounting requests to the specified Radius Server 4 Shared Key Set an encryption key for use during authentication sessions with the specified radius server This key must match the encryption key used on the Radius Server 5 NAS Identifier Set the identi...

Страница 56: ...n the Authorized state Authorized The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server Disable The specified port did not support 802 1x function 3 Click Apply button to apply your setting You can see the every port Authorization information listed in table Note If the tru...

Страница 57: ...lid range is 1 to 65535 The default time is 60 seconds 2 TX period Set the period the port waits to re transmit next EAPOL PDU during an authentication session The valid range is from 1 to 65535 The default time is 30 seconds 3 Supplicant timeout Set the period of time the switch waits for a supplicant response If the trunk group exists you can see it and configure it for 802 1x configuration ...

Страница 58: ...sion ends The valid range is from 1 to 10 The default value is 2 times 6 Reauth period Set the period of time after which clients connected must be re authenticated The valid range is from 1 to 99999 The default value is 3600 seconds 4 5 TFTP Update Firmware It provides the functions to allow a user to update the switch firmware Before updating make sure you have your TFTP server ready and the fir...

Страница 59: ... server TFTP Restore Configuration You can restore EEPROM value from TFTP server but you must put back image in TFTP server switch will download back flash image 1 TFTP Server IP Address fill in the TFTP server IP 2 Restore File Name fill in the correct restore file name 3 Click Apply button to restore configuration file TFTP Backup Configuration You can save current EEPROM value from the switch t...

Страница 60: ...age bin 3 Click Apply button to restore configuration file 4 7 Factory Default Reset Switch to default configuration default value to as following configuration Default IP address 192 168 10 1 Default Gateway 192 168 10 254 Subnet mask 255 255 255 0 The other setting value is back to disable or none Click Default button to reset switch to default setting Once resetting to factory default successfu...

Страница 61: ...cking function beware the following points Any port on the switch can be used to stack Before configuring the stacking function make sure all stack switches are in the same network When configure stacking function please must configure the master switch first After stacking group has set up all slave switches are configured through master switch You still can directly access to slave switch but al...

Страница 62: ...D The valid range is from 1 to 65535 3 Stacking Mode Select the stacking mode from drag down list Disable It means the switch doesn t belong to any stacking group or stacking function is disabled Master It means the switch is the leader master in the stacking group The master switch can control all the slave switches in stacking group Slave it means the switch is a slave switch of the stacking gro...

Страница 63: ...ale DB 9 connector that enables a connection to a PC or terminal for monitoring and configuring the Switch Use the supplied RS 232 cable with a male DB 9 connector to connect a terminal or PC to the Console port 5 2 Login in the Console Interface When the connection between Switch and PC is ready turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication ...

Страница 64: ...blank screen shows up press Enter key to bring out the login prompt Key in the airlive default value for the both User name and Password use Enter key to switch then press Enter key and the Main Menu of console management appears Please see below figure for login screen Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None ...

Страница 65: ...l Related Configuration Configure the protocol function System Reset Configuration Restart the system or reset switch to default configuration Logout Exit the menu line program Control Key description The control keys provided in all menus Tab Move the vernier to next item Backspace Move the vernier to previous item Enter Select item Space Toggle selected item to next configure or change the value...

Страница 66: ...tatus of the port Select the Previous Page action to display previous page And select the Next page action to display next page Type Display port connection speed type Link Display port link status When the port is connecting with the device and work normally the link status is UP Opposite is Down State The port current status Enable it means this port working status is normal Disable it means thi...

Страница 67: ...pressure status Bandwidth In Out Display bandwidth In out control status Priority Display the port priority status Security Display the port security status Port Counters It will display the current port counter information Select the Refresh action to get newest port counter information Select the Clear action to set the port counter information back to 0 ...

Страница 68: ...tem Location where the device is located 3 System Description the name of device type 4 Firmware Version the switch s firmware version 5 Hardware Version the switch s Hardware version 6 Kernel Version the system kernel software version 7 MAC Address The unique hardware address assigned by manufacturer 8 Module Information display the Module type that you have installed in switch ...

Страница 69: ...User s Manual 64 5 4 2 Switch Configuration In Switch Configuration it has 8 main functions Administration Port Trunk Port Mirroring VLAN Priority MAC Address and Misc Configuration Under each function there are more sub functions We will describe in following paragraph ...

Страница 70: ...tion system parameter IP login username and password Device Information You can configure the device information 1 Select Edit action to configure 2 Name assign the name for the switch 3 Description a short description for the switch 4 Location the switch location ex Taipei 5 Contact the contact person or information 6 Select Save action to save the configuration ...

Страница 71: ...nfigure or use the default value 1 Select the Edit 2 DHCP Disable or enable the DHCP client function 3 IP Address Assign the switch IP address The default IP is 192 168 16 1 4 Subnet Mask Assign the switch IP subnet mask 5 Gateway Assign the switch gateway The default value is 192 168 16 254 6 Select Save action to save the configuration Note Always restart the switch after finished the setup ...

Страница 72: ...ement in SNMP FSH2602MG v2 67 AirLive SNMP FSH2602MG v2 User s Manual Username Configuration You can change the console and web management login user name 1 Select the Edit 2 Enter the new user name 3 Select the Save ...

Страница 73: ...the new password 4 Enter Again reenter the new password for confirmation 5 Select the Save Port Configuration You can set up every port status 1 Select Edit 2 Use Tab key to move between items 3 State Current port status The port can be set to disable or enable mode If the port setting is disable then will not receive or transmit any packet 4 Negotiation set auto negotiation status of port 5 Speed...

Страница 74: ... control Per level is 100Kbps It supports individual control method of TX and RX 9 Priority set port to high or low priority 10 Security enable or disable port security function 11 Select the Save Trunk Configuration You can configure port trunk group 1 Select Edit 2 Using Tab key move to the port that want to be added into trunk group 3 Using Space key to mark the port as 4 Using Tab key move to ...

Страница 75: ...works The specific port can monitor traffic through the mirror ports The monitored ports in or out traffic will be duplicated into monitoring port 1 Select the Edit 2 Mirroring State Select the port mirroring mode The default value is Disable To start port mirroring you must select one of port mirroring mode RX RX packet only TX TX packet only Both RX and TX packet ...

Страница 76: ... port of mirroring packet All of the packets of mirroring port will be duplicated and sent to Analysis port 4 Use Space key to mark the mirroring port 5 Select the Save When Mirroring state is in Disable it will not show any port state When Mirroring state is in Tx Rx or Both it will show port state for user to configure ...

Страница 77: ...e user cannot create any new VLAN 1 Select the Edit 2 Select the VLAN mode by using Space key There are two VLAN modes Port Based mode and 802 1Q mode 802 1Q VLAN mode configuration VLAN ID Ingress Filter and Acceptable Frame Type z VLAN ID Port VID 1 255 Type the PVID z Ingress Filter It matches that Ingress Filtering Rule 1 on web Only forward packets with VID matching this port s configured VID...

Страница 78: ... VLAN group ID The group ID rang is from 1 to 4094 4 Member Press Space key to change the member value There are two types to selected a Member the port is a member port b NO it means that the port is NOT a member port 5 Press ESC key to go back action menu line 6 Select Save to save the configuration NOTE If you had configured the trunk groups you can see it ex Trunk 1 Trunk 2 in the port list Yo...

Страница 79: ...enable security VLAN group only the members in this VLAN group can access to the switch The steps of setting security VLAN refer to the following step 2 8 After you have configured the security VLAN group you can continue to create other VLAN groups When you don t select to configure security VLAN group then just create VLAN group refer to following step 2 8 Note There is only one security VLAN gr...

Страница 80: ...5 Protocol VLAN Press Space key to choose protocols type 6 Member Press Space key to change the member value Untagged this port is the member port of this VLAN group and outgoing frames are NO VLAN Tagged frames Tagged this port is the member port of this VLAN group and outgoing frames are VLAN Tagged frames NO it means that the port is NOT member of this VLAN group 7 Press ESC key to go back acti...

Страница 81: ...e VLAN group that you want to edit or delete then press enter 3 In Edit action user can modify the member port and remove member ports from this VLAN group 4 After edit or delete the VLAN select Save action to save all configures value NOTE 1 The VLAN Name and VLAN ID cannot modify 2 In 802 1Q VLAN mode the default VLAN can t be deleted 3 In Port Base VLAN mode there is no default VLAN ...

Страница 82: ...77 AirLive SNMP FSH2602MG v2 User s Manual Group Sorted Mode You can select VLAN groups sorted mode Name or VLAN ID In the Edit Delete a VLAN group page will display the result 1 Select Edit 2 Use Space key to select the sort mode 3 Select Save ...

Страница 83: ...ket priority is low Weight Round Ration 2 1 the switch will process 2 high priority packets first the process 1 low priority packet Weight Round Ration 3 1 the switch will process 3 high priority packets first the process 1 low priority packet Weight Round Ration 4 1 the switch will process 4 high priority packets first the process 1 low priority packet Weight Round Ration 5 1 the switch will proc...

Страница 84: ...e Management in SNMP FSH2602MG v2 79 AirLive SNMP FSH2602MG v2 User s Manual MAC Address Configuration In MAC Address Configuration you can configure Static MAC Address Filtering MAC Address and All MAC Address ...

Страница 85: ...te a static MAC address Add the Static MAC Address You can add static MAC address in switch MAC table 1 Select Add Æ Edit key to add the static MAC address 2 MAC Address Enter the MAC address of the port that should permanently forward traffic regardless of the device network activity 3 Port No Press Space key to select the port number 4 VLAN ID Enter the Mac address s VLAN ID if the Mac address b...

Страница 86: ...y to modify 4 Press ESC to go back action menu line 5 Select Save to save all configure value Delete static MAC address 1 Select Delete key 2 Choose the MAC address that you want to delete and then press Enter 3 When pressing Enter will complete deletion Filtering MAC Address You can add delete and edit filtering MAC address Add the Filtering MAC Address 1 Select Add Æ Edit key to add the static M...

Страница 87: ...action menu line 5 Select Save to save all configure value Edit Filtering MAC address 1 Select Edit key to modify a static Filtering address 2 Choose the MAC address that you want to modify and then press Enter 3 Select Edit key to modify 4 Press ESC to go back action menu line 5 Select Save to save all configure value Delete Filtering MAC address 1 Select Delete key to delete a Filtering MAC addr...

Страница 88: ...he control of the switch in the network For the manager personal he she can save the time and easily on switches controlling MAC Address Ageing Time MAC address table refresh time setting Type the number of seconds that an inactive MAC address remains in the switch s address table The valid range is 0 300 765 seconds Default is 300 seconds Broadcast Storm Filter mode configure the broadcast storm ...

Страница 89: ... or Enable IP Stacking Group ID 0 65535 assign the stacking group ID The switches must assign the same stacking group ID to be stacked as a group IP Stacking Mode enabling disabling the stacking function There are three stacking modes Any port on the switch can be used to stack To configure the switch in stacking group please use the Web GUI configuration interface z Disable The stacking function ...

Страница 90: ...ment in SNMP FSH2602MG v2 85 AirLive SNMP FSH2602MG v2 User s Manual 5 4 3 Protocol Related Configuration You can configure Spanning Tree Protocol SNMP LACP IGMP GVRP and 802 1x in Protocol Relate Configuration section ...

Страница 91: ...figuring RSTP function 1 Select Edit 2 Use Space key to select the option User can select RSTP Disable or STP 3 Select Save System Configuration You can configure the RSTP system parameter after enable the RSTP function You can view spanning tree information about the Root Bridge on the left 1 Select Edit 2 Priority Assign path priority number The valid value is 0 61440 The default is 32678 3 Max ...

Страница 92: ... become the root port The valid value is from 0 to 255 The lowest value has higher priority The default is 128 Admin P2P There are three parameters Auto True and False used to configure the type of the point to point link If configuring this parameter to be Auto it means RSTP will use the duplex mode resulted from the auto negotiation In today s switched networks most links are running in full dup...

Страница 93: ...the STP topology keeps unchanged Unlike the designate port or root port though an edge port will transit to a normal spanning tree port immediately if it receives a BPDU The default is True 4 Admin Non Stp The port includes the STP mathematic calculation True is not including STP mathematic calculation False is including the STP mathematic calculation The default is False 5 Press ESC goes back act...

Страница 94: ... in SNMP FSH2602MG v2 89 AirLive SNMP FSH2602MG v2 User s Manual SNMP To define management stations as trap managers and to enter SNMP community strings You can also define a name location and contact person for the switch ...

Страница 95: ... Press ESC goes back action menu line 6 Press Save to save configured value Community Strings Add Community Strings 1 Select Add 2 Select Edit 3 Community Name Type the name of community strings 4 Write Access Enable the rights is read only or read write z Read only Read only enables requests accompanied by this string to display MIB object information z Read Write Read write enables requests acco...

Страница 96: ...2 91 AirLive SNMP FSH2602MG v2 User s Manual Edit Community Name 1 Select Edit 2 Choose the item that you want to modify and then press Enter 3 Community Name type the new name 4 Write Access Press Space key to change the right 5 Select Save ...

Страница 97: ...2 Choose the community name that you want to delete and then press Enter Trap Managers A trap manager is a management station that receives traps the system alerts generated by the switch If no trap manager is defined no traps will issue Create a trap manager by entering the IP address of the station and a community string ...

Страница 98: ...MP FSH2602MG v2 User s Manual Add the trap manager 1 Select Add Æ Edit to add the trap manager 2 IP enter the IP address of trap manager 3 Community Name enter the community string 4 Press ESC go back to actions menu line 5 Select Save to save all configure ...

Страница 99: ... Aggregation Group to which the link belongs move the link to that Link Aggregation Group and enable its transmission and reception functions in an orderly manner Link aggregation lets you group up to eight consecutive ports into a single dedicated connection This feature can expand bandwidth to a device on the network LACP operation requires full duplex mode more detail information refers to IEEE...

Страница 100: ... work ports fail If it is local static trunk group the number must be the same as group ports 5 Select Save NOTE Before set LACP support you have to set trunk group on the Trunk Configuration LACP State Activity 1 Select Edit 2 Use Space key to select the Port State Activity Active The port automatically sends LACP protocol packets Passive The port does not automatically send LACP protocol packets...

Страница 101: ...5 Console Management in SNMP FSH2602MG v2 AirLive SNMP FSH2602MG v2 User s Manual 96 Group Status When setting trunk group you can see the relation information in here ...

Страница 102: ...NMP FSH2602MG v2 97 AirLive SNMP FSH2602MG v2 User s Manual IGMP GVRP You can enable or disable the IGMP GVRP GARP VLAN Registration Protocol 1 Select Edit 2 Use Space key to change the value 3 Select Save 802 1x Configuration ...

Страница 103: ...2 Radius Server IP set the Radius Server IP address 3 Shared Key set an encryption key for using during authentication sessions with the specified radius server This key must match the encryption key used on the Radius Server 4 NAS Identifier set the identifier for the radius client 5 Server Port set the UDP destination port for authentication requests to the specified Radius Server 6 Accounting P...

Страница 104: ...SH2602MG v2 99 AirLive SNMP FSH2602MG v2 User s Manual Per Port Configuration You can configure 802 1x authentication state for each port The State provides Disable Accept Reject and Authorize Use Space key to change the state value ...

Страница 105: ...ime the switch waits for a supplicant response to an EAP request 5 Server Timeout set the period of time the switch waits for a server response to an authentication request 6 Reauthorize Maximum set the number of authentication that must time out before authentication fails and the authentication session ends 7 Reauthorize period set the period of time after which clients connected must be re auth...

Страница 106: ...H2602MG v2 101 AirLive SNMP FSH2602MG v2 User s Manual Factory Default Reset switch to default configuration 1 Press Y switch will load default setting 2 The below figure will tell user that it is restoring to factory default setting ...

Страница 107: ...ive SNMP FSH2602MG v2 User s Manual 102 3 After finished load default setting switch will reboot automatically The rebooting process will display as below System Reboot Reboot the switch in software reset The rebooting process will display as below ...

Страница 108: ...5 Console Management in SNMP FSH2602MG v2 103 AirLive SNMP FSH2602MG v2 User s Manual TFTP Configuration It provides user to update firmware or restore EEPROM value or upload current EEPROM value ...

Страница 109: ...IP of TFTP server 4 Firmware File Name type the image file name 5 Press ESC to back to action line 6 Select Save the system will start to download the image file 7 When save successfully the image file download finished too 8 Restart switch TFTP Restore Configuration You can restore EEPROM value which saved in TFTP server from TFTP server 1 Start the TFTP server 2 Select Edit 3 TFTP Server IP type...

Страница 110: ...rt switch TFTP Backup Configuration You can save current EEPROM value to TFTP server as backup The backup file can be restored from TFTP server when you need 1 Start the TFTP server 2 Select Edit 3 TFTP Server IP type the IP of TFTP server 4 Backup File Name type the image file name 5 Press ESC back to action line 6 Select Save key it will start to upload the image file 7 When save successfully th...

Страница 111: ...5 Console Management in SNMP FSH2602MG v2 AirLive SNMP FSH2602MG v2 User s Manual 106 ...

Страница 112: ...epartment R D department These departments can share the same company resource such as ERP system print server Here is one simple example for users to use VLAN function well The organization structure of Company A is below Company A has tree main departments Sales department R D department and Administration department Members in different departments can share the same network resource such as ER...

Страница 113: ... in detail The basic consumption is below ERP server data center or some shared servers are connected to port 25 and port 26 respectively R D department can use port 1 to port 8 Sales department can use port 9 to port 16 Administration department can use port 17 to port 24 Departments cannot communicate each other but can access ERP server and data center 6 2 1 Configuration of Port Based VLAN Ste...

Страница 114: ...rt 26 Click Apply button to create your VLAN group Step 3 Follow Step 2 to create another two VLAN groups The detailed setting is below z Group name R D VLAN ID 10 member ports port 1 to 8 port 25 port 26 z Group name Sales VLAN ID 20 member ports port 9 to 16 port 25 port 26 z Group name Admin VLAN ID 30 member ports port 17 to 24 port 25 port When selecting Port Based mode the configuration page...

Страница 115: ...er s Manual 110 26 The result of VLAN configuration will display as below After finishing above steps the Tag VLAN function can work as your need 6 2 2 Configuration of 802 1Q VLAN Step 1 Select VLAN operation mode to 802 1Q then the configuration page will display ...

Страница 116: ...VLAN group whose group name is R D VLAN is 10 member ports are port 1 to port 8 port 25 and port 26 Click Next button to configure other settings Step 3 While clicking Next button user does need to any change on this page When selecting 802 1Q mode the configuration page will display The default VLAN can t be deleting ...

Страница 117: ...another three VLAN group The detailed setting is below z Group name R D VLAN ID 10 member ports port 1 to 8 port 25 port 26 z Group name Sales VLAN ID 20 member ports port 9 to 16 port 25 port 26 z Group name Admin VLAN ID 30 member ports port 17 to 24 port 25 port 26 The result of VLAN configuration will display as below ...

Страница 118: ...rt 1 to port 8 in port menu enter Port VLAN ID as 10 and select VLAN ID Range to 1 255 Then click Apply button to apply your setting Step 6 Follow Step 6 the detailed setting is below z Port 1 to 8 Port VLAN ID is 10 VLAN ID Range is 1 255 z Port 9 to 16 Port VLAN ID is 20 VLAN ID Range is 1 255 z Port 17 to 24 Port VLAN ID is 30 VLAN ID Range is 1 255 ...

Страница 119: ...this application example user can easily know advantage of IGMP Snooping 7 1 Application Environment A network designed to deliver a multicast service like video using IGMP might use this basic network structure For easily understanding how IGMP Snooping works in SNMP FSH2602MG v2 we simplify the above structure We use one PC as video server two PCs as video clients SNMP FSH2602MG v2 connects them...

Страница 120: ...MG v2 via RJ 45 cable and video client connects to port 13 of SNMP FSH2602MG v2 via RJ 45 cable 7 2 Configuration of video server and client Before following the above steps please install VLC media server in advance Please refer to www vidoelan org for better knowing 7 2 1 Video Server Step 1 Execute VLC and click File Wizard Step 2 Check Stream to network and then click Next ...

Страница 121: ...IGMP Snooping AirLive SNMP FSH2602MG v2 User s Manual 116 Step 3 Check Select a stream and then click Choose to choose your media files which will be played Step 4 In this page choose one media file and then click OK button ...

Страница 122: ...ng 117 AirLive SNMP FSH2602MG v2 User s Manual Step 5 After entering directory of media file and then click Next to do next step Step 6 Check RTP Multicast to enter multicast address of video server and then click Next to do next step ...

Страница 123: ...e IGMP Snooping AirLive SNMP FSH2602MG v2 User s Manual 118 Note IP range of multicast address must be between 224 0 0 0 and 239 255 255 255 Step 7 Check encapsulation format as you want and then click Next to do next step ...

Страница 124: ...7 Application Example IGMP Snooping 119 AirLive SNMP FSH2602MG v2 User s Manual Step 8 Enter TTL as your need and then click Finish to finish configuration of video server ...

Страница 125: ...2 Video client Video clients are interested in content of group 239 1 1 1 so they can join group 239 1 1 1 via multicast to view the video Step 1 Execute VLC and click File Wizard Step 2 Check UDP RTP Multicast and enter IP address and port number of video server Then click OK to finish configuration of video client Set Loop to repeatedly play ...

Страница 126: ...7 Application Example IGMP Snooping 121 AirLive SNMP FSH2602MG v2 User s Manual Step 3 VLC media player will play multimedia file from 239 1 1 1 IP address of video server ...

Страница 127: ... click Administrator Forwarding and Filtering IGMP Snooping From WebUI user can know that video client port 13 joins multicast group 239 1 1 1 and there is one multicast group connecting port 9 With snooping function Switch can easily know that when receiving packets from multicast group 239 1 1 1 it just only transmits packets to port 13 does not need transmit packets to other ports it will reduc...

Страница 128: ...7 Application Example IGMP Snooping 123 AirLive SNMP FSH2602MG v2 User s Manual ...

Страница 129: ...lty connections If they appear to be OK make sure the connections are snug IF that does not correct the problem try a different cable Non standard cables Non standard and miss wired cables may cause numerous network collisions and other network problem and can seriously impair network performance A category 5 cable tester is a recommended tool for every 100Base T network installation Improper Netw...

Страница 130: ...utlet or power cord However if the Switch powers off after running for a while check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance 8 3 Cabling RJ 45 ports use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Ω Category 3 4 or 5 cable for 10Mbps connections or 1...

Страница 131: ...T z IEEE802 3x Flow Control and Back pressure z IEEE802 3ad Port trunk with LACP z IEEE802 1d Spanning tree protocol z IEEE802 1p Class of service z IEEE802 1Q VLAN Tagging z IEEE802 1w Rapid Spanning tree protocol Interface z 24 x 10 100Mbps Auto negotiation Auto MDIX ports z 2 x 1000Base T mini GBIC ports combo Switch architecture z Store and forward switch architecture z Back plane up to 8 8Gbp...

Страница 132: ...rap RFC 2674 VLAN MIB private MIB z SNMP Trap Cold start link down link up authorization fail Trap station up to 3 z TFTP and Console firmware upgradeable z Port Trunk Support IEEE802 3ad with LACP function Up to 7 trunk groups and group member up to 4 Trunk port within 24 port 10 100TX and 2 Ext Gigabit port z Supports IEEE802 1d STP IEEE802 1w RSTP z VLAN Port based VLAN IEEE802 1Q Tag VLAN GVRP...

Страница 133: ...gress MAC address filter and static source MAC address lock z Supports Port Mirroring z Supports Broadcast Storm Control z Supports Bandwidth Control per level 100Kbps z Supports 802 1x Authentication Reject Accept Authorize Disable z Support DHCP client z Supports Broadcast storm filter MTBF z 39797 78863 hr Temperature z Operating 0 to 40 C z Storage 10 to 70 C Humidity z Operating 10 90 z Stora...

Страница 134: ...9 Specifications 129 AirLive SNMP FSH2602MG v2 User s Manual Dimensions z 440 x 161 x 44 mm ...

Страница 135: ...s 10 BaseT standard 1000Base SX Also known as 802 3z The IEEE standard defines how to transmit gigabit Ethernet data using multi mode fiber optic cables This standard allows transmission distance of 550 meter which is more than 5 times longer than the 100 meter limitation of 1000Base T The 1000Base SX cannot run in 100Mbps mode 1000Base LX The IEEE standard defines how to transmit gigabit Ethernet...

Страница 136: ... in frames of 256 ID at a time 802 1x 802 1x is a security standard for wired and wireless LANs In the 802 1x parlance there are usually supplicants client authenticator switch or AP and authentication server radius server in the network When a supplicants request a service the authenticator will pass the request and wait for the authentication server to grant access and register accounting The 80...

Страница 137: ...r a multicast group they have not explicitly joined It provides switches with a mechanism to prune multicast traffic from links that do not contain a multicast listener IGMP client IP Address IP Internet Protocol is a Layer 3 network protocol that is the basis of all Internet communication An IP address is 32 bit number that identifies each sender or receiver of information that is sent across the...

Страница 138: ...onal SFP optical transceiver Packet A unit of data sent over a network Rate Control It is an Ethernet switch s function to control the upstream and downstream speed of an individual port Rate control management use Flow Control to limit the speed of a port Therefore the Ethernet adapter must also have the flow control enabled One way to force the adapter s flow control on is to set a port to half ...

Страница 139: ...rforming a BIT wise AND operation between the IP address and the subnet mask By changing the subnet mask you can change the scope and size of a network TFTP Trivial File transfer Protocol A file transfer protocol with the functionality of a very basic form of FTP It is used to transfer small amounts of data between hosts on a network such as Switch firmware ...