11. ATTACH PLENUM COVER

 

 
- Secure the main plenum cover to the duct 
assembly  with  the  4  screws  provided  (Fig 
15).  

 
TIP: 

It  is  important  that  these  screws  are 

not  over  tightened  otherwise  the  plenum 
may crack. 
 
-  Remove  the  filter  elements  by  pulling 
them  out  of  the  plenum,  and  use  the  six 
self-tapping  counter  sunk  screws  to  secure 
the covers edges to the caravan ceiling (Fig 
16).  In  some  instances  a  very  small  pilot 
hole  may  need  to  be  drilled  to  guide  the 
screws into place. 
 
-  Replace  the  return  air  filters  by  sliding 
them  into  the  plenum  until  they  click  into 
place 
 
-Your installation is now complete. 
 

 
 
 
 
 
 
 
 
 

            

 
 
 
 
 

 

       Fig 14: Attaching the suspension cord will allow two hands free to plug in 

the control cable and affix the plenum 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                      
 
 

       Fig 15: Secure the main plenum cover to the duct assembly with the four 

screws provided 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

       Fig 16: Remove the plenum filters and use the six self-tapping screws to  

      secure the plenum over to the ceiling of the caravan. Be sure not to over tighten. 

 

 

INSTALLATION IS NOW COMPLETE 

Содержание Cormorant MKII

Страница 1: ...OWNERS MANUAL INSTALLATION COMMISSIONING OF UNIT SPECIFICATIONS OPERATING INSTRUCTIONS...

Страница 2: ...l GARANTIE DE CLIMATISATION R FRIG R E Garantie pour l Australie Nous nous engageons par cette garantie faire rectifier gratuitement par notre agent de service tout d faut r sultant d un d faut de fab...

Страница 3: ...NG INSTRUCTIONS FOR CORMORANT MKII ROOFTOP AIRCONDITIONER Model Number Serial Number Date Purchased WARNING It is important that this installation manual is properly read and understood before install...

Страница 4: ...V is parked in a shaded position In periods of extreme high temperature it is recommended to start the air conditioner earlier in the morning to greatly improve its ability to cope with the expected h...

Страница 5: ...Installation must conform nationally to wiring regulations and in particular AS3001 2008 DO NOT attempt to modify or add components to the installation procedure This equipment must only be serviced b...

Страница 6: ...ng could interfere with the discharge air flow from the plenum It is important that the unit is never more than 5 from the horizontal and the rear of the unit should never be higher than the front Con...

Страница 7: ...nected at the supply mains and or battery Failure to do so may result in personal injury or death TIP Always use crawl boards across the roof to avoid damage Fig 3 Shows an ideal roof structure with s...

Страница 8: ...w from under the roof Position the CORMORANT so the 4 mounting holes circled line up with the corners 5 ATTACH SPIGOT TO UNIT Screw spigot onto underside of unit with the 4 screws provided this step c...

Страница 9: ...SEMBLE DUCT Thread a hold down bar onto the M8 bolt and push the bolt almost all the way into the hole in each corner of the brace Fig 9 Leave a 10mm gap between the hold down bar and the recess in th...

Страница 10: ...d the spigot underneath the unit Fig 12 Then engage the four M8 bolts taking care to ensure the hold down bars slot into their recesses 10 ATTACH PLENUM COVER Connect the main cover of the plenum to t...

Страница 11: ...a very small pilot hole may need to be drilled to guide the screws into place Replace the return air filters by sliding them into the plenum until they click into place Your installation is now comple...

Страница 12: ...elderly Ensure that filters are cleaned in a safe and well ventilated area If a more thorough clean is required then the filters can be washed out using warm soapy water Care must be taken to avoid ri...

Страница 13: ...eating Capacity F L A Cooling F L A Heating Locked Rotor Amps Refrigerant Charge Inside Air Delivery Maximum Total Installed Weight 240V 50Hz Heatpump 240V 50Hz 3 5 KW 3 5 KW 5 6 A 5 2 A 32 A R410A 63...

Страница 14: ...will not re energize until the heat exchanger has warmed and then the fan will start to blow warm air DRY The DRY mode is used when the room temperature is close to comfortable but you wish to dehumid...

Страница 15: ...must be below room temperature NB The compressor has a 3 minute delay before starting Ensure mode has be switched to heat check green LED Thermostat set point must be above room temperature NB The co...

Отзывы: