SECTION 3: COOLER ASSEMBLY
3.3
The Pneumatic Regulator (continued)
The pressure regulator has a locking handle. To adjust the regulator, lift the
setting knob and turn clockwise (to increase pressure-fan RPM) or anti-clock
wise (to decrease pressure-fan RPM) as required. Observe the adjusted
pressure on the gauge provided. When set, depress the adjustment knob to lock
the device.
Do not wash down the regulator with solvents as some of the composite
materials may be damaged.
3.4
Data Table For Cooler Assembly (for units with air motors only)
Dryer
Model
Regulator
Pressure
Oil Drip
Rate
Luber
Volume
Air Motor
Consumption
CATR
60 PSI
3 DPM
60 OZ
150 CFM
Note:
THE OIL DRIP RATE (DPM) FOR LUBRICATING THE PNEUMATIC AIR MOTOR
REFERS TO DRIPS PER MINUTE.
The dryer inlet temperature at all times should be maintained below 110ºF, in order
to maintain dew point without a required reduction in flow rate through the dryer.