INSTALLATION INSTRUCTIONS

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1. 

Unpack fan from the carton and confirm that all pieces are present. In addition to the 

exhaust fan you should have:

 

 

1 - Duct Adapter Panel

 

 

1 - Side Panel (attached)

 

 

1 - Damper Assembly (attached)

 

 

2 - Mounting Brackets

 

 

1 - Hardware bag

 

 

          7 - Screws

 

 

          4 - Nuts

 

 

1 - Instruction/Safety Sheet   

2. 

Choose the location for your fan. To ensure the best air and sound performance, it is 

recommended that the length of ducting and the number of elbows be kept to a minimum, 

the radius of each elbow be as large as possible for the installation, and that insulated 

hard ducting be used. This fan will require at least 12" of clearance in the ceiling or wall, 

and will mount through drywall up to ½" thick. The fan mounts between 24" on center 

joists using the provided mounting brackets.

3. 

No additional vibration deadening materials are needed for this fan.

SECTION 2

Determine Discharge

1. 

Determine if you will require the unit to exhaust vertically/horizontally or at a right angle 

and install the included duct adapter panel accordingly, using the included screws 

(Figure 1).

NOTE:

 In the right angle configuration the air will enter the unit and flow out the side at a 90° 

angle. In the horizontal/vertical discharge configuration, the air will enter the unit and flow 

directly out the other side.

2. 

Once the duct adapter panel is installed, using the same procedure as in Step 1, install 

the side panel onto the open end of the housing (this will be dependent on how you 

have chosen to exhaust the unit).

SECTION 3

Mounting to a Joist

1. 

If the mounting brackets are not already in place, install both brackets through the top 

set of slots on the fan housing and secure in place with the four included nuts as shown. 

Center the fan housing between the joists and secure the mounting brackets with screws 

(not included) to the joist. Adjust the height of the housing so that it will be flush with the 

finished ceiling by loosening the mounting bracket nuts and sliding the housing up or 

down on the bracket. Full tighten all four nuts to secure the housing in place 

(Figure 2).

www.airkinglimited.com

6727926 Rev. C 6-18

2 of 8

SECTION 4

Hanging Installation

1. 

If the mounting brackets are not already in place, install both brackets through the top 

set of slots on the fan housing and secure in place with the four included nuts as shown. 

Lift unit up onto the threaded rods and secure in place using appropriate hardware (not 

included) 

(Figure 3).

SECTION 5

Ducting

CAUTION:

 

ALL DUCTING MUST COMPLY WITH LOCAL AND 

NATIONAL BUILDING CODES.

NOTE:

 To ensure quiet operation, at least 8 feet of insulated flexible duct or insulated duct board 

needs to be installed between the exhaust or supply grille(s) and the fan.

1. 

Before installing the ducting, make sure the fan’s 2 pin and 3 pin quick connect motor 

cords are plugged into the corresponding receptacle located on the interior wire 

compartment cover. These cords will only fit one way into the receptacles 

(Figure 4)

.

2. 

Connect the ducting to the fan’s duct collar 

(Figure 5).

 Seal ducting to housing with 

appropriately rated tape. Use screws (rectangular duct) or suitable clamps (round duct) 

to secure in place. Do not allow screws to interfere with operation of damper. Always 

duct the fan to the outside through a wall or roof cap. It is recommended that low 

restriction termination fittings be used.

SECTION 6

Wiring

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE 

MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR 

NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING 

ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE:

 This unit includes a side access panel for wiring that does not require the removal of the 

fan’s blower assembly.
1. 

Remove the wire compartment cover screw and place cover in a secure place 

(Figure 6).

Figure 2

Bracket

Housing

Nut

Joist

Figure 3

Bracket

Housing

Nut

Threaded Rod

Figure 5

Housing

Ducting

Duct Collar

Right Angle 

Discharge

Horizontal/

Vertical 

Discharge

Figure 1

Duct 

Adapter

Screws

Figure 4

Содержание AKZA200D

Страница 1: ...dance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equi...

Страница 2: ...with the finished ceiling by loosening the mounting bracket nuts and sliding the housing up or down on the bracket Full tighten all four nuts to secure the housing in place Figure 2 www airkinglimited...

Страница 3: ...an once installed To access the interior unscrew the screws holding the panel in place Figure 9 2 Reinstall the access panel by making sure the tabs are inserted into the slots on the housing and pivo...

Страница 4: ...ED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRA...

Страница 5: ...dies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Sui...

Страница 6: ...bo tier de sorte qu il soit en affleurement avec le plafond fini en desserrant les crous du support de montage et le bo tier coulissant vers le haut ou vers le bas sur le support Serrez compl tement l...

Страница 7: ...er soigneusement les fils l int rieur du compartiment pour le raccordement et replacer le couvercle du compartiment en le fixant avec la vis qui fut enlev e pr c demment SECTION 7 Compl tion de l inst...

Страница 8: ...CTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU R CEPTACLES DE MAISON MALGR N IMPORTE QUOI L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILIT D AIR...

Отзывы: