Air Conditioning Centre KYR-25CO/AG Скачать руководство пользователя страница 6

 

 

6.  Before cleaning the air-conditioner, always turn off or disconnect the power supply.   

7.  When moving the air-conditioner, always turn off and disconnect the power supply, and move it 

slowly.   

8.  To avoid the possibility of fire disaster, the air-conditioner shall not be covered.   

9.  All  the  air-conditioner  sockets  must  comply  with  the  local  electric  safety  requirements.  If 

necessary, please check it for the requirements. 

10. Children should be supervised to ensure that they do not play with the appliance. 

11. If  the  supply  cord  is  damaged,  it  must  be  replaced  by  the  manufacturer,  its  service  agent  or 

similarly qualified persons in order to avoid a hazard. 

12. This appliance can be used by children aged from 8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they  have been 

given supervision or instruction concerning use of the appliance in a safe way and understand the 

hazards  involved.  Children  shall  not  play  with  the  appliance.  Cleaning  and  user  maintenance 

shall not be made by children without supervision. 

13. The appliance shall be installed in accordance with national wiring regulations. 

14. Details of type and rating of fuses

T, 250V AC,3.15A or higher

.

 

15. Recycling 

 

 

 

 

 

This  marking  indicates  that  this  product  should  not  be  disposed  with  other  household  wastes 

throughout  the  EU.  To  prevent  possible  harm  to  the  environment  or  human  health  from 

uncontrolled  waste  disposal,  recycle  it  responsibly  to  promote  the  sustainable  reuse  of  material 

resources. To return your used device, please use the return and collection systems or contact the 

retailer  where  the  product  was  purchased.  They  can  take  this  product  for  environmentally  safe 

recycling. 

16. Contact authorized service technician for repair or maintenance of this unit. 

17. Do not pull, deform, or modify the power supply cord, or immerse it in water. Pulling or misuse of 

Содержание KYR-25CO/AG

Страница 1: ...1 Portable Air Conditioning User s Manual For Models KYR 25CO AG KYR 35GW AG KYR 45GW AG KYR 55GW AG Please read this user manual carefully to ensure proper use maintenance and installation...

Страница 2: ...2...

Страница 3: ...Name of Parts 5 3 Accessories 6 4 Appearance and Function of Control Panel 7 5 Appearance and Function of Remote Control 11 6 Operation Introduction 9 7 Installation Explanations 12 8 Maintenance Exp...

Страница 4: ...ously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware the refrigerants may not contain an odour Appliance s...

Страница 5: ...riate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry Repairs must be...

Страница 6: ...supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made...

Страница 7: ...Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants 22 Do not operate or...

Страница 8: ...off the power switch and disconnect the power supply It must be replaced by the dealer or a designated repair shop 2 Name of Parts Fig 1 1 Louver 6 Drainage outlet 2 Control panel 7 Air outlet 3 Front...

Страница 9: ...Window Connector 1 Housing adaptor 1 Remote Controller 1 Window Kit 1 Remote Controller 1 optional Window Connector 1 optional Window Kit 1 optional Air outlet 1 optional Dowel 2 optional Universal W...

Страница 10: ...s manual 4 Appearance and Function of Control Panel Cooling Heat pump model WIFI A Power on off 3 Dehumidifying B Fan speed 4 Fan C Temperature up 5 Heating D Temperature down 6 WIFI function E Operat...

Страница 11: ...remote controller in a location exposed to direct sunlight Do not submerge the remote control in any liquids 1 POWER Power on off 2 TIMER Timer on off 3 MODE Operation MODE 4 TEMP Temperature down 5 T...

Страница 12: ...earby 2 As shown in Fig 5 and Fig 5a install the exhaust hose and adjust the window position well Fig 5 Fig 5a 3 Connect drain hose well only for use during heating mode not KYR25CO 4 Insert the power...

Страница 13: ...ng keep an interval of at least 3 minutes between each ON OFF Power supply must meet the requirements The socket is for AC use Do not share one socket with other appliances Power supply is AC220V 240V...

Страница 14: ...ns on press this key the louver will swing continuously left and right by pressing this button again the movement will stop and the louver will remain in that position Some models 6 8 SLEEP mode While...

Страница 15: ...5s this enters the WIFI factory set up mode The unit is connected with WIFI if the WIFI indicator LED is on otherwise it is not connected When the WIFI indicator is flashing slowly the unit is in the...

Страница 16: ...the exhaust hose to the nearest window see Fig 9 Window Kit Installation The installation manner of window slider kit is mostly in horizontal or vertical As shown Fig 10 and Fig 10a check the min and...

Страница 17: ...17 Fig 10 Fig 10a Fig 11 Universal window kit accessory for mobile air conditioner Suitable for windows and doors Included in this kit 1 piece of zipped fabric 1 roll of hook and loop adhesive tape...

Страница 18: ...nner surface of the window flap on the handle side 3 Stick the widest side A of the large white fabric piece to the window frame and then stick the narrower side B to the window leaf handle side from...

Страница 19: ...d when the water is full please remove the rubber bung stopper at the bottom of unit and all water will be drained outside 5 Open the window gently and open the zipper of the fabric piece at level of...

Страница 20: ...ing be sure to disconnect the unit from any electric supply outlet 2 Do not use gasoline orother chemicals to clean the unit 3 Do not wash the unit directly 4 If the conditioner is damaged please cont...

Страница 21: ...ry it in the shade Mounting Put the air filter into the inlet grille replace the components as they were 8 2 Clean the Air conditioner Surface First clean the surface with a neutral detergent and wet...

Страница 22: ...lean the air inlet 3 Noisy The ground is not level or not flat enough Place the unit on a flat level surface if possible Sound comes from the flowing of the refrigerant inside the air conditioner It i...