background image

Operating Instructions PT-LE

4

1.

Safety Instructions

1.1.

Use for Intended Purpose Only

The PT-LE differential pressure transducer registers both differential pressure and 
positive/negative gauge pressure.

The operational requirements on the rating plate and in the "Specifications" chapter -
and the safe supply voltage in particular - must be kept to.

The transducer is only to be handled in conformity with these operating instructions. 
No modifications to the transducer are permitted. The manufacturer is not liable for 
damage arising from any incorrect use or one at variance to the intended purpose. 
Claims to warranty in such an instance would be forfeited.

1.2.

Transport, Installation, Connection and Startup

Do not block the pressure inlets on the transducer being moved! Changes in 
barometric pressure may damage transducers with low measuring ranges.

Only qualified personnel are to assemble the appliance and see to its electrical 
connections. They must be instructed as such and be assigned by the plant operator.

Only instructed persons as assigned by the plant operator are to operate the 
transducer.

Do not perform any functional test involving compressed or breathable air. This 
would otherwise damage those transducers with low measuring ranges.

Measurement errors may occur should the appliance not be protected from sunlight.

Specific safety instructions are given in the individual chapters.

1.3.

Malfunctions, Maintenance, Repairs, Disposal

Malfunctions which cannot be put right as specified in Chapter 8 and damage at the 
appliance itself must be immediately reported to the qualified personnel with 
responsibility for the electrical connections.

The appliance must be taken out of service by the qualified personnel responsible 
until the malfunction has been put right and also secured against being 
unintentionally used.

Always switch off the power to the appliance before it is opened!

The appliance does not need any maintenance.

Only the manufacturer is to carry out repairs.

The electrical components of the transducer contain both environmentally hazardous 
materials and materials that can be reused. That is why the appliance is to be 
recycled once it is finally immobilized. The environment directives on this from the 
country in question must be followed.

Содержание PT-LE

Страница 1: ...1 Differential Pressure Transducer PT LE Operating Instructions...

Страница 2: ...bols 5 2 Description oft he Transducer 6 3 Startup 6 3 1 Functional Description 6 3 2 Supply Voltage Connections in the Appliance 6 3 3 Connections for Two Wire System 7 4 Resetting Offset 7 5 Configu...

Страница 3: ...e entire service life of the transducer x They must be passed on to the succeeding personnel charged with operations x Any additions coming from the manufacturer must be inserted The manufacturer rese...

Страница 4: ...rsons as assigned by the plant operator are to operate the transducer Do not perform any functional test involving compressed or breathable air This would otherwise damage those transducers with low m...

Страница 5: ...dling the equipment WARNING It points to a hazard possibly extending from injures through to death should the instructions not be followed CAUTION It points to a hazard which could cause considerable...

Страница 6: ...ically mounted on a wall not subject to any vibrations To stop any condensed water entering the measurement cell the transducer together with the hose connections for positive gauge pressure and negat...

Страница 7: ...4 3 2 1 5 4 3 2 1 4 Resetting Offset After starting the pressure transducer give it some 15 minutes to warm up During this time the output signal may be unstable Zero point calibration of the applianc...

Страница 8: ...teaching of 4 measuring ranges into the appliance has been undertaken by the manufacturer The switches 1 and 2 of SW can be used to select the measuring range in question before the transducer is swi...

Страница 9: ...s output so that any adjusted time delay will also cause a delay in relay triggering 9 In case of Malfunctions Fault descritpion Possible cause Corrective action No output signal Supply voltage is not...

Страница 10: ...k Ohm 0 4 20 mA RL 500 Ohm 4 20 mA two wire 17 32 V RL 500 Ohm Switching contact optional max 230 VAC 6 A min 500 mW Display optional 3 digit LCD Overload range from 2 5 kPa 50 kPa 2 5 kPa 10 kPa 140...

Страница 11: ...Operating Instructions PT LE 11 11 Dimensional Drawing no LCD with LCD...

Страница 12: ...er and supplier in a wide variety of industries Originating from the Netherlands Observator has grown into an internationally oriented company with a worldwide distribution network and offices in Aust...

Отзывы: