INSTALLATION PARTS LIST 

 
 
MAIN COMPONENTS 
 

1) CORMORANT MkII Rooftop 
Airconditioner  
 
2) Roof Seal Gasket 2 Pce 
 
3) Spigot 
 
4) Extension Duct 
 
5) Brace Assembly 
 
6) Plenum 
 
7) Plenum Filters x2 
 
 
 
 
 
 
 
 
 
 

FITTINGS & FIXTURES 

 
8) M8 Bolts x 4 
 
9) Hold Down Bars x 4 
 
10) Plenum Cover Screws x 4 
 
11) Self Tapping Screws x 6 
 

 
 
 
 
 
        1 
 
 
 
 
 
 
         2 
 
 
 
         3 
 
 
         4 
 
 
 
         5 
 
 
 
 
 
         6 
 
                                                                                                                                          7 
 

 
 
 
 
                             8                                        9                            10             11 
 

 

BEFORE INSTALLATION 

Ensure that the installation instructions have been properly read and understood 

Installation must conform nationally to wiring regulations and in particular AS3001 – 2008 

DO NOT attempt to modify or add components to the installation procedure 

This equipment must only be serviced by a licensed refrigeration mechanic 

If your installation varies from the method outlined please contact Aircommand for specialty advice 

 

WARNING 

Failure to properly install the unit or attempting to modify it in any way can be extremely hazardous and may result in property 

damage and/or personal injury 

 

Aircommand will not be held responsible for issues arising from incorrect or improper installation methods

 

Содержание Cormorant MKII

Страница 1: ...OWNERS MANUAL INSTALLATION COMMISSIONING OF UNIT SPECIFICATIONS OPERATING INSTRUCTIONS...

Страница 2: ...l GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifier gratuitement par notre agent de service tout d faut r sultant d un d faut de fab...

Страница 3: ...NG INSTRUCTIONS FOR CORMORANT MKII ROOFTOP AIRCONDITIONER Model Number Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before install...

Страница 4: ...V is parked in a shaded position In periods of extreme high temperature it is recommended to start the air conditioner earlier in the morning to greatly improve its ability to cope with the expected h...

Страница 5: ...Installation must conform nationally to wiring regulations and in particular AS3001 2008 DO NOT attempt to modify or add components to the installation procedure This equipment must only be serviced b...

Страница 6: ...ng could interfere with the discharge air flow from the plenum It is important that the unit is never more than 5 from the horizontal and the rear of the unit should never be higher than the front Con...

Страница 7: ...nected at the supply mains and or battery Failure to do so may result in personal injury or death TIP Always use crawl boards across the roof to avoid damage Fig 3 Shows an ideal roof structure with s...

Страница 8: ...w from under the roof Position the CORMORANT so the 4 mounting holes circled line up with the corners 5 ATTACH SPIGOT TO UNIT Screw spigot onto underside of unit with the 4 screws provided this step c...

Страница 9: ...SEMBLE DUCT Thread a hold down bar onto the M8 bolt and push the bolt almost all the way into the hole in each corner of the brace Fig 9 Leave a 10mm gap between the hold down bar and the recess in th...

Страница 10: ...d the spigot underneath the unit Fig 12 Then engage the four M8 bolts taking care to ensure the hold down bars slot into their recesses 10 ATTACH PLENUM COVER Connect the main cover of the plenum to t...

Страница 11: ...a very small pilot hole may need to be drilled to guide the screws into place Replace the return air filters by sliding them into the plenum until they click into place Your installation is now comple...

Страница 12: ...elderly Ensure that filters are cleaned in a safe and well ventilated area If a more thorough clean is required then the filters can be washed out using warm soapy water Care must be taken to avoid ri...

Страница 13: ...eating Capacity F L A Cooling F L A Heating Locked Rotor Amps Refrigerant Charge Inside Air Delivery Maximum Total Installed Weight 240V 50Hz Heatpump 240V 50Hz 3 5 KW 3 5 KW 5 6 A 5 2 A 32 A R410A 63...

Страница 14: ...will not re energize until the heat exchanger has warmed and then the fan will start to blow warm air DRY The DRY mode is used when the room temperature is close to comfortable but you wish to dehumid...

Страница 15: ...must be below room temperature NB The compressor has a 3 minute delay before starting Ensure mode has be switched to heat check green LED Thermostat set point must be above room temperature NB The co...

Отзывы: