USER MANUAL
VACUUM BLASTING MACHINE 1070 PNE
AIRBLAST
Revision 1 January 2012
page 10.2
Manual cleaning of the filters ("back flush")
Clean the filters as described below:
*
Close the main air valve .
*
Press and release the button on the control panel one time. The two filters will be
cleaned and after a few seconds the dust from this filter is set in the bottom of the dust
storage tank.
*
The dust stored in the bottom of the tank may be removed by opening the large butterfly
valve at the bottom. Make sure that a dust bag is attached to the pipe!!.
*
Make sure that after emptying the tank the butterfly valve is closed completely.
A leaking valve causes loss of suction power and will damage the valve.
*
The dust bag should regularly be emptied or replaced.
*
Wear a respirator during dust bag replacement.
Содержание 1070 PNE
Страница 1: ...OPERATOR S MANUAL AIRBLAST 1070 PNE VACUUM BLASTING MACHINE ...
Страница 15: ......
Страница 21: ......
Страница 33: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 5 ...
Страница 34: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 6 ...
Страница 35: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 7 ...
Страница 36: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 8 ...
Страница 37: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 9 ...
Страница 38: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 10 ...
Страница 39: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 11 ...
Страница 40: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 11 ...
Страница 41: ...USER MANUAL VACUUM BLASTING MACHINE 1070 PNE AIRBLAST Revision 1 January 2012 page 12 11 ...