Operation
10
3A1184A
Shutdown
1.
Relieve Pressure
, page 7.
2.
Clean the tip and gun as recommended in the sepa-
rate Gun Manual supplied with the gun.
3.
If spraying water-based material or a material that
could harden in the sprayer overnight, flush the
sprayer after use. See
Flushing
, page 8.
Storage
Short Term
1.
Flush sprayer with compatible solvent before stor-
ing, then fill the pump and hoses with an oil based
solvent such as mineral spirits or Graco or Airlessco
Pump Armor.
•
For oil base paint: flush with mineral spirits
•
For water-base paint: flush with water, then min-
eral spirits and leave the pump, hose and gun
filled with mineral spirits.
Long Term
For longer storage, use Graco or Airlessco Pump Armor.
Shut off sprayer,
Relieve Pressure
, page 7, and make
sure prime valve is left open.
Start Up After Storage
Before using water-base paint, flush sprayer with soapy
water and then a clean water flush. When using oil-base
paint, flush out the mineral spirits with the material to be
sprayed.
NOTE:
Always store unit indoors.
Содержание 24F572