background image

AD3000

AD3000

3

2

SAFETY INSTRUCTIONS

WARNING: RISK OF ELECTRIC SHOCK

Safety precautions should always be used when operating this or any electrical appliance.  

Decrease the risk of electrocution, electric shock, injury or fire by reading and following all the 

warnings below. 

Use this product only as described in this AirDoctor™ professional air purifier owner’s guide.  

To reduce the risk of electric shock, do not attempt to service the product in any way other than 

in the manner described in the “Maintenance” section of this guide. 

  Read all instructions before operating the AirDoctor™ professional air purifier.
  This product operates at 120V AC, 60Hz only. 
  Do not run the power cord under carpets, or cover with throw rugs.
  Do not operate the product in a greasy environment such as in the kitchen. This product is 

not intended to filter oil or grease from air.

  Do not use the AirDoctor™ professional air purifier in bathrooms, near sinks or other wet & 

humid environments, near fireplaces or in areas where flammable or combustible vapors or 

products may exist. 

  Always unplug the power cord from the electrical outlet when the purifier is not in use, 

before cleaning, inserting or removing parts or before moving to another location.

  Never run the air purifier unless it is fully assembled. 
  To reduce the risk of electric shock, this product has a polarized plug (one blade is wider 

than the other). This plug will fit into a polarized outlet only one way. If the plug does not fit 

into the outlet, contact qualified service personnel to install the proper outlet. Do not alter 

the plug in any way. 

  Always turn off all controls before unplugging the AirDoctor™ professional air purifier  

from outlet. 

  Attempting to service the AirDoctor™ professional air purifier in any way not described in 

this owner’s guide will void the warranty and could cause serious personal injury to the user 

and/or result in considerable damage to the unit. 

  Do not place the cord near a heated surface. 
  Never operate the AirDoctor™ professional air purifier if the plug or cord is damaged or 

appears damaged. Only qualified service personnel should replace a damaged power cord. 

  Never use the power cord to pick up, carry, drag, pull or lift the AirDoctor™ professional air 

purifier. Do not pull the cord against or around sharp corners and edges. This could result in 

injury to the user or damage to the cord. 

  Always remove the plug from its power outlet by holding onto the plug itself and pulling 

gently. Never pull on the cord itself to unplug it from its power outlet. 

  Use care when operating the AirDoctor™ professional air purifier by keeping all foreign 

objects, fingers and other body parts, hair, loose clothing and jewelry away from openings. 

  Never touch the AirDoctor™ professional air purifier or its plug when your hands are wet. 
  The AirDoctor™ professional air purifier is an electrical appliance. Adult supervision is 

required when operating around children.

PRODUCT BENEFITS

THE REVOLUTIONARY AIR DOCTOR™ PROFESSIONAL AIR PURIFIER 

CLEANS AIR WITH A ULTRA HEPA FILTER.  

 

The AirDoctor™ professional air purifier boasts many great features:

  Ultra HEPA filter removes particles from the air. Captures at least 99.97% of allergens  

 

and irritants that pass through the filter down to 0.3 microns.

  High quality carbon filter removes VOCs (Volatile Organic Compounds) and controls odors.

  Effectively removes smoke, pollen, dust, animal dander, dust mites from the air.

  Powerful and quiet fan has 4 speed settings to select desired cleaning level.

  Air Quality Monitor shows current air quality.

  Auto mode automatically adjusts fan speed depending on air quality.

  A 24 hour timer to set the time of operation, from 1 hour up to 24 hours. 

  Built-in ionizer revitalizes air.

  Night mode dims the control panel light when you sleep.

  Clean filter indicator light.

  Low power consumption-energy efficient, Energy Star approved.

Содержание AD3000

Страница 1: ...AD3000 MNL US 3 17 R1 USER MANUAL air purifier www airdoctorpro com ...

Страница 2: ...U Congratulations on purchasing the AirDoctor professional air purifier and your commitment to controlling the quality of your indoor air Welcome to an ideal world With the AirDoctor professional air purifier we provide Ultra HEPA filtration to purify the air and remove allergens In addition AirDoctor is equipped with and activated carbon filter to remove odor and VOCs Get ready to experience clea...

Страница 3: ... cause serious personal injury to the user and or result in considerable damage to the unit Do not place the cord near a heated surface Never operate the AirDoctor professional air purifier if the plug or cord is damaged or appears damaged Only qualified service personnel should replace a damaged power cord Never use the power cord to pick up carry drag pull or lift the AirDoctor professional air ...

Страница 4: ...ain 4 Placing the unit close to the source of air pollution can improve indoor air quality effectively KNOWING THE AIR DOCTOR AD3000 AIR PURIFIER MAIN PARTS 1 Front Cover 2 Pre Filter 3 Carbon Filter 4 Ultra HEPA Filter 5 Air Outlet 6 Touch Control Panel 7 Air Quality Sensor Cover 8 Air Quality Sensor 9 Air Quality Monitor The display will change color depending on air quality 1 3 2 4 6 Touch Cont...

Страница 5: ...ermines how rapidly you want to clean the air The LOW and MEDIUM settings are great for everyday use The HIGH setting is great for areas with more airborne contaminants such as excessive smoke pet dander etc or areas used frequently by allergy sufferers The BOOST setting is best used for shorter bursts of time when you want to rapidly purify the air 3 Auto Mode The Air Doctor is equipped with an a...

Страница 6: ...ew Ultra HEPA and carbon filters then insert the bottom of the inlet grill first and then snap the lupper part of the front cover back into position 4 To close the front cover first make sure the bottom hooks are properly in place before snapping it up to its upright and locked position CLEANING THE PRE FILTER 1 Make sure the unit is turned off and unplugged With the front of the unit facing forwa...

Страница 7: ...o you While this warranty gives you specific legal rights you may also have other rights which may vary from state to state CONTACT INFO FOR WARRANTY SERVICE AirDoctor P O Box 9159 Van Nuys CA 91409 8291 800 221 2515 www airdoctorpro com 2017 AirDoctor LLC All Rights Reserved TROUBLESHOOTING Before contacting our customer service department please try the following solutions PROBLEM REASON SOLUTIO...

Страница 8: ...ES a Before instituting an arbitration if you have any dispute we strongly encourage you to contact the Company to try to resolve the matter by calling 800 218 3560 although you are not required to do so b The arbitration of any claim or dispute under this Agreement shall be conducted in accordance with the expedited procedures set forth in the JAMS Comprehensive Arbitration Rules and Procedures a...