background image

AirBench

DECLARATION OF CONFORMITY 

BY 

AIRBENCH LIMITED 

Relevant Directives 

EMC Directive 2004/108/EC (when connected to standard mains sinusoidal supply). 

Low voltage Directive 2006/95/EC 

-  EN-60204–1:2006  (Safety  of  machinery,  electrical  equipment  of  machines,  general 
requirements). 

- EN-60335-2-80 (Safety requirements for electric fans and regulators). 

We;  AIRBENCH  Limited,  declare  that  “MF600”  when  supplied  as  self  contained 
equipment  complies  with  the  directives  detailed  above  and  therefore  comply  with 
requirements of the Low Voltage Directive. 

Business Name:

AirBench Ltd. 

14 Grange Farm Road, 

Colchester, 

Essex. 

CO2 8JW

Responsible Person:

Simon Cook

Description:

Media Filter Unit known as “MF600”

Page 

!

 of 

!

7

7

Содержание MF600

Страница 1: ...AirBench MF600 Operation and Maintenance This Edition 6 September 2016 AirBench Ltd 14 Grange Farm Road Colchester CO2 8JW www airbench com 44 0 1206 791191 Page of 1 7 AIRBENCH LTD ...

Страница 2: ...FOR USE 3 Prior to Use 4 PREPARATION 4 INSTALLATION 4 ELECTRICAL CONNECTIONS 4 Operation 5 PRINCIPLE OF OPERATION 5 CONTROLS 5 FILTER REPLACEMENT 5 LOG BOOK 5 FILTER ACCESS 6 FAULT FINDING 6 Support 6 DECLARATION OF CONFORMITY 7 Page of 2 7 ...

Страница 3: ...e Always make sure that good access is provided for the maintenance of the MF600 The MF600 must not be used in an environment where there is a risk of explosion from dust or gases in explosive concentrations The MF600 must only be used for the designated application Contact us before change of use The MF600 must not be used without filters Always isolate the mains power before changing filters or ...

Страница 4: ...kg The unit must be installed on a suitable level floor or mount that is able to support its weight Before installation check that adequate space is available for replacement of filters ELECTRICAL CONNECTIONS The unit is prewired to a standard 13a mains cable This may be replaced if required by removing the cover of the control panel Take care not to pinch the electrical cables Switch on unit prio...

Страница 5: ...er on off 2 RED LIGHT Advises filter over pressure 3 WHITE LIGHT Power on FILTER REPLACEMENT When filter 1 is full it can be emptied Remove the filter from the housing and either vacuum gently or tip loose dust into a skip Wear appropriate PPE when performing filter maintenance Filter 2 must be replaced when full LOG BOOK A log book is supplied with this unit It should be used to record routine an...

Страница 6: ...01206 791191 Fax 01206 791091 Web www airbench com Email sales airbench com Fault Remedy Lack of Suction Dirty filters see page 5 Motor does not operate Mains fuse tripped Fan discharge air is contaminated The filtration system is being by passed Check for damage or incorrectly fitted filter s and replace as appropriate Always isolate the mains power before changing filters or removing any compone...

Страница 7: ...achines general requirements EN 60335 2 80 Safety requirements for electric fans and regulators We AIRBENCH Limited declare that MF600 when supplied as self contained equipment complies with the directives detailed above and therefore comply with requirements of the Low Voltage Directive Business Name AirBench Ltd 14 Grange Farm Road Colchester Essex CO2 8JW Responsible Person Simon Cook Descripti...