background image

13

en

Operation AOS 7147

A) On/Off Button

You can switch the unit on or off by pressing button A. This 

button is also used to reset the cleaning indicator light (by 

holding down).

B) Hygrostat (setting the humidity level)

By pressing button B you can set the desired humidity level 

from 30% to 80% or CO (continuous operation).  A relative 

humidity between 40 and 60% is recommended. The ac-

curacy of measurement is +/- 5%.  The unit will switch off 

when the moisture level exceeds the desired setting. During 

selection the target value is displayed (

symbol DESIRED

).  

The display will automatically show the current value after 

a few seconds (

symbol CURRENT

). 

C) Timer

Using  button  C,  the  operation  time  can  be  set  adjusta-

ble between 1 and 8 hours or CO (continuous operation). 

Symbol G

 shows the operating period that has been set 

(1h/2h/3h/4h/5h/6h/7h/8h/CO). The display will automati-

cally show the current humidity after a few seconds. 

D) Mist output (regulating mist output)

By repeatedly pressing button D you can control the mist 

output. 

Symbol H

 shows which of the three levels (low/

medium/high) you have selected.

E)  Operation with pre-heating (warm mist)

Button E is used for switching the pre-heating on and off 

(

symbol I

 lights up).  As a result, the water is pre-heated 

to a temperature of 176 °F (80 °C)  before entering the 

nebulizer space. It takes approx. 10 to 15 minutes for the 

water in the base to warm up. The mist now leaves the 

humidifier at a pleasant temperature of 104 °F (40 °C).  The 

advantage of this is that the room temperature does not 

drop  and,  in  addition,  it  significantly  improves  the  water 

quality maintenance. 

F)  Automatic mode and Sleep mode

The automatic and sleep modes can be activated by pres-

sing button F. By pressing the button once, the automatic 

function is switched on (

symbol J

 appears on the display), 

maintaining the optimum humidity subject to the tempera-

ture. Control takes place by means of output quantity and 

pre-set target value. By pressing the button twice, the sleep 

function is switched on (

symbol K

 appears on the display), 

the target humidity is 50 – 65%; the operation time is set 

at 6 hours and the heating is switched on. In addition, the 

output quantity is also controlled subject to the difference 

between the target value and the actual value.

The hygrostat and mist output settings cannot be changed 

in either mode. If the buttons B or D are pressed, the unit 

will no longer be in auto or sleep mode.

G) Timer Indicator
H) Mist Output Indicator

I)  Pre-heating Indicator
J)  Automatic Mode Indicator
K) Sleep Mode Indicator
L)  Empty indicator

The water level is easy to see, thanks to the transparent 

water tank. The appliance also alerts you when the water 

tank is empty. The empty indicator is illuminated (symbol L). 

Please read the chapter «Filling the tank» for more informa-

tion. The symbol L may stay illuminated for some seconds 

with a refilled tank until the base is filled with water.

M) Cleaning indicator

If symbol M «CLEAN» appears on the display, the appliance 

should be cleaned as recommended by the manufacturer. 

This symbol comes on automatically every 2 weeks, de-

pending on the level of use. 

The display can be reset by 

holding down button A until the light disappears.

D

E

F

H

I

J

L

A

B

C

G

K

M

Содержание AOS U650

Страница 1: ...TIONS LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES AOS 7145 7147 Service Questions Contact Air O Swiss at 800 336 0326 Sales Inquiries Contact Sylvane at 8...

Страница 2: ......

Страница 3: ...3 Instructions for use 5 22 en Instructions d utilisation 23 40 a fr Instrucciones para el uso 41 57 a es...

Страница 4: ...4...

Страница 5: ...5 en Instructions for use...

Страница 6: ...over Never pull the plug from the outlet by the cable or with wet hands Do not use the appliance where combustible gases or vapors are present Do not expose the appliance to rain or use near water in...

Страница 7: ...7 en 5 1 3 7 9 6 2 4 8...

Страница 8: ...ral information A comfortable atmosphere indoors is reached with a rela tive humidity level between 40 and 60 Your humidifier automatically controls the humidity level according to the desired setting...

Страница 9: ...tion of the appliance Mist outlet rotating Evaporation chamber Water tank Demineralization cartridge Main body Control panel Water tank cap Hydro Stick Power Plug Membrane Brush Nebulizer space Water...

Страница 10: ...exchange the water and empty the water from the base before using the humidifier On average the demineralization cartridge should be replaced every 2 3 months depending on your water hardness Some ar...

Страница 11: ...14 Make sure that no foreign objects are in the water tank Fill the tank with clean cold water from the tap 15 Close the cap of the water tank securely place the wa ter tank onto the base 16 The wate...

Страница 12: ...vertical position The accu racy of measurement is 5 The unit will switch off when the moisture level exceeds the desired setting The appliance does not switch off if the switch is turned all the way t...

Страница 13: ...perature does not drop and in addition it significantly improves the water quality maintenance F Automatic mode and Sleep mode The automatic and sleep modes can be activated by pres sing button F By p...

Страница 14: ...cket for 32 oz of water Do not change the ratio Do NOT run the unit when using EZCal This can cause damage to the product and voids the warranty Thoroughly rinse the base with tap water after using EZ...

Страница 15: ...midifier s functionality while providing fresh humidification performance It starts to work as soon as it comes in to contact with water even if the unit is turned off The Hydro Stick should be change...

Страница 16: ...nk cap 44 Close tank cap well and place the tank on the main body 45 Replacement of the demineralization cartridge Always unplug the unit before removing the water tank Do not touch the water in the b...

Страница 17: ...17 en 44 34 35 36 37 38 39 41 43 40 42 45...

Страница 18: ...ption up to 40 W 125 W Humidity output up to 3 5 gallons 24 h Suitable for rooms up to 650 sq ft 60 m2 Dimensions LxWxH 9 5 x 10 3 x 12 2 in 24 x 26 x 31 cm Weight empty 6 6 lbs 3 kg Accessories AOS 7...

Страница 19: ...ge cap A Those directions are there in case you decide to use the refill option to replace the granules the purpose is for how to open and close the cap If you did open the cap before placing it in th...

Страница 20: ...as an influence on the humidity Reasons for low humidity level air circulation is very high air is fully exchanged se veral times per day the humidifier needs to starts its work from scratch insulatio...

Страница 21: ...heir highest level between recommended cleanings Good for one year the Hydro Stick ensures the humidifier s functionality while providing fresh humidification performance It needs to be replaced once...

Страница 22: ...22 en...

Страница 23: ...Please check our website www airoswiss net for further information AIR O SWISS is a registered trademark of PLASTON Group Switzerland 36484 01...

Отзывы: