Maintenance and Customer Service

Placement and Operation

Optional Cleaning

If you require any additional information or have problems with your Air Oasis ap-

pliance, you may call Air Oasis customer service at:

1-800-936-1764

Please have your serial and model numbers, found on bottom of unit, handy when 
calling.
Save your sales receipt to show if your Air Oasis appliance should ever need any 

Off / On

Switch

Base and Honeycomb 

- We 

recommend wiping with a dry towel to 

remove dust and build up.

Aluminum Shell

 - We recommend 

using stainless steel/aluminum spray 

on polish or multi-surface cleaners.  

Make sure the polish or cleaner is 

recommended for use on aluminum.

Internal

 - Take dry cloth and wipe 

inside the shell and around the 

aluminum brackets and the ballast or 

spray with compressed air.

NOTE:  

Use compressed air only 

to clean AHPCO Cell.  Any removal 

of catalyst coating will decrease the 

effectiveness of your unit and void the 

warranty.

Bi-Polar Brush Heads 

- The Bi-Polar 

brush heads inside your unit should 

be cleaned periodically to remove any 

debris for optimal effectiveness.

For best results the unit should 

be placed in a central location 

and three feet or higher from the 

ground.
Operation is very simple.  Remove 

the Air Oasis from the packaging.

Place in desired location, plug it 

in and rock the switch to the on 

position.  The unit can remain in 

the on position 24/7.
Upon startup you will hear 3 beeps 

signifying the unit has power. After 

a brief delay AHPCO

®

 Cell will 

illuminate and you will see a blue 

glow inside the unit. 

4

Make sure that the power 

cord is unplugged prior 

to cleaning.

Содержание 1000G3

Страница 1: ...ions Troubleshooting Tips Cleaning and Maintenance Tips For use with models 1000G3 3000G3 3000XG3 Before operating this unit carefully read the contents of this manual Due to continuous improvements t...

Страница 2: ...ully before operating your air purifier Table of Contents Safety Instructions and Cautions 2 Warranty 3 Maintenance and Customer Service 4 Placement and Operation 4 Cleaning 4 AHPCO Cell Replacement 5...

Страница 3: ...ers at www earth911 org If the UV lamp is broken do not touch the cell or glass with your hands UV lamp may be hot and could cause serious burns if not handled properly Please wait until the AHPCO Cel...

Страница 4: ...s not been subjected to physical abuse chemical exposure water damage damage caused by acts of God the use of voltages other than indicated on the label displayed on this product or service of this pr...

Страница 5: ...ide the shell and around the aluminum brackets and the ballast or spray with compressed air NOTE Use compressed air only to clean AHPCO Cell Any removal of catalyst coating will decrease the effective...

Страница 6: ...he AHPCO Cell and pull to the side then remove the lamp connector 2 Use a phillips head screwdriver to remove the screws from the AHPCO Cell CAUTION UV lamp may be hot and could cause serious burns if...

Страница 7: ...to tighten the screws to secure the AHPCO Cell 6 Slide shell down onto base and replace screws Cord and switch are to the back 6 4 Plug in the AHPCO Cell slide the reset switch Your unit will beep in...

Страница 8: ...ingle Beep Repeated Slowly The AHPCO Cell has Expired Replace the AHPCO Cell Purifier doesn t seem to be working to optimal efficiency Purifier is being operated in areas with a high concentration of...

Отзывы: