OPERATING INSTRUCTIONS 

This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced  physical,  sensory  or 
mental  capabilities,  or  lack  of  experience  and  knowledge,  unless  they  have  been  given  supervision  or 

instruction concerning use of the appliance by a person responsible for their safety. 

Children should be supervised 

to ensure that they do not play with the appliance. 

OPERATION 

 

Turn the unit on by pressing the ON/OFF button once.  

 

Press the MODE button to cycle through options Cool, Dry, Heat and Fan. 

 

Turn the unit off by pressing the ON/OFF button once more. 

 
COOLING 

 

Cycle mode button to highlight COOL. 

 

You  may  select  High,  Med,  Low  or  Auto  fan  speeds  by  pressing  the  fan  button.  It  is  recommended  that  you 
choose Auto. 

 

Now select the desired room temperature (herein referred to as SETPOINT) by pressing the TEMP up or down 
keys, the readout will flash the set point temperature. Keep pressing the button until it flashes your desired set 
point. In approx. 5 seconds the display will resume reading the actual room temperature. The compressor will 
have a delayed start usually 3 minutes before unit starts to cool. 

Note

Any interruption to the power supply will cause the unit to delay compressor start up.

 

 

For simply recirculating air, choose the FAN mode. Choose any of the three fan speeds by pressing FAN. 

Note: Temperature button is invalid in Fan only mode.

 

  

HEAT 

 

To heat, press MODE button to highlight HEAT.  

 

Select desired set point temperature by pressing TEMP buttons up or down. It is recommended that AUTO fan 
speed by selected. 

 

After the delay, the compressor will start. Air will not flow until warm enough. This is to prevent cold draughts. 

 
DRY 

 

The DRY mode is used when the room temperature is close to comfortable but you wish to dehumidify. 

 

Press MODE button to highlight DRY. 

 

Set the temperature to desired set point. 

Note: the fan speed is locked in LOW

 

The compressor will cycle on and off at approximate intervals of 6 minutes to extract moisture from the air. 

 
SLEEP 

 

With the unit operating in cool mode, press SLEEP button to highlight the sleep light. The unit over the next hour 
will automatically raise the set point by 1 ˚C. Conversely in heat mode, the set point will be lowered 1˚C. 

 

The TIMER may be used to turn off the unit in the future (up to 24 hours) OR may be used to turn on the unit up 
to 24 hours in the future. 

 

Press TIMER button once and the display will flash. Within 3 seconds, press the timer button until you have set 
desired time (in hours) into the future to turn unit off. A subsequent press of the timer button will allow the time 
to start the unit to be programmed. 

 
LOCKING 

 

This provides a means of locking in the mode and fan settings. To lock, press TEMP DOWN key simultaneously 
with MODE button. Hold for 3 seconds and the lock indicator will light. To unlock, repeat above procedure. 

 

DISPLAY SETTING 

 

To change readout from ˚C to ˚F or vice versa: Press TEMP DOWN key simultaneously with the FAN key. 

 
 

 

Содержание Sparrow Mk4

Страница 1: ...Sparrow Mk4 Installation Guide V5 28TH May 2015 Page 1 of 16 SPARROW MK4 OWNERS MANUAL INSTALLATION COMMISSIONING OF UNIT MAINTENANCE SPECIFICATIONS OPERATING INSTRUCTIONS SPARE PARTS WIRING DIAGRAM...

Страница 2: ...er der folgenden Adresse registriert werden www aircommand com au registration html GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifie...

Страница 3: ...FTOP AIRCONDITIONER Model Number 5860001 Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before installation The unit must be install...

Страница 4: ...nd all annexes Position the vehicle so that the annex will face the sun and protect the windows from direct radiation Turning off unneeded appliances that might increase the heat load inside the van C...

Страница 5: ...been properly read and understood Installation must confirm to nation wiring regulations and in particular AS3001 2008 DO NOT attempt to modify or add components to the installation procedure This eq...

Страница 6: ...roof joining seam crosses through the 14 square installation cut out It is important that the unit is never more than 5 from the horizontal and the rear of the unit should never be higher than the fr...

Страница 7: ...ted at the supply mains and or battery Failure to do so may result in personal injury or death TIP Always use crawl boards across the roof to avoid damage Fig 3 Shows an ideal roof structure with stro...

Страница 8: ...ant around bolt holes and then position unit over the weather collar and set down gently 5 CONNECT ELECTRICAL SUPPLY This unit MUST be installed in accordance with SAA Wiring regulations and in partic...

Страница 9: ...ler to provide longer bolts 7 ASSEMBLE DUCT Thread a hold down bar onto the M8 bolt and push the bolt almost all the way into the hole in each corner of the brace Fig 9 Leave a 10mm gap between the ho...

Страница 10: ...und the evaporator fan underneath the unit Then engage the four M8 bolts taking care to ensure the hold down bars slot into their recesses Fig 12 Highlights how the notch on the plastic duct slots ove...

Страница 11: ...screws to secure the cover s edges to the caravan ceiling Fig 16 In some instances a very small pilot hole may need to be drilled to guide the screws into place Replace the filters by sliding them int...

Страница 12: ...ealth risk particulalry to young children and the elderly Ensure that filters are cleaned in a safe and well ventilated area If a more thorough clean is required then the filters can be washed out usi...

Страница 13: ...h 555mm Weight 2 4kg AIRCOMMAND AUSTRALIA PTY LTD SPARROW MK4 MODEL NO 5860001 240V 50HZ REFRIGERANT 407C 450G RATED CAPACITY COOLING 2000W HEATING 2150W POWER INPUT COOLING 920 W HEATING 930 W RATED...

Страница 14: ...ure button is invalid in Fan only mode HEAT To heat press MODE button to highlight HEAT Select desired set point temperature by pressing TEMP buttons up or down It is recommended that AUTO fan speed b...

Страница 15: ...Sparrow Mk4 Installation Guide V5 28TH May 2015 Page 15 of 16...

Страница 16: ...Sparrow Mk4 Installation Guide V5 28TH May 2015 Page 16 of 16 Fuse 5x 20mm T5AL250V...

Отзывы: