AirKing AKZA200D Скачать руководство пользователя страница 1

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

SAVE THESE INSTRUCTIONS

www.airkinglimited.com

6727926 Rev. C 6-18

1 of 8

Exhaust Fan

AKZA200D, AKZA200D1

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN 

THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL 

INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock and 

injury to person, including the following:

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer. If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA) and the American Society for Heating, 

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. 

DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE 

MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.
e)  This unit must be grounded.
f)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

g)  Read all instructions before installing or using exhaust fan.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, DO NOT USE THIS FAN WITH 

ANY SOLID-STATE SPEED CONTROL DEVICE.

WARNING:

 DO NOT USE IN KITCHENS.

WARNING: 

THE DUCTING FROM THIS FAN TO THE 

OUTSIDE OF THE BUILDING HAS A STRONG EFFECT 

ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE 

THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR 

BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH 

SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND 

THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD 

GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT 

ACHIEVE THEIR RATED AIRFLOW.

Содержание AKZA200D

Страница 1: ...dance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equi...

Страница 2: ...with the finished ceiling by loosening the mounting bracket nuts and sliding the housing up or down on the bracket Full tighten all four nuts to secure the housing in place Figure 2 www airkinglimited...

Страница 3: ...an once installed To access the interior unscrew the screws holding the panel in place Figure 9 2 Reinstall the access panel by making sure the tabs are inserted into the slots on the housing and pivo...

Страница 4: ...ED WARRANTY INCLUDE I INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER OR II REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRA...

Страница 5: ...dies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Sui...

Страница 6: ...bo tier de sorte qu il soit en affleurement avec le plafond fini en desserrant les crous du support de montage et le bo tier coulissant vers le haut ou vers le bas sur le support Serrez compl tement l...

Страница 7: ...er soigneusement les fils l int rieur du compartiment pour le raccordement et replacer le couvercle du compartiment en le fixant avec la vis qui fut enlev e pr c demment SECTION 7 Compl tion de l inst...

Страница 8: ...CTS DE N IMPORTE QUELLE CAUSE OU II LE REPLACEMENT OU LA R PARATION DE TOUS FUSIBLES DISJONCTEURS OU R CEPTACLES DE MAISON MALGR N IMPORTE QUOI L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILIT D AIR...

Отзывы: