18
Technical Information
Service Manual
and D. there are 7 states for the
e timer function is set in the last control before it is de-energized, the system
last control and the setting time is reached before the unit is de-energized, the unit will run according to the previous running mode after
it is energized again. But the timer function will terminate. The clock will not be memorized.
In cooling and heating mode (not available in auto, dehumidify, fan mode), press the Turbo button, the fan speed displayed super high
speed in the remote controller and the indoor fan rotates at super high speed.
L
A
B
C
D
Sleeping mode is available only in cooling and heating modes;
Cooling mode: at the base of initial set temperature by remote controller, the set temperature will increase automatically according to
people’s coziness within several hours after setting sleep function.
Heating mode: at the base of initial set temperature by remote controller, the set temperature will decrease automatically according to
people’s coziness within several hours after setting sleep function.
(5)Auto Changeover Mode
In this mode,the system selects the operation mode (cooling and fan) automatically according to the ambient temperature.The display
shows the actual operation mode and setting temperature.
There will be 30s delay for mode conversion.The protection function is the same as that of other modes.
1.When T
amb.
≥77°F,the cooling mode is selected.
2.For cooling only unit:when T
amb.
<71.6°F,the unit runs in fan mode.
3.When 71.6°F<T
indoor amb.
<77°F,upon initial startup,the unit will enter auto mode and run in automatic fan mode.if the other mode changes
to auto mode,the previous operation mode will remain.
(6)Auto fan speed Mode
In auto fan mode,the rotational speed of the fan for indoor unit is decided by the differential temperature between ambient temperature
and set temperature.In dry mode,the automatic fan speed is forced to be low.
(7)Lover Mode
After energization,the swing motor will open the horizontal louver to be open and then be close completely.And the air outlet is close.
In heating mode,if the swing function is not set,the horizontal louver will rotate to maximum in clockwise direction.Then it will
Models
Mode
Turbo
High fan
speed
Medium
fan speed
Low fan
speed
ACZEM4H4R09
Cooling
1260
1100
950
750
Heating
1320
1200
1100
950
ACZEM4C4R12
ACZEM4H4R12
Cooling
1330
1100
950
750
Heating
1350
1170
1050
950
setting time is reached.