AirLive SI-102 Скачать руководство пользователя страница 9

 

8

Specifications

 

 

Power by CR123A lithium battery. 

Signal (Frequency): 

868.40 MHz, 869.85 MHz(EU), 

908.40 MHz, 916.00 MHz(US), 

922~927 MHz(JP/TW), 

921.40 MHz, 919.80 MHz(ANZ), 

869.00 MHz(RU), 

865.20 MHz(IN), 

916.00 MHz(IL), 

Range: 

Minimum 40 meters indoor, 

100 meters outdoor line of sight. 

 

RF Maximum Power: +5dBm 
Operating Temperature: -10oC ~ 40oC 

For indoor use only. 

 

Specifications subject to change without notice due to continuing 

product improvement.

 

 

 

 

 

 

OvisLink Corp., 

http://www.airlive.com/

 

 
TEL: +886 2 2218 6888 
FAX: +886 2 2918 6988 

 

 

                                   

 

FCC ID: ODMSI102

 

Содержание SI-102

Страница 1: ...2 Motion Report 3 Tamper Report 3 Timing Report 3 Power Up Procedure 3 Battery Power Check 3 PIR Warm Up 3 NWI 4 Wake 4 Security Network 4 Operation Mode 4 Choosing a Suitable Location 4 Z Wave Configuration Settings 5 Z Wave Supported Command Class 5 Specifications 8 FCC Interference Statement 9 Warning 9 ...

Страница 2: ...aveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Adding to Remove from Z WaveTM Network There are two keys in the device one is t...

Страница 3: ... nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the button one time to abort the NWI mode Z WaveTM Notification After the device a...

Страница 4: ...us Battery level report Every 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes will report once Notice The configuration NO 10 could be setting to zero to disable the auto report And the configuration NO 20 could change the tick interval the default value is 30 if setting to 1 that means the ...

Страница 5: ...and Normal Test Mode is for the user test the sensor function when installation Normal Mode is for the normal operation Operation Mode can be switched by pressing tamper key three times LED can indicate which mode it is Lighting on one second means entering test mode flashing once means entering normal mode When the event triggered normally the LED won t indicated unless the battery is in the low ...

Страница 6: ..._POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY No Name Def Valid Description 2 Basic Set Level 1 All Setting the BASIC command value to turn on the light 1 0xFF means turn on the light For dimmer equipment 1 to 100 means the light strength 0 means turn off the light Caution The range is from 0x00 0xFF using hexadecimal notation 3 PIR Sensitivity 80 0 ...

Страница 7: ...Enable Note Depends on the Bit4 0 Report Notification CC Type 0x07 Event 0xFE 1 Sensor Binary Report Type 0x0C Value 0x00 1 Bit2 Enable PIR super sensitivity mode 0 Disable 1 Enable 0 Bit3 Reserve 0 Bit4 Notification Type 0 Using Notification Report 1 Using Sensor Binary Report 0 Bit5 Disable Multi CC in auto report 1 Disable 0 Enable 0 Bit6 Disable to report battery state when the device triggere...

Страница 8: ...2 0 127 The interval time for auto report the battery level 0 means turn off auto report battery The default value is 12 The tick time can setting by the configuration No 20 20 Auto Report Tick Interval 30 128 127 The interval time for auto report each tick Setting this configuration will effect configuration No 10 The unit is 1 minute Caution1 Setting to 0 means turn off all auto report function ...

Страница 9: ...NZ 869 00 MHz RU 865 20 MHz IN 916 00 MHz IL Range Minimum 40 meters indoor 100 meters outdoor line of sight RF Maximum Power 5dBm Operating Temperature 10oC 40oC For indoor use only Specifications subject to change without notice due to continuing product improvement OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6988 FCC ID ODMSI102 ...

Страница 10: ...at to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or mo...

Отзывы: