14
English
NOTE:
All compressed air systems contain maintenance parts (e.g.,
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
NOTE:
Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE:
Any service operations not included in this section should be
performed by an authorized service center.
Maintenance Chart
Procedure
Daily
Weekly
Monthly
1 year or
200 Hours
Check safety valve
X
Inspect air
X
Drain air tank
X
Check pump oil level
X
Change pump oil**+
X
Oil leak inspection
X
Check for unusual noise/
vibration
X
Check for air leaks*
X
Clean compressor exterior
X
* To check for air leaks apply a solution of soapy water around joints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
** The pump oil must be changed after the first 20 hours of operation.
Thereafter, when using
ISO 100/SAE40, non-detergent, premium air
compressor oil
, change oil every 200 hours of operation or once a year,
whichever comes first.
+ Perform more frequent in dusty or humid conditions
Checking Safety Valve (Fig. 1)
WARNING
: Hot surfaces. Risk of burn. Aftercooler, pump head, and
surrounding parts are very hot, do not touch (see the Hot Surfaces
identified in Fig. 2). Allow compressor to cool prior to servicing.
WARNING:
Risk of bursting. If the safety valve does not work
properly, over-pressurization may occur, causing air tank rupture or
an explosion.
Before starting compressor, pull the ring on the safety valve to
make sure that the safety valve operates freely. If the valve is stuck
or does not operate smoothly, it must be replaced with the same
type of valve.
Checking Air Filter Element (Fig. 1)
WARNING
: Hot surfaces. Risk of burn. Aftercooler, pump head, and
surrounding parts are very hot, do not touch (see the Hot Surfaces
identified in Fig. 2). Allow compressor to cool prior to servicing.
1.
Ensure the On/Off switch (A) is in the OFF position.
2. Allow unit to cool.
3. Remove air filter (M) from unit.
4. Carefully pry filter top from base.
5. Remove element from filter base.
6. If element needs cleaning, blow out with air. Replace if needed.
Purchase replacement parts from your local dealer or authorized
service center. Always use identical replacement parts.
7. Place element back in filter base.
Содержание AM782HC4V