Aircommand Sparrow Mk4 Скачать руководство пользователя страница 6

Sparrow Mk4 Installation Guide V5 

28

TH

 May 2015 

Page 6 of 16 

1. INSTALLATION POSITION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Fig 1: Sparrow Mk4 clearances required around roof top unit 

 

 

Before beginning, mark out the position of the unit 
considering the following important requirements: 
 

 

The  air  conditioner  should  be  situated  as 
centrally  as  possible  on  the  van,  to  ensure 
even air distribution. 

 

 

The  Sparrow  Mk4  may  be  oriented  in  any 
direction to the normal direction of travel. 

 

 

When  considering  the  installation  position 
remember  to  check  for  clearance  around  the 
plenum inside the van. 

 

 

Avoid  an  installation  position  where  a 
bulkhead,  cupboard  or  light  fitting  could 
interfere with the discharge air flow from the 
plenum. 

 

 

Avoid  an  installation  where  a  roof  joining 
seam  crosses  through  the  14”  square 
installation cut out

.  

 

It  is  important  that  the  unit  is  never 
more than 5° from the horizontal and the 
rear  of  the  unit  should  never  be  higher 

than the front when in use. 
 

Contact  Aircommand  if  your  installation  differs 
significantly. 
 
 
 
 
 

 

 
 
 
 
 

Fig 2: The footprint of the rooftop unit, and the plenum, measured from the hole. 

 

- The above outline on the left shows the minimum clearance required around the 
Sparrow Mk4 unit on the roof of the vehicle, distances shown are calculated from a 
14” square hole (360 x 360mm). 
 
-  The  above  outline  on  the  right  shows  the  minimum  clearance  required  around 
the 14” square hole (360 x 360mm) in order to accommodate the plenum.  

 
 

There should be a minimum of 
100mm clearance around the 
perimeter of the unit to allow for 
service access and air flow to 
condenser. 

Hot air is ejected from this 
exhaust; consider nearby 
roof hatch  

14” x 14” 
(360mm) 

SQUARE 

HOLE 

Содержание Sparrow Mk4

Страница 1: ...Sparrow Mk4 Installation Guide V5 28TH May 2015 Page 1 of 16 SPARROW MK4 OWNERS MANUAL INSTALLATION COMMISSIONING OF UNIT MAINTENANCE SPECIFICATIONS OPERATING INSTRUCTIONS SPARE PARTS WIRING DIAGRAM...

Страница 2: ...er der folgenden Adresse registriert werden www aircommand com au registration html GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifie...

Страница 3: ...FTOP AIRCONDITIONER Model Number 5860001 Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before installation The unit must be install...

Страница 4: ...nd all annexes Position the vehicle so that the annex will face the sun and protect the windows from direct radiation Turning off unneeded appliances that might increase the heat load inside the van C...

Страница 5: ...been properly read and understood Installation must confirm to nation wiring regulations and in particular AS3001 2008 DO NOT attempt to modify or add components to the installation procedure This eq...

Страница 6: ...roof joining seam crosses through the 14 square installation cut out It is important that the unit is never more than 5 from the horizontal and the rear of the unit should never be higher than the fr...

Страница 7: ...ted at the supply mains and or battery Failure to do so may result in personal injury or death TIP Always use crawl boards across the roof to avoid damage Fig 3 Shows an ideal roof structure with stro...

Страница 8: ...ant around bolt holes and then position unit over the weather collar and set down gently 5 CONNECT ELECTRICAL SUPPLY This unit MUST be installed in accordance with SAA Wiring regulations and in partic...

Страница 9: ...ler to provide longer bolts 7 ASSEMBLE DUCT Thread a hold down bar onto the M8 bolt and push the bolt almost all the way into the hole in each corner of the brace Fig 9 Leave a 10mm gap between the ho...

Страница 10: ...und the evaporator fan underneath the unit Then engage the four M8 bolts taking care to ensure the hold down bars slot into their recesses Fig 12 Highlights how the notch on the plastic duct slots ove...

Страница 11: ...screws to secure the cover s edges to the caravan ceiling Fig 16 In some instances a very small pilot hole may need to be drilled to guide the screws into place Replace the filters by sliding them int...

Страница 12: ...ealth risk particulalry to young children and the elderly Ensure that filters are cleaned in a safe and well ventilated area If a more thorough clean is required then the filters can be washed out usi...

Страница 13: ...h 555mm Weight 2 4kg AIRCOMMAND AUSTRALIA PTY LTD SPARROW MK4 MODEL NO 5860001 240V 50HZ REFRIGERANT 407C 450G RATED CAPACITY COOLING 2000W HEATING 2150W POWER INPUT COOLING 920 W HEATING 930 W RATED...

Страница 14: ...ure button is invalid in Fan only mode HEAT To heat press MODE button to highlight HEAT Select desired set point temperature by pressing TEMP buttons up or down It is recommended that AUTO fan speed b...

Страница 15: ...Sparrow Mk4 Installation Guide V5 28TH May 2015 Page 15 of 16...

Страница 16: ...Sparrow Mk4 Installation Guide V5 28TH May 2015 Page 16 of 16 Fuse 5x 20mm T5AL250V...

Отзывы: