background image

2

3

NOTE TO PHYSICIAN: Injection in the skin is a traumatic 
injury. It is important to treat the injury surgically as soon as 
possible. DO NOT DELAY treatment to research toxicity. Tox-
icity is a concern with some exotic coatings injected directly 
into the blood stream. Consultation with a plastic surgeon or 
reconstructive hand surgeon may be advisable.

FLUIDS UNDER HIGH PRESSURE FROM SPRAY OR 

LEAKS CAN PENETRATE THE SKIN AND CAUSE 

EXTREMELY SERIOUS INJURY, INCLUDING THE 

NEED FOR AMPUTATION.

NEVER 

point the spray gun towards anyone or at any part 

of the body.

NEVER 

put hand or fingers over the spray tip. Do not use 

rag or other materials over your fingers. Paint will penetrate 

through material and into the hand.

NEVER 

try to stop or deflect leaks with your hand or body.

ALWAYS 

have gun tip guard in place when spraying.

ALWAYS 

lock gun trigger when you stop spraying.

ALWAYS 

remove tip from the gun to clean it.

NEVER 

try to "blow back" paint, it’s not an air sprayer.

ALWAYS 

follow the

 PRESSURE RELIEF PROCEDURE,

 

as shown on page 8, before cleaning or removing the spray 

tip or servicing any system equipment.

Be sure equipment safety devices are operating properly 

before each use.

ALWAYS 

tighten all fluid connections before each use.

If any fluid appears to penetrate your skin, get 

EMERGENCY CARE AT ONCE. 

DO NOT TREAT AS A SIMPLE CUT.

• Go to an emergency room immediately.

• Tell the doctor you suspect an injection injury.

• Tell him what kind of material you were spraying with and 

have him read 

NOTE TO PHYSICIAN

 above.

NEVER 

alter equipment in any manner.

NEVER 

smoke while in spraying area.

NEVER 

spray highly flammable materials.

NEVER 

use around children.

NEVER 

allow another person to use sprayer unless he is 

thoroughly instructed on its' safe use and given this 

operators manual to read.

ALWAYS 

wear a spray mask, gloves and protective eye 

wear  while spraying. 

ALWAYS 

ensure fire extinquishing equipment is readily 

available and properly maintained.

NEVER LEAVE SPRAYER UNATTENDED WITH 

PRESSURE IN THE SYSTEM. FOLLOW PRESSURE 

RELIEF PROCEDURES ON PAGE 8.

Keep spraying area free from obstructions.

Make sure area has good ventilation to safely remove 

vapors. 

NEVER 

keep flammable material in spraying area.

NEVER 

spray in vicinity of open flame or other sources of 

ignition. Spraying area must be at least 20 ft. away from 

spray unit.

HIGH PRESSURE SPRAY CAN CAUSE EXTREMELY SERIOUS INJURY. OBSERVE ALL 

WARNINGS. THIS SPRAYER IS FOR PROFESSIONAL USE ONLY.

ALWAYS 

set safety lock on the gun in "

LOCKED

" position 

when not in use and before servicing or cleaning. 

DO NOT 

remove or modify any part of gun.

ALWAYS 

remove spray tip when cleaning. 

Flush unit with 

LOWEST POSSIBLE PRESSURE.

CHECK 

operation of all gun safety devices before each 

use. Be very careful when removing the spray tip or hose 

from gun. A plugged line contains fluid under pressure. If 

the tip or line is plugged, follow the 

PRESSURE RELIEF 

PROCEDURE 

as outlined on page 8.

TIP GUARD

ALWAYS 

have the tip guard in place on the spray gun 

while spraying. The tip guard alerts you to the injection 

hazard and helps prevent accidentally placing your fingers 

or any part of your body close to the spray tip.

USE EXTREME CAUTION

 when cleaning or changing 

spray tips. If the spray tip clogs while spraying, engage the 

gun safety latch immediately. 

ALWAYS 

follow the 

PRESSURE RELIEF PROCEDURE

 

before removing  the spray tip to clean it. 

NEVER 

wipe off build up around the spray tip.

ALWAYS 

remove tip & tip guard to clean 

AFTER 

pump 

is turned off and the pressure is relieved by following the 

PRESSURE RELIEF PROCEDURE.

INJECTION HAZARD

ALWAYS INSPECT SPRAYING AREA

WARNINGS CONTINUED ON NEXT PAGE.........

