Replacing the filters
1. Pre-filter
2. Cold-catalyst filter / High effection formaldehyde removing filter
3. Antibacterial / True HEPA filter
The appliance has filter change reminding function. It's set at 1500 hours. Please replace Formaldehyde/
Cold catalyst filter (no. 2) and Antibacterial/HEPA filter (no. 3) when “change” icon light up. Also
please press the child lock button for 5 seconds to reset this function.
A) Press the middle of front to make the upper button out of its position.
B) Pull out the front panel.
C) Take out the filters one by one.
D) Fill in new filters one by one in a correct order.
Replacing UV lamp
UV lamp need to replace 1x during 2-3 years according its usage.
How to replace UV lamp:
•
Unplug appliance from el. socket, remove front cover and take out
all filters.
•
Put flat-blade screwdriver under cover of UV lamp (from bottom
left side about 8 cm - 5
th
rib of cover) and slide it to right side
slowly until you release safety lock. After that you can pull left
side of UV lamp little bit. In this moment you can pull UV lamp
from contacts on right side (in direction to left).
•
Insert UV lamp firstly to contacts on right side and then push left
side to back of panel until you hear crack sound.