Series (E) Refractory Walled Air Curtain Burner (Electric Motor & VFD)
OPERATING MANUAL
HOW TO SET UP THE MACHINE
C) STARTING
Electric Motor and VFD
Ensure that the ground wire is properly con-
nected to the grounding lug (See Page 23)
and the grounding rod.
Ensure that the power on the main external
breaker or switch is turned on.
Insure that the Fan Speed Switch is placed in
Position OFF.
Insure the RED POWER BUTTON is OFF
(pushed in).
Set the Main Power Switch to the ON position;
this will connect power to the unit. Wait 15
seconds for the VFD to boot up before going
to the next step.
Pull out the red POWER BUTTON
(ON Position).
Load FireBox and start fire per Operating
Manual Page 13.
Set FAN SPEED to Position NORMAL 2.
Once the machine is fully operational, you
may select Position NORMAL 1 for energy
conservation, as long as this does not result in
excessive particulate (smoke) release.