OPERATING INSTRUCTIONS

Operating instructions DUPLEXVENT DV145SE

For indoor air to stay healthy and benefi cial also for the structures 

of the dwelling, ventilation has to be in operation continuously. It is 

not advisable to stop ventilation even for longer holidays because 

it  makes  indoor  air  stuffy.  Also,  during  the  heating  season  indoor 

air humidity may condense in the ducts and structures and therefore 

cause humidity damage. The sensors automatically adjust ventilation 

to an optimal level even if the dwelling is empty.

Making the unit ready for operation

1.  Connect the plug to the mains supply. DUPLEXVENT DV145SE  

is now ready for operation.

2.  Start the unit and choose a suitable ventilation power at the 

control panel. There is either one or more control panels. See 

the operating instructions for control panel.

In normal conditions basic ventilation, with a change of air every 

two hours, is suffi cient in living areas. Boosting is needed during for 

example sauna baths, cooking, clothes washing or family parties. 

If  carbon  dioxide  and/or  humidity  sensors  have  been  installed  in 

the  system,  DUPLEXVENT DV145SE  automatically  takes  care  of 

demand-controlled ventilation.

Ventilation control

The unit can be controlled with a control panel. The standard week-

clock control can be used to control the fan power of the unit and 

the setpoint for supply air temperature.
Furthermore,  demand-controlled  ventilation  can  be  adjusted  with 

optional carbon dioxide and humidity sensors.
The  fan  power  of  the  unit  can  also  be  controlled  with  a  voltage 

signal.

Controlling ventilation with Airflow Digit SED 

control panel

The control panel can be used for the following 

ventilation control functions:

Functions for adjusting ventilation 
power

•  Starting and stopping.
•  Power adjustment (8 positions).
•  Setting the base fan speed and the 

maximum fan speed.

Ventilation  power  cannot  be  set  lower  than 

the base fan speed. When carbon dioxide and/or relative 

humidity  adjustments  are  activated,  power  cannot  be  adjusted 

higher than the maximum fan speed. When humidity and carbon 

dioxide  adjustments  have  been  switched  off,  fan  speed  can  be 

raised to speed 8. (See the operating instructions for control panel, 

Section 3.25.)

Ventilation control with carbon dioxide sensor 
(option)

•  In carbon dioxide control, DUPLEXVENT DV145SE adjusts fan speed 

so as to keep carbon dioxide content in the ventilation zone 

below the setpoint. When two or more sensors are used, fan 

speed is adjusted according to the highest measuring result.

•  1 to 2 carbon dioxide sensors can be connected as options to 

the DUPLEXVENT DV145SE unit.

•  The adjustment is switched on/off and, if needed, the setpoint 

(500...2000 ppm) is set at the control panel. The factory 

setting is 900 ppm. The recommended maximum carbon 

dioxide content in good indoor air is circa 1,000 ppm.

•  During control, the control panel can be used to raise fan 

speed to the maximum fan speed and to decrease it to the 

base fan speed. In carbon dioxide control, maximum fan 

speed limitation is enabled.

Controlling ventilation with humidity sensor (option)

There are two modes of adjusting fan speed: 
1  Automatic humidity setting, which is suitable for controlling 

humidity in for example washing rooms.

 

The program records current humidity level and selects it 

as the setpoint, which it then uses as the target for drying 

air in a bathroom, for instance after a shower. The setpoint 

automatically varies for instance according to season and is 

always at the right level. This setting is factory selected.

2  Humidity level can also be set fi xed. The setting can range 

between 1...99 %RH and is set at the control panel. This can 

be used in for example public saunas and swimming pools. The 

program aims at keeping humidity at the setpoint. The setpoint 

can be changed if needed. The mode of adjustment is chosen 

at the controller. Recommended humidity content of good indoor 

air is approximately 45%.

•  During this control, the control panel can be used to raise fan 

speed to the maximum fan speed and to decrease it to the base 

fan speed.

•  In humidity control, fan speed varies between the base and 

maximum fan speeds selected.

•  When the unit is fi rst taken into use with automatic setpoint 

search enabled (factory setting), it takes 3 to 10 hours for 

the program to defi ne the value. During this time, humidity 

adjustment is not enabled (because the fi rst value, selected at 

the factory, is 100%).

•  Automatic search is enabled even if humidity control is not 

selected.

Controlling ventilation with voltage signal

•  DUPLEXVENT DV145SE fan power can be controlled with a voltage 

signal coming from remote monitoring.

•  The signal can be used to select speeds 0 to 8. However, if 

carbon dioxide or humidity adjustment is enabled, the maximum 

fan speed cannot be exceeded. (See the operating instructions 

for control panel, Section 3.25.)

•  The signal changes the base fan speed.
•  The signal does not lock fan speed, i.e. fan speed can be 

changed at the control panel within the set limits. Carbon 

dioxide and humidity adjustment also operate within the set 

limits.

Carbon dioxide and humidity sensors

Voltage signal values 

Voltage values for each fan speed:
0  

0.20...1.25 VDC

1  

1.75...2.25 VDC

2  

2.75...3.25 VDC

3  

3.75...4.25 VDC

4  

4.75...5.25 VDC

5  

5.75...6.25 VDC

6  

6.75...7.25 VDC

7  

7.75...8.25 VDC

8  

8.75...10.00 VDC

DV145SE

Содержание DUPLEXVENT DV145SE

Страница 1: ...g maintenance and technical instructions Electrical connection 230 V 50 Hz 11 9 A plug Degree of protection provided by enclosures IP34 Fans Extract air 150 dm3 s 100 Pa direct current DC Supply air 140 dm3 s 100 Pa Heat recovery Cross counter flow heat recovery cell 80 Heat recovery bypass Automatic Electric post heating unit standard 900 W 3 9 A Additional heater 1500 W 6 5 A Fans Supply air G4 a...

Страница 2: ...ighest measuring result 1 to 2 carbon dioxide sensors can be connected as options to the DUPLEXVENT DV145SE unit The adjustment is switched on off and if needed the setpoint 500 2000 ppm is set at the control panel The factory setting is 900 ppm The recommended maximum carbon dioxide content in good indoor air is circa 1 000 ppm During control the control panel can be used to raise fan speed to th...

Страница 3: ...months The maintenance reminder symbol is acknowledged at the main display of the control panel See the operating instructions for control panel Section 3 1 The interval can be set between 1 and 15 months at the control panel Fireplace switch function booster Fireplace switch function See the operating instructions for control panel Section 3 12 The fireplace switch stops the extract air fan for 1...

Страница 4: ... can chan ge setpoints for the ventilation unit 2 3 Week clock control Week program on Week clock control can be switched on with the button and off with the button Week clock control is on when the week clock control symbol is in the main display In week clock control the base fan speed and supply air temperature of the unit are adjusted in accordance with the programme as described in Section 4 ...

Страница 5: ...electric radiator is selected with the and buttons depending on the type of post heating radiator the unit is equipped with Note Choosing the wrong type of post heating may cause a faulty post heating function 3 18 Choosing additional heater for unit Extraheater type Electric rad An electric or MLV radiator is chosen according to ventilation unit type with the and buttons This unit can be used onl...

Страница 6: ...ir fan can be decreased by decreasing the percentage Move the cursor with the arrow keys and change values with the and buttons Note that to exit and save when the programming is finished move the cursor below the word Exit and press or Changes in fan speed Sp and supply air temperature Temp are only made for the hours desired in other cases use N no change to previous Monday d 1 07 00 h 7 fan spe...

Страница 7: ...od operation of the ventilation unit and the best filtering result The replacement interval of filters depends on dust content in ambient air It is recommended to replace fans in spring and autumn but at least once a year MAINTENANCE INSTRUCTIONS Filters Heat recovery cell Heat recovery cell When you replace the filters you are also advised to check the cleanliness of the heat recovery HR cell D a...

Страница 8: ... and crank the plastic lock to the right using for instance a chisel figure 6 The fan then falls down and can be pulled out of the unit Disconnect the quick coupling of the fan conductors When needed detach the intermediate shaft of the bypass damper from the end of the partition wall figure 7 Condensing water During the heating season humidity of extract air condenses into condensing water Water ...

Страница 9: ...is displayed and the unit operates at speed 1 check the fan speed Wiring fault in the carbon dioxide sensor in the control panel or in the humidity sensor or the cable is of the wrong type Contact a maintenance company The connections have to be checked and corrected if necessary 9 Freezing alert message is displayed and the unit is stopped Antifreeze of the water circulating radiator is active NO...

Страница 10: ...ncy of the octave band Hz 63 41 50 56 58 59 64 67 69 35 45 49 51 51 56 58 58 125 45 53 56 59 62 65 68 71 33 43 46 49 49 54 56 59 250 50 54 57 61 63 66 68 70 24 32 37 40 40 45 47 49 500 48 53 56 59 60 63 65 68 37 43 46 48 48 52 54 56 1000 45 54 57 60 62 64 66 67 30 36 39 42 42 46 48 50 2000 35 46 50 55 58 61 64 66 22 32 34 38 38 43 45 48 4000 26 41 46 51 54 58 60 63 16 20 22 25 25 31 33 36 8000 21 ...

Страница 11: ... it must be replaced by the manufacturer authorised maintenance company or other qualified person in order to avoid danger T Supply air fan P Extract air fan M1 Protective voltage transformer 230 VAC 16 VAC L Earthed cord TK Safety switch R1 Additional heating radiator 90 C and 130 C with overheat protection R2 Post heating radiator 90 C and 130 C with overheat protection M Damper motor 24 V DC Wi...

Страница 12: ...e In this case remove one of the control panels and change the address of the other panel The above mentioned situation can arise in connection with the later installation of an additional control panel External electrical connection DUPLEXVENT DV145SE METAL M WHITE 2 B ORANGE 2 A WHITE 1 ORANGE 1 2 TWISTED PAIR 1 TWISTED PAIR NOTE Faulty connection of the wire DESTROYS CONTROL PANEL NOTE Faulty c...

Страница 13: ... Condensing water connections The delivery includes a water seal By connecting a pipe to the water seal the water condensing from extract air can be led to a floor drain not directly to the drain The pipe must not rise after the water seal The unit has to be mounted horizontally level so that condens ing water can get freely out of the unit The minimum distance between the top of the unit and the ...

Страница 14: ...What the units include can vary depending on the sales area MOUNTING Attic floor penetration plate option When an attic floor penetration plate is used the tightness of the vapour barrier has to be ensured Minimum distance to side walls is 15 mm 547 8 747 15 15 0 DV145SE ...

Страница 15: ...art Code 12 G4 coarse filter 978047 13 Bypass assembly indicate if 3475900 Right or left handed 14 Damper motor 930613 15 Extract air outlet 985035 16 Protective voltage transformer 940150 17 Motherboard 949045 18 Safety switch 948370 19 Additional heater 1500 W 942220 20 Post heater 900 W R 942211 Post heater 900 W L 942210 No Part Code 21 Door assembly 3476000 22 Door latch assembly 3355900 23 N...

Страница 16: ...mpliance with this requirement by an assessed and registered Competent Person should follow a Best Practice process and adopt air flow measurement Method A The Unconditional Method using a suitable UKAS certified measuring instrument Generically referred to as a Zero Pressure Air Flow Meter or Powered Flow Meter Further information on this method is detailed in NHBC Building Regulations Guidance N...

Отзывы: