TROUBLESHOOTING 

If your unit is not operating as expected, there are several steps you can take to attempt 

to correct the problem. 

WARNING: 

Do Not

 attempt to operate the UV-C lamp outside of the unit. UV-C 

radiation is extremely harmful to unprotected skin and eyes. 

If the Bulb is not operating: 

- Inspect the unit and the power cable to verify nothing appears damaged.

- Check that the selected power source is providing power for the unit.

- Check that both ends of the 10’ power cable are securely connected to either the

unit or the power source.

- Check that the On/Off switch is flipped to the on position.

- Once airflow is established, the lamp indicator light will be lit.

If the Lamp Operating LED is Red, the bulb has expired. Contact your local distributor or 

Air Sniper to replace the unit. 

REPLACING YOUR UNIT

The Air Sniper Spectrum-800 unit uses a built in 300W UV-C lamp with a lifetime of 6+ 

years (55,200 hours, based on 24/7 operation). To track the life of the lamp on your unit, 

check the bulb status LED Color when the unit is activated to determine the state of 

your unit. It is strongly recommended that the unit be replaced when the lamp life 

warning LED is illuminated (LED glows yellow). When the lamp life has been exceeded 

(LED glows red), the entire unit will need to be replaced. Contact your local distributor or 

Air Sniper to order replacement units. 

Содержание Spectrum-800

Страница 1: ...1 Air Sniper Spectrum 800 USER MANUAL...

Страница 2: ...anual and follow installation recommendations An authorized Air Sniper dealer will know the system best and if service or maintenance is needed the Air Sniper team is here to help Our team is dedicate...

Страница 3: ...ply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 7 This appliance contains a UV C emitter UV C lamps contain smal...

Страница 4: ...2 IMPORTANT SAFETY INSTRUCTIONS 3 TABLE OF CONTENTS 4 ABOUT THE SPECTRUM 800 UNIT 5 DESIGN 5 FEATURES 6 SPECIFICATIONS 6 INCLUDED PARTS 7 DIRECTIONS FOR USE 8 BULB STATUS 9 FILTER REPLACEMENT 9 TROUB...

Страница 5: ...n North America Find the test results here https airsniper ca test results For more information on the Spectrum 800 unit and all other Air Sniper products and services call 1 888 338 9549 to speak to...

Страница 6: ...Systems On Off switch airflow differential pressure switch sensor Bulb Life 55 200 Bulb life hours of high intensity UVC Electrical Safety Certification ETL certified for USA and Canada Ozone Complia...

Страница 7: ...7 INCLUDED PARTS Included in the package you will find 1 Air Sniper Spectrum 800 unit 2 10 Power cable 3 AC Infinity fan user manual 4 MERV 8 filter 1 2 3 4...

Страница 8: ...supplied power cable to the unit The connector end for the cable is found on the back of the unit 2 Insert the MERV8 air filter from the front ensuring that the direction of the filter is correct To e...

Страница 9: ...espan requires replacement in near future Red Lamp life exceeded lamp has reached the end of its lifespan requires immediate replacement When the Lamp Operating LED color is yellow please contact your...

Страница 10: ...pped to the on position Once airflow is established the lamp indicator light will be lit If the Lamp Operating LED is Red the bulb has expired Contact your local distributor or Air Sniper to replace t...

Страница 11: ...s purchased together with a copy of the bill of sale or dated proof of purchase thereof and the Return Authorization Number or 2 Ship the defective Air Sniper unit directly to Air Alpine Innovative Re...

Отзывы: