INSTALLATION INSTRUCTIONS

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT

SERVICE PANEL BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Exhaust Fan

1.

Unpack fan from the carton and confirm that all pieces are
present. In addition to the exhaust fan you should have:

1 - Grill
1 - Damper Assembly (attached)
1 - Instruction/Safety Sheet

2.

Remove the fan’s venturi assembly, which is secured in place
with one screw through the venturi 

(Figure 1)

. This is a captive

screw and will stay installed in the venturi. Keep the venturi
assembly and the grill in the carton until needed so they do
not get damaged or lost.

3.

Choose the location for your fan. To ensure the best air and
sound performance, it is recommended that the length of
ducting and the number of elbows
be kept to a minimum, and that
insulated hard ducting be used.
Larger duct sizes will reduce
noise and airflow restrictions.

4.

Select the most convenient electrical
knockout and remove using a
straight-blade screw driver 

(Figure

2)

.

SECTION 2

New Construction

1.

Using the gauge on the fan’s housing 

(Figure 3)

, line up

housing so that it will be flush with the finished ceiling or
wall. Position the fan so that the tabs rest flat against the
joist or stud and secure with four nails (not provided) to
ensure proper installation.

5

/

8

"

3

/

8

"

1

/

2

"

1

/

4

"

SECTION 3

Existing Construction

1.

Position housing against the joist or stud and trace an outline
of the housing onto the ceiling/wall material 

(Figure 4)

. Set

housing aside and cut opening, being careful not to cut or
damage any electrical or other hidden utilities. Place housing
next to the joist or stud and insure that it is flush with the
finished ceiling. Secure with four nails (not provided) to
ensure proper installation 

(Figure 3)

.

SECTION 4

Ducting

CAUTION:

 

ALL DUCTING MUST COMPLY WITH LOCAL

AND NATIONAL BUILDING CODES.

1.

Connect the ducting to the fan’s duct collar (

Figure 5)

. Secure

in place using tape or screw clamp. Always duct the fan to
the outside through a wall or roof cap.

NOTE:

 If damper detaches from unit, reattach by snapping the

collar back onto the unit. It is designed to only fit one way.

SECTION 5

Wiring

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT

SERVICE PANEL BEFORE STARTING INSTALLATION.

CAUTION:

 

ALL ELECTRICAL CONNECTIONS MUST BE

MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES,
OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE
THE SERVICES OF A QUALIFIED ELECTRICIAN.

1.

Run wiring from an approved wall switch carrying the
appropriate rating. One neutral (white), one ground (green or
bare copper), and one hot (black lead connected to the switch).
Secure the electrical wires to the housing with an approved
electrical connector. Make sure you leave enough wiring in
the box to make the connection to the fan’s receptacle.

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

www.airkinglimited.com

210572050 Rev. B 11-05

2 of 8

Содержание AS50

Страница 1: ...uding fire related construction 5 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating...

Страница 2: ...ng against the joist or stud and trace an outline of the housing onto the ceiling wall material Figure 4 Set housing aside and cut opening being careful not to cut or damage any electrical or other hi...

Страница 3: ...haust ducting 2 Check for any obstructions in the ducting The most common are bird nests in the roof cap or wall cap where the fan exhausts to the outside 3 Fan is operating louder than normal 3a Moto...

Страница 4: ...mitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts so these exclusions or limitations may not apply to you This warranty giv...

Страница 5: ...te est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de...

Страница 6: ...olive ou le montant et le fixer l aide de quatre clous non fournis pour assurer une installation ad quate 5 8 3 8 1 2 1 4 SECTION 3 Construction Existante 1 Positionner le cabinet contre la solive ou...

Страница 7: ...que tous les fils sont raccord s 2 Le ventilateur fonctionne mais l air circule plus 2 Obstruction dans les conduits d vacuation 2 V rifier pour toute obstruction dans les conduits Les plus courantes...

Страница 8: ...de la garantie implicite ou l exclusion ou la limitation de dommages indirects ou accessoires ainsi ces limitations et exclusions peuvent ne pas s appliquer vous Cette garantie vous donne des droits...

Отзывы: