This product requires the use of a forklift or other suitable lifting devices to be properly 
transported. Please do not attempt to lift the unit personally.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
To ship the unit, free access must be granted to the install location for a forklift, pallet truck 
or crane. It is delivered on its side and not upright, transportation in an upright position is not 
recommended. Do not attempt to lift it from the floor by hand. Ensure the forklift forks are 
long enough for the unit to be properly supported.  
 
 
 
 
 
 
 
 
 
 

Warning: 

Due to load the package must be transported by forklift, pallet 

truck or crane.  Ensure symmetrical load distribution and lift the device 
slowly. Always keep a close monitor on the package and do not stand 
underneath it. Do not attempt to operate this machinery and move the unit 
unless properly licensed.  
 

Warning: 

Risk of personal injury and equipment damage due to falling 

from the forklift! Before transporting the unit, please ensure the forks of the 
forklift truck are long enough to lift more than the entire underside of the 
unit! (See figure 2) refer to table 1.
 
 

 

Warning: 

Risk of personal injury and equipment damage due to an 

unpredictable center of gravity. If the package is fitted incorrectly, incorrect 
weight distribution means they can be dropped easily. Falling or overturned 
packages can cause damage or injury! Always check when moving the 
product and stay clear when in transit. 

 

Figure 2: Make sure the length of the forks is sufficient to reach the end of the package

 

Содержание 90001461

Страница 1: ...Installation operation and maintenance manual Part No 90001461 90001462 Purigo T1750 T2200 Please keep this manual with the product...

Страница 2: ...2 2 Electrical Connection 7 2 3 Recycling 7 3 0 Technical Information 7 4 0 Installation 10 4 1 Unboxing 10 4 2 Installation Location 10 4 3 Mobility 12 4 4 Electrical Connection 12 4 5 Levelling 12...

Страница 3: ...from small particles dust pollen bacteria and viruses Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footw...

Страница 4: ...pical residential commercial environment It is for indoor use only and works with 230V AC supply from a normal utility socket It can be used for filtering indoor air by means of recirculating it and r...

Страница 5: ...ation and box weight information is displayed below Table 1 Packaging Information Model Packed Quantity Box Dimensions LxWxH mm Weight Kg T1750 1 2360x810x780 240 T2200 1 2360x810x925 290 Warning When...

Страница 6: ...t the device slowly Always keep a close monitor on the package and do not stand underneath it Do not attempt to operate this machinery and move the unit unless properly licensed Warning Risk of person...

Страница 7: ...that came with the unit in a manner that is acceptable to the local authority It can be disposed as you would any other retail plug 2 3 Recycling Metal components of the product may be recycled always...

Страница 8: ...m dBa 57 60 Power Max W 494 473 Voltage V 230 230 Amps A 2 5 2 5 Frequency Hz 50 50 Height 2313 2332 Width 717 717 Depth 567 720 Weight Kg 150 180 Protection IP Rating 20 20 Body Construction Standing...

Страница 9: ...05 54 217 80 1305 1400 56 261 85 1400 1480 57 310 90 1480 1590 57 376 95 1590 1680 57 439 100 1680 1750 57 494 Table 5 T2200 Setting levels T2200 Adjustment levels Air Volumes m3 h Noise level at 1m d...

Страница 10: ...be kept clear for any reason such as a fire exit Allow easy access for adjustment of the potentiometer Do not place the unit inside a cupboard wardrobe or cabinet Do not rest heavy objects on the unit...

Страница 11: ...depend on the physical conditions of the installation space but to maintain good air circulation the distances listed below should be considered Table 6 Clearance for free airflow Model A mm B mm T17...

Страница 12: ...and cause noise To adjust the unit make sure it is first positioned in the correct place with the minimum clearances observed There are 2 nuts on each adjustable foot One is accessible from outside o...

Страница 13: ...the speed and the airflow Turn the potentiometer anti clockwise to decrease it The adjustment levels with power draw and airflow rates can be seen in section 3 0 Table 3 and 4 of this document Comfor...

Страница 14: ...Protective gloves serve to protect the hands against rubbing abrasions cuts or more injuries as well as contact with hot surfaces Protective footwear serves to protect against heavy falling parts and...

Страница 15: ...ing Check for corrosion contamination damage or scratches etc Clean and repair X Check for Damage Fix the damage X Air Filters Check for unacceptable levels of dirt odours and damage Replace the filte...

Страница 16: ...ges Filters are located as displayed on the unit and accessed through opening the door of the product using the key provided You will need to replace all filters at once Component No Description 0 Sup...

Страница 17: ...90001511 HEPA 14 610x610x292 90001512 Replacement filters must be ordered from Airflow Developments To replace the filters follow the step by step guidance below 1 Open the front door using the door...

Страница 18: ...lencer is clean and damage free from foreign objects Remove the dirt on each silencer using a vacuum cleaner and or a cleaning product without damaging the fabric covering the rock wool Danger after c...

Страница 19: ...w Developments Limited Aidelle House Lancaster House Cressex Business Park High Wycombe Buckinghamshire HP12 3QP UK Email info airflow com Telephone 44 0 1494 525252 Facsimile 44 0 1494 461073 Copyrig...

Отзывы: