PROBLEM
POSSIBLE CAUSE
SOLUTION
Blower will not start
Insufficient Pressure
Check pressure gauge on compressed air source to
ensure proper supply pressure. Turn regulator knob
clockwise to increase air pressure to air motor and
note the gauge pressure on the regulator
Excessive vibration
Possible internal damage
Turn blower off and inspect fan blades, shaft, and
housing for debris, damage, and loose screws.
Note: Never run blower for extended periods without
ducting installed on the exhaust flange
Possible external damage
Turn blower off and inspect housing and frame for
cracks or loose screws.
Blower loses pressure
Insufficient air flow or pressure
Check for kinked supply hose or damaged duct.
Motor icing (interior)
High humidity
Install moisture separator filter before blower (order
Model # PF-240). Remove muffler and clean out ice
blockage and reassemble.
Model #
SVB-A8
Motor
4 HP pneumatic (intrinsically safe)
Pressure Required
10 - 100 PSI
Air Consumption
5 - 85 CFM
Inlet/Outlet Size
8” Diameter
Flow Rate
Free air: 1500 CFM at 10 PSI / 3000 CFM at 100 PSI
25’ duct w/one 90° bend: 1040 CFM low / 1725 CFM high
25’ duct w/two 90° bends: 870 CFM low / 1295 CFM high
Weight
61 lbs.
Noise Level
82 dbA @ 3 ft. @ 80 PSI inlet pressure
11
troubleshooting
Specifications - Model: SVB-A8