background image

 

11 

INST APD0344 A090630

 

12 

INST APD0344 A090630

+

+

+

Detector

#1

Detector

#2

Detector

#X

AL

1

S/H

AL2

AL2

iNDiviDUAL HORN/STROBe UNiTS

All alarm relays operate with single alarm.  

Individual horn/strobe units operate on  

alarmed detector only. 30 detectors max.

AL

1

AL

1

AL

1

AL2 AL2

S/H

S/H

iNTeRCONNeCTiON  wiRiNG FOR COMMON FUNCTiONS

iNTeRCONNeCTiON  wiRiNG FOR COMMON FUNCTiONS

 

NOTE

:  

A common power 
supply must 

be used for 

all

 

interconnected 
detectors.

 

NOTE

:  A common power supply must be used for 

all

 interconnected detectors.

Detector

#1

Detector

#2

Detector

#X

COMMON TeST/ReSeT

 30 detectors max.

(Use normally open test/reset switch)

T/R

T/R

T/R

T/R

AL2 AL2

AL2 AL2

AL2

COMMON SHUTDOwN

All alarm relays operate with single alarm. 

 30 detectors max.

AL

1

AL

1

AL

1

AL

1

AL2 AL2

AL2 AL2

AL2

Detector

#1

Detector

#2

Detector

#X

+

+

+

COMMON HORN/STROBe UNiTS

All alarm relays operate with single alarm.  

All horn/strobe units operate on any single  

alarm. 10 detectors max.

AL

1

AL

1

AL

1

AL

1

AL2

AL2

AL2 AL2

S/H

S/H

S/H

S/H

S/H

S/H

S/H

Detector

#1

Detector

#2

Detector

#X

DeTeCTOR iNTeRCONNeCT

AL1

AL2

T/R

S/H

COMMON

  

(+) 

ALARM

 LINK

COMMON

  

(+) 

LINK

 REFERENCE

COMMON

  

(+) 

TEST

/RESET

 IN

(+) 

ALARM

 OUT

(–) 

ALARM

 OUT

COMMON  

ALARM HORN/STROBE 

OPTIONS

The following diagrams show interconnection of the RT-3000 Series to other duct smoke 

detectors manufactured by Air Products and Controls, specifically the SL-2000 Series, the 
HS-100 Special Application Series and the SM-501 Series. Up to 30 Air Products units as 

described here can be part of your interconnected system.

COMMON SHUTDOwN

All alarm relays operate with single alarm. 30 detectors max.

AL

1

AL

2

12

20

20

12

20

20

12

12

AL

1

7

7

AL

1

7

7

AL

1

AL

1

16

18

18

16

18

18

16

16

RT-3000

RT-3000

RT-3000

RT-3000

RT-3000

RT-3000

SL-2000

SL-2000

SL-2000

SL-2000

SL-2000

SL-2000

HS-100

HS-100

HS-100

HS-100

HS-100

HS-100

SM-501

SM-501

SM-501

SM-501

SM-501

SM-501

AL

1

AL

1

AL

2

AL

2

AL

1

Detector

#1

Detector

#2

Detector

#X

AL

2

COMMON TeST/ReSeT

30 detectors max. (Use normally open test/reset switch)

T/R

1

15

20

RT-3000

RT-3000

RT-3000

SL-2000

SL-2000

SL-2000

HS-100

HS-100

HS-100

SM-501

SM-501

SM-501

Detector

#1

Detector

#2

Detector

#X

AL

2

20

20

20

20

7

7

7

7

21

21

21

21

RT-3000

RT-3000

RT-3000

SL-2000

SL-2000

SL-2000

HS-100

HS-100

HS-100

SM-501

SM-501

SM-501

AL

2

AL

2

AL

2

T/R

T/R

T/R

1

1

1

15

15

15

20

20

20

Содержание RT-3000-N

Страница 1: ...t Any example applications shown are subject to the most current enforced local national codes standards approvals certifications and or the authority having jurisdic tion All of these resources as well as the specific manufacturer of any shown or mentioned related equipment should be consulted prior to any implementation For further information or assistance concerning this product contact Air Pr...

Страница 2: ...d into the HVAC duct Air flowing through the duct is forced into the air intake inlet tube via the air intake holes facing the airflow and passes over the detector head The air will be drawn out via the exhaust tube back into the HVAC duct A 7 exhaust tube is provided in the installation kit When the concentration of smoke particles suspended in the air stream reach the alarm threshold of the dete...

Страница 3: ...be into place against the spring loaded retainer and turn to the correct position allowing the key to Mechanical Installation lock the tube in the desired orientation For front side installation simply rotate the tube retainer so that the tube may be inserted and oriented properly Once the tube is installed rotate the retainer back into place to lock down the tube Ensure air intake sampling tube i...

Страница 4: ...VER REMOVAL and the unit will be energized The green pilot LED will be illuminated and when pressing the test reset button TEST RESET the red alarm LED will be illuminated This test confirms the correct basic operation of the duct smoke unit excluding the detector head see functional testing Shut down WIRING Example In alarm NC and COM will open interrupting voltage supply to fan NC COM NO ALARM 1...

Страница 5: ...nly no tools single point cover assembly when the unit cover is on and the latch is in closed position the RT 3000 is secure and weathertight Patented Maintenance Mode offers 3 minute interval for test and maintenance functions with no extra trouble reports to the system automatically shuts off when cover latch engages Patented tether holds cover to unit and allows hands free reference to wiring d...

Страница 6: ...ACU Alarm COM NO COM NO COM NO COM NO facu alarm trouble NO com nc com NO C NC C form A Alarm form b trouble 30vdc 1 0a 30vdc 7 0a SAMPLE CONTROL unit WIRING STYLE d CLASS A IDC Supervised A fault condition will not inhibit an alarm response Trouble contacts are shown in energized condition Under normal operation contacts will be held as shown msr remote accessory wiring ms remote accessory wiring...

Страница 7: ...interconnect al1 al2 t r s h common alarm link common link reference common test reset in alarm out alarm out common alarm horn strobe options The following diagrams show interconnection of the RT 3000 Series to other duct smoke detectors manufactured by Air Products and Controls specifically the SL 2000 Series the HS 100 Special Application Series and the SM 501 Series Up to 30 Air Products units...

Страница 8: ...afe to perform test maintenance functions without extra reports to the system Determine Correct Operation ofthe Head MagnetTest 1 Place the square short sided end of the magnet provided with the installation kit on the grey section of the housing inline with the area designated Test Magnet Allow at least five seconds for alarm initiation 2 Upon alarm initiation both the detector head LED and redAL...

Страница 9: ...combination Strobe Visual and Sounder Audible MSR 50SA X C Module Clear Lens with color Double Gang Cover Plate MSR 50SA X O Module Opaque Lens with color Double Gang Cover Plate MS and SHP SERIES REMOTE ACCESSORIES MS RA Remote Alarm MS RA R Remote Alarm push button Test Reset Switch MS RA P R Remote Alarm Pilot push button Test Reset Switch MS KA R Remote Alarm key operated Test Switch MS KA P R...

Отзывы: