background image

the wall switch to both the red wire from the fan’s light
receptacle and the black wire from the fan’s exhaust
receptacle. Connect the ground wire from the house to the
green wire from the fan’s grounding screw (

Figure 10)

. Use

approved methods for all connections.

4.

Carefully tuck wire back inside wire compartment and replace
wire compartment cover securing with the screw that was
removed earlier.

SECTION 6

Completing the Installation

1.

If the fan’s blower assembly was removed during the wiring
process, reinstall the blower by reversing the directions in

Step 1b

 in 

Section 5

 

Wiring

.

2.

Insert the fan’s plug into the receptacle (

Figure 7)

.

3.

Plug cord from lamp holder into the appropriate receptacle

(Figure 11)

.

4.

Line up slots in the grill with lances on inside of housing. Insert
included #8 screws through grill slots and into housing lances.
Tighten both screws until the grill fits snugly to the ceiling. DO
NOT OVER TIGHTEN (

Figure 12)

.

www.airkinglimited.com

210572216 New 7-06

4 of 12

CAUTION:

 

FAILURE TO SECURE THE GRILL MAY RESULT

IN A RATTLING OR HUMMING NOISE.

5.

Install 1 - 100 watt maximum, type A19 medium base
incandescent bulb (not included).

6.

The base installed in 

Step 4

 has a set of mounting hooks

for the glass light lens. One of the hooks is in a fixed position
while the other has a tension spring. The light lens has a
notch on either side of the lens. Slide one of the notches
into the fixed position hook. Then pull the other hook out
until the lens is able to fit into position and carefully release
the hook to slide the lens into the second notch. Make sure
the glass is held securely in place (

Figure 13)

.

7.

Restore power and test your installation.

SECTION 7

Use and Care

CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT

SERVICE PANEL BEFORE SERVICING THE UNIT.

1.

Cleaning the Grill:

 Refer to instructions in 

Section 6

Completing the Installation

, to remove grill and glass light

lens. Use a mild detergent, such as dishwashing liquid, and
dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR
SCOURING POWDERS. Completely dry all parts before
reinstalling. Refer to instructions in 

Section 6

 

Completing the

Installation

, to reinstall grill and glass light lens.

2.

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth

or gently vacuum the fan. NEVER IMMERSE ELECTRICAL
PARTS IN WATER.

CAUTION:

 

ALLOW BULB TO COOL BEFORE REPLACING.

3.

Changing the Light Bulb:

 Disconnect power to the unit.

Remove glass light lens from grill by pulling the tension
springed hook outward and sliding the glass out of the hooks

(Figure 13)

. Replace with a 100 watt maximum, type A19

medium base incandescent bulb. Refer to instructions in

Step 6

 of 

Section 6

 

Completing the Installation

, to reinstall

the light lens.

Figure 10

Ground

Hot (Red)

Supply

from

house

White

Figure 11

Cord

Lamp
Holder

Grill

Lances

#8 Screws

Figure 12

Lens

Figure 13

Lens

Hook

Tension

Spring

Notch

Содержание AKLC70DW

Страница 1: ...andards including fire related construction 5 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow...

Страница 2: ...bly attached 2 8 Screws 2 Lockwashers 4 Mounting Rails 1 Instruction Safety Sheet 2 Choose the location for your fan To ensure the best air and sound performance it is recommended that the length of d...

Страница 3: ...use to both the white wire from the fan s light receptacle and the white wire from the fan s exhaust receptacle Connect the black wire from SECTION 4 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL...

Страница 4: ...s has a notch on either side of the lens Slide one of the notches into the fixed position hook Then pull the other hook out until the lens is able to fit into position and carefully release the hook t...

Страница 5: ...anty gives you specific legal rights and you may have other rights which vary from state to state and province to province FOR PARTS OR TECHNICAL ASSISTANCE Please call 1 800 465 7300 MONDAY THROUGH F...

Страница 6: ...rew 5S1299007 8 2 6 B Screw 5S1999010 9 1 Polarized Connector 5S1299008 10 1 Receptacle 5S1999001 1 14 2 3 5 6 7 15 13 12 REPLACEMENT PARTS DIAGRAM Qty Description Replacement Part 11 1 Motor 5S223400...

Страница 7: ...n quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directive...

Страница 8: ...P E AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION SECTION 1 Pr paration du Ventilateur d vacuation 1 Sortir le ventilateur de sa boite et confirmer que toutes les pi ces sont pr sentes En pl...

Страница 9: ...un fil blanc provenant de la maison aux SECTION 4 Conduits AVERTISSEMENT TOUS LES CONDUITS DOIVENT TRE CONFORMESAUXCODESDUB TIMENTLOCAUXETNATIONAUX 1 Raccorder le conduit au collet de conduit du venti...

Страница 10: ...des crochets de montage est en une position fixe les autres crochets ont des ressorts de tension La vitre du luminaire a des encoches de chaque cot Glissez une des encoches de la vitre dans le croche...

Страница 11: ...rettes combin s ventilateur lumi re et ou les chaufferettes et les hottes de cuisine sont garantis pour cinq ann es partir de la date d achat contre les d fauts de main d uvre et ou de mat riel Cette...

Страница 12: ...S2234001 7 1 Vis 8 de B 5S1299007 8 1 Vis 6 de B 5S1999010 9 1 Polarized Connector 5S1299008 10 1 R ceptacle 5S1999001 de pi ce Qt Description de remplacement 11 1 Moteur 5S2234002 12 3 Vis de Montage...

Отзывы: