![airleben airLeakProofTester Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/airleben/airleakprooftester/airleakprooftester_user-manual_2877312019.webp)
19
User manual
|
airLPT113
Version v1.0
|
Status 24.11.2016
LEAK DETECTION MODE
In the TEST PRESSURE submenu
you can set the test pressure between the limits 10 to 500 Pa in 10 Pa steps by
using the arrow keys and (the pressure setting is 200 Pa when you call
up this mode for the first time). If you hold down the arrow keys for more than
1.5 seconds, the pressure value is changed quickly.
F2 – CHANGE
Change the “pressure” parameter“
In the submenu DURATION you can set a test time
from between 1 to 30 min in 1 min steps by using the arrow keys and (the
time setting is 15 min when you call up this mode for the first time). If you hold
down the arrow keys for more than 1.5 seconds, the time value is changed
quickly.
F2 – CHANGE Change the “time” parameter
The Leak Search Mode Testing starts after the START key (F3) has been pres-
sed. The current pressure in Pa and the remaining time is displayed continuous-
ly. The device switches off the fan when the time has expired. You can also
terminate this mode prematurely by pressing the STOP key (F3).