(Vers. 10.26.2017)
Page 10 of 24
Series (E) Refractory Walled Air Curtain Burner (Electric Motor & VFD)
OPERATING MANUAL
SITE PREPARATION
THE GOALS TO GOOD SITE PREPARATION ARE:
To place the wood piles for easy access.
To sort the waste wood pile.
To organize the inflow of new wood waste.
When locating the FireBox;
Consider access for your truck and trailer to load and unload the FireBox. Ensure
there is enough room to maneuver your truck and trailer.
Consider where the waste piles will be located. We generally recommend two waste
piles (explained in next section).
Consider the predominate wind direction. Hot embers
will be
escaping from the Fire-
Box during all burning operations.
Consider the available 480V three
-
phase power pole connection and underground
feed to the FireBox from there. Power to be supplied pursuant to Local Code.
DANGER:
This machine DOES NOT prevent hot embers from es-
caping. This machine is designed primarily as a pollution control de-
vice to reduce the smoke (particulate matter) generated from burning
clean wood waste.