construct some type of framing strong enough to
support the weight of the CM-12.

The CM-12 may also be mounted using 3/8” [10 mm]
diameter threaded steel rods available in many
hardware stores.  Four steel rods will be required.

WIRING

The 120V, 60 Hz CM-12 has a standard three-prong
plug on a 10 foot [3 m] power cord.  It requires only a
standard grounded outlet for electrical power.  Route
the power cord so that it will be out of the way of the
building’s occupants.

PERMANENT WIRING

To permanently wire the CM-12, follow these
instructions exactly.  All wiring must comply with
applicable codes and ordinances.  Wire the CM-12
using the built-in junction box.  It is recommended that
No. 14 gauge or heavier wire be used to complete the
wiring from the junction box to the external power
source.  However, be sure to comply with local codes.

1.  Open the inlet grille of the CM-12 and remove the

primary particle filter by supporting the filter near
the turnstiles and rotating the two turnstiles to the
open position.

2.  Remove the access panel inside the CM-12

cabinet.  This panel is the galvanized unpainted

panel on the side the door opens from.  This will
allow you access to speed control wires.

3.  Disconnect and discard the power cord, the

solderless connectors and strain relief.  Plug the
power cord hole with the plug provided.

4.  Run conduit from the power supply to the

appropriate knockout.  Fish wires to the speed
control wires in the junction box.  Note that you
may gain better access to the junction box within
the cabinet through the discharge end of the air
cleaner.  This can be accomplished by removing
the discharge louver with a Philips screwdriver and
removing the carbon filter.

5. 

Connect lead wires with solderless connectors
including ground (green) wires.  Proper grounding
of this device is mandatory for correct operation
and safety.

ELECTRICAL INSTALLATION

CAUTION!

Persons qualified to install electrical wiring
should only attempt this procedure.  All wiring
must comply with applicable codes and
ordinances.

1.  Double check that the rating on the air

cleaner is consistent with the power source,
either 120 Vac, 60 Hz or 208-240 Vac, 50/
60 Hz.

2.  Run three No. 14 gauge (or heavier) wires

through conduit to the wiring compartment
on the air cleaner.  The green wire should be
attached to the external ground.  The black
and the white wires are the power conduc-
tors.  The connections are shown in Fig. 2.

REASSEMBLE

1.  Install the two carbon filter modules into the two

discharge cavities.  Make sure the support clips
are in place before letting go of the filter modules.

Caution must be used when handling the filter
modules.  They weigh approximately 40 lbs.
when new.

2.  Screw the exhaust grille louvers to the air

cleaners.  This must be done after the carbon filter
modules are installed.

3.  Install the primary filter so that the airflow arrow

points up into the ceiling.  Turn the two turnstiles
so that they properly support the filter.

4.  Hang the intake grille.  Position the prefilter and

latch the intake grille into place.

5.  Clean up the installation area.

Содержание MiracleAir CM-12

Страница 1: ...rom Air Quality Engineering Inc is the ultimate solution for indoor air pollution capturing both particulate and gaseous contaminants Odors tobacco smoke pollen dust vapors and many other irritants ar...

Страница 2: ...2 TABLE OF CONTENTS PAGE SPECIFICATIONS 3 PLANNING THE INSTALLATION 3 ELECTRICAL INSTALLATION 5 ELECTRICAL SCHEMATIC 6 CHECKOUT 7 MAINTENANCE 7 PARTS LIST DIAGRAM 9 WARRANTY 10...

Страница 3: ...ersion has two modules each containing 10 disposable panels for a total carbon weight of 22 lbs PLANNING THE INSTALLATION WARNING EXPLOSION HAZARD Can cause property damage severe injury or death 1 Do...

Страница 4: ...x H of Room x Air Changes Hr of CM 12 s CFM of Air x 60 Min CHOOSE LOCATION To ensure even air distribution the CM 12 draws air into the center of the air cleaner and discharges air in four directions...

Страница 5: ...n the junction box Note that you may gain better access to the junction box within the cabinet through the discharge end of the air cleaner This can be accomplished by removing the discharge louver wi...

Страница 6: ...6 ELECTICAL SCHEMATIC...

Страница 7: ...er inspecting the unit for a one or two month time period you will have established the proper cleaning interval for the prefilter When the MiracleAir unit no longer removes odors from the air it is t...

Страница 8: ...arge ends of the air cleaner The filters are resting in tracks inside the cabinet There is no locking mechanism to release REPLACING THE ODOR VAPOR FILTERS OF THE CM 12 DELUXE UNITS The standard Mirac...

Страница 9: ...9 PARTS LIST AND DIAGRAM...

Страница 10: ...EPAIR A showing by the original purchaser that the Product has not been altered repaired or serviced by anyone other than an authorized service technician using genuine AQE parts 4 UNAUTHORIZED PARTS...

Отзывы: