motor. Make sure the drainage holes are sealed well.
-
If water splash motor is damaged, continuous drainage can be used. To connect the drain
hose to the bottom drainage outlet (
Fig.6
), the unit will also work well.
-
If splash motor is damaged, intermittent drainage can also be used. Under this condition, when
the water full indicator lights up, please connect a drain hose to the bottom drainage hole, then
all the water in the water tank will be drained outside. The unit can now work well again.
6.10 WIFI function (for some models)
- With the unit plugged in but power off using remote control, press and hold the SPEED button
for 5s, this enters the WIFI factory set up mode;
- The unit is connected with WIFI if the WIFI indicator LED is on, otherwise it is not connected.
When the WIFI indicator is flashing slowly, the unit is in the WIFI set up mode, if flashing quickly,
the unit is connected with WIFI;
- You can operate all the air conditioner functions by the mobile phone APP with the WIFI
connected.
7. Installation Explanations
7.1 Installation Explanations:
-
The portable air-conditioner shall be installed on a flat surface with empty space all around.
D
on’t block the air outlet, and the required distance around should be at least 30cm. (
See
Fig.8
)
-
Should not be installed in wet location, such as the laundry room, bathroom, shower, pool room etc.
-
Socket wiring should be in accordance with the local electric safety requirements.
7. Installation Explanations