13
Reading temperature sensors
4 ZONE
Both Main & Display units are equipped with room temperature sensors.
In Cool mode, the reading temperature is from Main unit‟s sensor or Display unit‟s sensor can be selected by
Jumper at connector P21.
In Heat mode, the reading temperature is from Display unit‟s sensor.
If two Display units are installed the reading temperature will be either
a) The average value of two readings, or
b) From the last Display unit which the button is pressed
This option can be selected by Jumper OP4 on Main unit.
Offset temperature
In heat mode, the offset for room temperature can be set for 0 or 1
o
C
Error display
When there is any error, the LED on Display unit will blink and the LCD shows error status.
Error code
Description
LED Power blinking
Er : 03
Compressor overload protection
Yes
Er : 04
Anti overheat protection
Yes
Er : 05
Room sensor error
Yes
Er : 06
De-ice sensor error
Yes
Er : 07
Freeze sensor error
Yes
Er : 08
Protection & Alarm Damper
Yes