4
2.2
Motor protection
The QT150 HT has an energy-saving maintenance-free EC Motor with high
efficiency. The motor is equipped with a thermal contact, wired in series, which
automatically switches on/off after cooling. If the motor is blocked there will be an
attempt to restart it every 3 seconds.
2.3
Start-up performance
To start the motor a certain rotor position is required. If it doesn’t detect it, it outputs
pulses to the rotor in order to reach this position. This may take a few seconds. After
switching off the fan, switch-on inhibit activates the fan for 15 sec. to protect the
motor from rapid on/off switching.
CHAPTER 3
SPECIFICATIONS/
DIMENSIONS
M1/150 F
3.0
Specifications
Impeller – Ø
137
Electrical supply
NYM-0 4x1,5 mm
2
Alternating current
1 ̴
Degree of protection IP 45
(jet-proof)
Voltage/frequency
230 V, 50Hz
Protection class
II
Power input (W)
9 / 6
Weight approx. kg
1.2
Rated current (mA)
80 / 60
Rotational speed
1900/1600
Flow volume (m
3
/h)
260 / 220
Shut down (min.)
6,12,18,24
(adjustable)
3.1
Product lifetime
This unit is designed for a product life of at least 40.000 hours in Speed 1 mode with
maximum power in the maximum permissible ambient temperature.
3.2
Accessories
9041315 2
Speed Switch
Order Nr.
3.3
Dimensions
Содержание QT 150HT