WARNINGS

MEDICAL ALERT - Airless Spray Wounds
If any fluid appears to penetrate your skin, get EMERGENCY 

MEDICAL CARE AT ONCE. DO NOT TREAT AS A SIMPLE 

CUT. Tell the doctor exactly what fluid was injected.  Have 

him read the following "NOTE TO PHYSICIAN".

GENERAL PRECAUTION

MEDICAL TREATMENT      

SPRAY TIP SAFETY

TIP GUARD

SPRAY GUN SAFETY

Содержание EZ Rent 570

Страница 1: ...001 794 Sept 08 AIRLESSCO EZ Rent 570 700 AIRLESS PAINT SPRAYER SERVICE OPERATION MANUAL...

Страница 2: ...ssembly Calibration 23 Electrical System 24 Pressure Control Box 25 Replacement of Electrical Components 26 Troubleshooting Machine Does Not Start 27 EZ Series Quick Reference Guide 28 Notes 29 Airles...

Страница 3: ...TED TO THE USAGE OF THIS EQUIPMENT ON PAGES 2 3 4 READ LEARN AND FOLLOW THE PRESSURE RELIEF PROCEDURE ON PAGE 8 OF THIS MANUAL EZ Rent 570 EZ Rent 700 Max Pressure 3000 PSI 3000 PSI Output FreeFlow 0...

Страница 4: ...nquishing equipment is readily available and properly maintained NEVER LEAVE SPRAYER UNATTENDED WITH PRESSURE IN THE SYSTEM FOLLOW PRESSURE RELIEF PROCEDURES ON PAGE 8 Keep spraying area free from obs...

Страница 5: ...the risk of static sparking fire or explosion which can result in serious bodily injury and property damage ALWAYS GROUND ALL OF THESE COMPONENTS 1 Sprayer Connect a ground wire and clamp supplied to...

Страница 6: ...without the tip in a well ventilated area into the grounded steel bucket 4 Never use high pressure in the cleaning process USE MINIMUM PRESSURE 5 Do not smoke in spraying cleaning area Reduce the risk...

Страница 7: ...th your gun on its safety features and how to engage safety latch 2 Pour enough clean compatible solvent into a large empty metal pail to fill the pump and hoses 3 Place the suction tube into the pail...

Страница 8: ...nd counterclockwise CCW to decrease pressure 1 LEARN THE FUNCTIONS OF THE CONTROLS FIG 6 PRESSURE CONTROL KNOB used to adjust pressure only Turn clockwise to increase pressure and counterclockwise to...

Страница 9: ...are spraying is water based or if it could harden in the sprayer overnight See Flushing Use a compatible solvent to flush then fill the pump and hoses with an oil based solvent such as mineral spirit...

Страница 10: ...E IS ONLY A VERY SLIGHT GAP NOTE THE VALVE HANDLE CAN MOVE BOTH CLOCKWISE AND COUNTER CLOCKWISE AND CAN FACE DIFFERENT DIRECTIONS If the SPRAY TIP OR HOSE IS CLOGGED follow Step 1 through 5 above Expe...

Страница 11: ...afety latch return handle to the spray position Spray Position Shown REVERSE TO UNPLUG RETAINING NUT CLOGGED FLAT TIP Should the spray tip become clogged relieve pressure from hose by following the PR...

Страница 12: ...Adapter 5 120 562 Trigger Guard 6 120 539 Pivot Trigger Pin 7 120 509 Gun Head 8 120 540 Actuator Pin 2 9 120 536 Gun Plate 10 120 038 Nut 11 120 056 Plastic Washer 12 120 538 Gun Trigger Lock 13 120...

Страница 13: ...d Orifice clogged Tip damaged Clean carefully Replace with new tip Craters or pock marks bubbles on work Solvent balance Use 1 to 3 short solvents remainder long solvents this is most likely to happen...

Страница 14: ...517 519 521 523 525 527 531 535 12 14 305 356 613 615 617 619 621 623 625 627 631 635 639 641 14 16 356 406 715 717 721 739 741 754 16 18 406 457 815 819 821 831 20 24 508 610 NEW WIDE TIPS W21 W23 W...

Страница 15: ...emove the cover over the motor if applicable 3 Open the two covers at the rear of the motor 4 Disconnect the brush wire 5 Pull out the wire 6 Push the brush retainer clip in and withdraw 7 Remove the...

Страница 16: ...ace gun filter inlet filter and or manifold filter service outlet valve clean or replace prime valve 100 180 tighten packing nut repack unit Unit does not maintain good spraying pressure Blown spray t...

Страница 17: ...Push the two bolts through the tube spacers screw them into the cover assembly Using a 1 2 wrench tighten the two bolts evenly alternating between them until you reach 20 ft lbs 4 Reassemble lower su...

Страница 18: ...king Removal Tool 331 465 Piston Holder 331 195 3 8 dowel 331 196 SERVICING THE INLET VALVE 1 Un thread and remove suction nut from the fluid pump body 2 Remove suction seat O ring suction ball and su...

Страница 19: ...il for 10 minutes prior to reassembly REASSEMBLY FIG 17 PARTS LIST ON FOLLOWING PAGE 1 2 3 4 5 6 7 8 9 10 13 14 15 16 17 18 19 20 21 2 1 22 23 REFER TO FIGURE 17 1 Take lower male gland place it down...

Страница 20: ...Seat Hi Boy 9 331 034 Suction Nut 10 331 314 Outlet Seat Retainer 11 331 026 Outlet Seat 12 331 100 O Ring 13 331 027 Outlet Ball PARTS LIST FIGURE 17 18 CONT Item No Part No Description 14 331 708 Pi...

Страница 21: ...2 PARTS LIST FIGURE 20 Item No Part No Description 1 331 061 Sleeve Bearing 2 331 103 Washer 2 3 331 197 Screw 2 SERVICING GEAR BOX ASSEMBLY GEARBOX SLEEVE BEARING REPLACEMENT PARTS LIST FIGURE 19 Ite...

Страница 22: ...t 2 6 331 477 Cup Support 7 331 476 Cup Assembly 8 143 029 Collar 2 9 113 019 10 Wheel 2 PARTS LIST FIGURE 21 CONT Item No Part No Description 10 305 039 Spacer 2 11 331 337 Rubber Edge 2 12 117 044 K...

Страница 23: ...bber Edge 4 117 044 Knob 5 331 323 Terminal Box 6 111 037 Heatsink Screws PARTS LIST FIGURE 22 CONT Item No Part No Description 7 143 029 Collar 2 8 113 019 10 Wheel 2 9 113 030 Spacer 2 10 331 048 Ru...

Страница 24: ...ose Assy 7 331 425 Bypass Hose 8 331 090R Fitting 9 111 016 Nylon Tie 10 331 135 Spring Clip 5 4 3 8 2 6 1 7 9 10 FIG 23 LO BOY AND CARRY CHASSIS 331 238 HI BOY CHASSIS 331 284 PARTS LIST FIGURE 24 It...

Страница 25: ...et of Coro chek and water 4 Turn prime pressure relief valve to the prime open position 5 Turn pressure control knob clockwise until machine starts to prime 6 Place the prime pressure relief valve in...

Страница 26: ...331 99 Pressure Control Assy 110V 9 117 207 Jumper 10 331 294 99 Sensor 11 331 297 Potentiometer 12 301 002 Nut 13 117 044 Knob 14 331 377 LCD Display PSI 15 115 068 O Ring 16 117 452 Ground Wire FIG...

Страница 27: ...68 O Ring 4 117 044 Knob 5 100 109 Nipple 6 331 297 Potentiometer 7 111 037 Screw PARTS LIST FIGURE 26 CONT Item No Part No Description 8 120 021 Nut 9 100 029 Plated Plug 10 331 161 Strain Relief 1 2...

Страница 28: ...n reverse order 1 Lower the pressure control assembly as described above 2 Disconnect the two wires on the toggle switch 3 Use a 9 16 wrench to loosen the nut on the toggle switch shaft 4 Reassemble i...

Страница 29: ...d to step six Pressure Control Assembly Board STEP 6 If everything checks out in steps one through five and the power indicating light is still out replace the pressure control assembly Motor STEP 7 R...

Страница 30: ...slight gap between handle body When the relief valve is closed the system is pressurized Handle as a loaded firearm ON OFF Toggle Switch Turns the unit ON and OFF OPERATION Always use low pressure in...

Страница 31: ...29 NOTES...

Страница 32: ...Gallon strainer HOSE COVER 4 mil poly protects your airless hose from paint and abrasion damage Comes in 1000 roll with perforations each 50 100 219 Hose Cover Roll 100 426 Case of 6 Rolls For a compl...