READ ALL OF THESE INSTRUCTIONS CAREFULLY AND FOLLOW THEM EXACTLY !
These instructions are for model 6S and 8S chimneys used for 1,000° F for continuous burn and up to
1,400° F for periods up to one hour and 2,100° F for periods up to 10 minutes.
This chimney is suitable for use with appliances burning gas, oil, coal (
NOTE:
Certain types of coal
have a high sulfur content, which causes corrosion of stainless steel. Therefore this type of coal is not
recommended for use with factory built chimneys.) or wood such as cooking ranges, heating or fire-
place stoves, central furnaces, floor furnaces, hot water and steam heating boilers, recessed or unit
heaters, water heaters, domestic type incinerators, bakery ovens, and for industrial type low heat
appliances (NFPA - Table 9 - IP). (These chimneys shall be installed in accordance with local building
codes or as recommended by NFPA No. 211 and 54.) Chimneys installed without the use of the starter
section (6SS, 8SS) are listed to UL 103 (1,700° only), and may be connected to residential and building
heating appliances which are gas or oil fired ONLY, as specified in Note 3 to Table 1-2(a) of NFPA 211.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTIONS IN YOUR AREA
.
The chimneys can be installed in single or multi-story buildings with maximum permissible overall
height from support to top of housing of 50’.
A minimum clearance of 2 inches of air space to combustible materials
, building insulation,
enclosure walls, and roof must be maintained. Do not place any insulation material in clearance spaces
around pipe. Clearances at floor joists, and ceilings are established by the installation of the factory
furnished base supports and firestop shields and may be less than 2”. The flue gas exits must be a
minimum of 3’ above the roof and not less than 2’ above any projection within 10’.
A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS
FAILURE TO MAINTAIN REQUIRED CLEARANCE (AIR
SPACES) TO COMBUSTIBLE MATERIALS, IT IS OF THE
UTMOST IMPORTANCE THAT THIS CHIMNEY BE
INSTALLED ONLY IN ACCORDANCE WITH THESE
INSTRUCTIONS.
CKS
OTK
RSK
HL
Ceiling and Roof
Through-the Wall
“A” Frame
Decorative Housing
Order: CHASE KIT
& HTK KIT
Order: OUTSIDE
WALL KIT
Order: ROOF
SUPPORT KIT
Order: CHIMNEY
HOUSING KIT & HTK
KIT
18” Stainless Steel
Telescoping Section
Boot Flashing
Top Cap
4 Panels
Attic Insulation
Shield (Contained in
HTK Kit)
Starter Section
(Contained in
HTK Kit)
Roof Support
Starter Section
Boot Flashing (High pitch
available on order)
Storm Collar
Round
Termination
Cap
Round
Termination
Cap
3 Wall Bands
Weather Shield
Adjustable Snout Tee
Tee Support
Face Plate
Matte Black
Adjustable Wall
Thimble Matte Black
Round
Termination
Cap
Storm Collar
Boot Flashing
0/12 to 6/12
Pitch
Starter Section
(Contained in HTK
Kit)
Ceiling Cover Base
Support Matte Black
Attic Insulation
Shield (Contained
in HTK Kit)
Ceiling Cover Base
Support Matte
Black
At least 2 ft
When
10ft or
Less
Minimum
3 ft