52
8
★
★
★
Current
overload
protection
a.
the fan motor run abnormally;
b.
the condenser and
evaporator is dirty;
c.
the air inlet and outlet is
abnormally
9
Maximum
current
protection
a.
the outdoor control board is
short circuit;
b.
the drive board is short
circuit;
c.
the other components is short
circuit
10
★
Communication
trouble
between
outdoor unit
and driver
a.
the connection wires connect
loose
b.
the outdoor board or drive
board is failure;
11
★
Outdoor
EEPROM in
trouble
a.
the EEPROM chip is loose;
b.
the EEPROM chip inserted
with opposite direction;
c.
the EEPROM chip is failure
12
★
★
Outdoor
ambient
temperature
too low
protection
Outdoor ambient temperature
too low
13
★
Compressor
exhaust
temperature
too high
protection
a.
the compressor exhaust
temperature sensor is failure;
b.
the refrigerant of the unit is
not enough
14
★
★
Outdoor
ambient
temperature
sensor in
trouble
a.
the outdoor ambient
temperature sensor connect
loose;
b.
the outdoor ambient
temperature sensor is failure;
c.
the outdoor control board is
failure
15
★
★
Compressor
shell
temperature
too high
protection
a.
the compressor exhaust
temperature sensor connect
loose
b.
the refrigerant of the unit is
not enough
16
Anti-freeze
protection with
cooling or
overload
protection with
heating in
a.
the indoor coil temperature
sensor connect loose;
b.
the indoor coil temperature
sensor is failure;
c.
the indoor control board is
failure
Содержание ABXCI4H4S0
Страница 15: ...15 Outdoor 1854707...
Страница 20: ...20 L1 04...
Страница 21: ...21 Function Instruction 1 Major general technical parameters...
Страница 63: ...63 3 4...
Страница 64: ...64 5...
Страница 65: ...65...
Страница 66: ...66 DC fan motor test point...
Страница 68: ...68 6 test point Check the screw of IPM fastening...
Страница 70: ...70 test point The resistance of the compressor U W V W 7 SI and N test point...