INSTALLATION INSTRUCTIONS

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1. 

Unpack fan from the carton and confirm that all pieces are present. In addition to the 

exhaust fan you should have:

 

 

1 - Grill

 

 

1 - Damper Assembly (attached)

 

 

2 - Mounting Brackets (attached)

 

 

1 - Instruction/Safety Sheet   

2. 

Choose the location for your fan. To ensure the best air and sound performance, it is 

recommended that the length of ducting and the number of elbows be kept to a minimum, 

the radius of each elbow be as large as possible for the installation, and that insulated 

hard ducting be used. This fan will require at least 12" of clearance in the ceiling or wall, 

and will mount through drywall up to ½" thick. The fan mounts between 24" on center 

joists using the provided mounting brackets.

3. 

No additional vibration deadening materials are needed for this fan.

SECTION 2

Mounting to a Joist

1. 

If the mounting brackets are not already in place, install both brackets through the top 

set of slots on the fan housing and secure in place with the four included nuts as shown. 

Center the fan housing between the joists and secure the mounting brackets with screws 

(not included) to the joist. Adjust the height of the housing so that it will be flush with the 

finished ceiling by loosening the mounting bracket nuts and sliding the housing up or 

down on the bracket. Full tighten all four nuts to secure the housing in place 

(Figure 1).

SECTION 3

Existing Construction

1. 

Install two - 2 x 4 headers (not included) between the joists 

(Figure 2)

. Install the 

mounting brackets through the top set of slots on the fan housing and secure in place 

with the four included nuts. Position the fan housing between the headers and secure 

the mounting brackets with screws (not included) to the header. Adjust the height of the 

housing so that it is flush with the finished ceiling by loosening the mounting bracket 

nuts and sliding the housing up or down on the bracket. Fully tighten all four nuts to 

secure the housing in place 

(Figure 3)

.

www.airkinglimited.com

6728070 Rev. F 6-18

2 of 8

SECTION 4

Hanging Installation

1. 

If the mounting brackets are not already in place, install both brackets through the top 

set of slots on the fan housing and secure in place with the four included nuts as shown. 

Lift unit up onto the threaded rods and secure in place using appropriate hardware (not 

included) 

(Figure 4).

SECTION 5

Converting discharge

1. 

To convert unit from right angle discharge to horizontal/vertical discharge, remove 

screws holding the side access panel and duct adapter panel in place. Switch the 

side access panel location with the duct adapter panel 

(Figure 5). 

In the right angle 

configuration the air will enter the unit and flow out the side at a 90° angle. In the 

horizontal/vertical discharge configuration, the air will enter the unit and flow directly 

out the other side.

SECTION 6

Ducting

CAUTION:

 

ALL DUCTING MUST COMPLY WITH LOCAL AND 

NATIONAL BUILDING CODES.

1. 

Connect the ducting to the fan’s duct collar 

(Figure 6).

 Seal ducting to housing with 

appropriately rated tape. Use screws or suitable clamps to secure in place. Do not allow 

screws to interfere with operation of damper. Always duct the fan to the outside through 

a wall or roof cap. It is recommended that low restriction termination fittings be used.

SECTION 7

Wiring

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE 

MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR 

NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING 

ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
NOTE:

 This unit includes a side access panel for wiring that does not require the removal of the 

fan’s blower assembly.
1. 

Remove the wire compartment cover screw and place cover in a secure place 

(Figure 7).

Figure 2

Joist

2 x 4 Header

2 x 4 Header

Joist

Ceiling

Right Angle 

Discharge

Figure 5

Horizontal/Vertical 

Discharge

Figure 1

Bracket

Housing

Nut

Joist

Figure 4

Bracket

Housing

Nut

Threaded Rod

Figure 6

Housing

Ducting

Duct Collar

Bracket

Header

Figure 3

Содержание AKA130

Страница 1: ...ccordance with all applicable codes and standards including fire related construction b Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning...

Страница 2: ...down on the bracket Fully tighten all four nuts to secure the housing in place Figure 3 www airkinglimited com 6728070 Rev F 6 18 2 of 8 SECTION 4 Hanging Installation 1 If the mounting brackets are n...

Страница 3: ...nnect the harness from the capacitor at the quick connect fitting and remove the Boost Label from the quick connect fitting on the boost capacitor 3 Plug the motor harness into the boost capacitor SEC...

Страница 4: ...REPLACMENT OR REPAIR OF ANY HOUSE FUSES CIRCUIT BREAKERS OR RECEPTACLES NOTWITHSTANDING ANYTHING TO THE CONTRARY IN NO EVENT SHALL AIR KING S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED TH...

Страница 5: ...incendies b De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulemen...

Страница 6: ...le haut ou vers le bas sur le support Serrez compl tement les quatre crous pour fixer le bo tier en place Figure 3 www airkinglimited com 6728070 Rev F 6 18 6 of 8 SECTION 4 Installation suspendue 1...

Страница 7: ...connect fitting on the boost capacitor 3 Branchez le harnais du moteur dans le condensateur d amplification SECTION 10 Utilisation et entretien ATTENTION VOUS ASSURER QUE L ALIMENTATION EST COUP E AU...

Страница 8: ...CLES DE MAISON MALGR N IMPORTE QUOI L EFFET CONTRAIRE DANS AUCUN CAS LA RESPONSABILIT D AIR KING SOUS UNE GARANTIE EXPRESSE OU TACITE NE D PASSERA LE PRIX D ACHAT DU PRODUIT ET UNE TELLE RESPONSABILIT...

Отзывы: