INTRODUCTION 

Overview 

Thank you for choosing VertEx as your fume or dust control system. Please read this document before 
installation and use. 

This document details maintenance activities which are essential to the safe use of your VertEx. We 

recommend that the Responsible Person reads this manual fully prior to installation and operation of the 
VertEx. 

This document refers to the VertEx range. Models of this type are available with a range of filter configurations. 

The filter configuration in use is detailed on the system Commissioning Certificate and is used within this 
document to provide filter-specific maintenance information. 

About VertEx 

VertEx is a self-contained cross draught extraction system which utilises a fan and filter combination selected 
for your specific application, to extract and filter dust/fumes and return filtered air to the work place. 

Some models vary in filtration and filtered air delivery point. 

Filters are cleaned by pulsing clean air against the air flow, knocking dust off into the removable bins in the 
base of the AirBench 

It is used by running the fan at either fixed speed or variable speed (if speed controller fitted) to draw the 

pollutant away and through the filters, allowing work or the process to proceed next to the face. 

About this Document 

This document provides general maintenance and operation instructions for the VertEx range. It should be 

read in conjunction with the Commissioning Certificate supplied with the unit. If you have any concerns or 
doubts about maintenance or operation of this unit, contact the manufacturer. 

© Copyright AirBench Ltd 2016

Page 

!

 of 

!

4

16

Содержание Vertex VP

Страница 1: ...rtex VP Operation and Maintenance This Edition 2 October 2018 AirBench Ltd 14 Grange Farm Road Colchester CO2 8JW www airbench com 44 0 1206 791191 Copyright AirBench Ltd 2016 Page of 1 16 AIRBENCH LT...

Страница 2: ...ENERAL 7 IN HOUSE COMMISSIONING 7 Operation 8 PRIOR TO USE 8 GENERAL USE 8 Maintenance 9 FILTER CARE 9 SPARES 10 OTHER ROUTINE MAINTENANCE 11 Accessories 12 FILTER PRESSURE GAUGES 12 HOURS RUN METER 1...

Страница 3: ...ach unit is marked with its design application which is also shown on the commissioning certi cate The lters are not self cleaning They must be maintained cleaned replaced as described within Do not m...

Страница 4: ...ystem which utilises a fan and lter combination selected for your speci c application to extract and lter dust fumes and return ltered air to the work place Some models vary in ltration and ltered air...

Страница 5: ...position the top section on the base section always ensure operators are fully trained and that other users are outside the working zone of the forklift Once loosely positioned ensure mounting holes a...

Страница 6: ...ceiver of 5l volume within this unit Ducted Units As standard VertExes are con gured to discharge upwards through the top of the unit without ductwork Ducting should not be retro tted to the discharge...

Страница 7: ...the lter maintenance routine required for this machine Once complete you should note this on the commissioning certi cate and retain the certi cate for future reference As operating conditions vary e...

Страница 8: ...gauge is showing in the upper red zone check the lter condition they may require cleaning or replacement This can also be checked against the lter inspection pressure drop readings in the Commissioni...

Страница 9: ...nying log sheet MAIN FILTER ACCESS Main Cartridge Filters are accessed by turning the quarter turn latches on the front cover to loosen and opening the front panel Filters can be released by undoing t...

Страница 10: ...See the speci c list for your machine shown on the commissioning certi cate When ordering please contact the manufacturer quoting the serial number of this machine Copyright AirBench Ltd 2016 Page of...

Страница 11: ...f moisture If moisture is present within the tank stop and have it examined by a specialist FILTER SEALS These sit behind the lters and prevent dust passing into the body of the bench and the exhaust...

Страница 12: ...switch is powered Wheels Standard industrial rubber wheeled swivel castors are used The two front wheels are lockable Lock by pressing on the lever and trip by icking models and operation vary slight...

Страница 13: ...ed and recorded within the system logbook Condition check of fan lters electrics Performance testing according to recommended face velocities Visual check that operators are working within effective a...

Страница 14: ...TECHNICAL Arrangement 1274 700 2465 1392 Copyright AirBench Ltd 2016 Page of 14 16...

Страница 15: ...nal HEPA outlet lter Check the Commissioning Certi cate for details speci c to your unit Model Width Height Depth Nominal Vent Height Weight Fan Power Max Current mm mm mm mm kg kw a VP121218 1270 246...

Страница 16: ...achines general requirements EN 60335 2 80 Safety requirements for electric fans and regulators We AIRBENCH Limited declare that VertExes when supplied as self contained equipment comply with the dire...

Отзывы: