Remove termination cover, see Fig. A. (Screws
marked with 1, 2, 3.)
Fig. A
5.
Cable (3 core flex) to be placed as shown in
Fig. B. Electrician to make electrical connections
(3 core 1mm
2
flex, Ø7mm [17/64”] specified) as
shown in Fig. C. Stripped ends to be kept to a
minimum. Replace termination cover.
Fig. B
Using template, cut hole in glass ø230 ± 2mm.
Slide internal clamp over your arm as shown.
Fold external clamp and insert through the hole
in the window pane.
Make sure the seal of external clamp is against
the glass, then align and insert the bolts through
internal clamp. Brass nuts supplied should then
be connected to bolts and finger tightened only.
If required, apply liquid or similar soap to foam
seal on inside of external clamp. Carefully
slide cylindrical window grille outlet end of
fan assembly through opening. With screws
provided, attach fan assembly to window clamp
assembly (4 places).
1.
4.
2.
3.
Fan
assembly
Apply soap to
the foam seal
Internal
clamp
External
clamp
Finger
tighten
only
Screws
marked 1,
2, 3, retain
the terminal
cover to the
chassis.
Break tab for
cable access
7105A
Auto Switched
& 7107A
Pull-Cord Switched
MaxAir Window Exhaust Fan
Installation Instructions
© Clipsal Australia Pty Ltd