6
0
Bit3: When Bit2 is 0 (Enable), Are the device and the lighting in
the same room?
0: In the same room (Default), 1: In the different room.
0
Bit4: Disable delay 5 seconds to turn off the light, when
door/window closed. (1:Disable, 0:Enable)
0
Bit5: Disable auto turn off the light, after door/window opened
to turn on the light. (1:Disable, 0:Enable)
Notice: If bit2 is zero, this setting is useless. Notice: If the
0
Bit6: Reserve.
0
Bit7: Reserve.
No.
Name
Def.
Valid
Description
7 (*)
Customer
Function
4
All
Customer function switch, using bit control. Caution: The range is
from 0x00~0xFF using hexadecimal notation.
0
Bit0: Reserve.
0
Bit1: Enable sending motion OFF report. (0:Disable, 1:Enable)
Note: Depends on the Bit4,
0: Report Notification CC, Type: 0x07, Event:
0xFE
1: Sensor Binary Report, Type: 0x0C, Value: 0x00
1
Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable)
0
Bit3: Reserve.
0
Bit4: Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.
0
Bit5: Disable Multi CC in auto report.
(1:Disable, 0:Enable)
0
Bit6: Disable to report battery state when the device triggered.
(1:Disable, 0:Enable)
0
Bit7: Reserve.
8
PIR Re-
Detect
Interval Time
3
1~127
In the normal mode, after the PIR motion detected, setting the
re-detect time. 8 seconds per tick, default tick is 3 (24 seconds).
Setting the suitable value to prevent received the trigger signal too
frequently. Also can save the battery energy.
Notice: If this value bigger than the configuration setting NO. 9.
There is a period after the light turned off and the PIR not start
detecting.