Air Change WM-ERV Скачать руководство пользователя страница 3

 

WM-ERV Manual 2005.2.doc2 
 

 

AIR-CHANGE 100% OUTDOOR AIR WALL MOUNTED 

ENERGY RECOVERY VENTILATOR (WM-ERV) 

INTRODUCTION 

1.1 

Safety Considerations 

 
 

  IMPORTANT 

 

 

 

 

 

 

 

         

DO NOT LEAVE HEAT EXCHANGER EXPOSED TO DIRECT SUNLIGHT.

 Prolonged 

exposure to UV light can cause severe damage to the structure of the heat 
exchanger, and will void the warranty. 
 

WARNING  

Improper installation, service, maintenance or use can  cause fire, electrical shock or 
other conditions which may cause personal injury or property damage and will void the 
warranty.  Check with Air Change or nearest Air Change dealer for any information 
required on the ventilation unit equipment.   
 

  DANGER 

Electrical shock can cause personal injury or death.  Before performing any work 
on this equipment, the electrical supply must be turned off at the electrical 
service box to avoid the possibility of shock, injury or damage to equipment.   
 
Note: There may be more than one power supply circuit. 
 

 

1.2 

Note to Installer 

  Only trained and qualified personnel should install, repair or service air 

conditioning equipment.  Untrained supervised operatives can perform basic 
maintenance functions such as cleaning or replacing filters.  Service personnel 
must perform all other operations. 
 

  Installing and servicing air conditioning equipment can be hazardous due to 

electrical and mechanical components. 

 

  When working on electrical equipment, observe precautions in all literature, tags 

and labels attached to or shipped with unit. Follow all safety codes and 
guidelines. Wear safety goggles, work gloves and any protective clothing. 

 

  All work must comply with relevant SAA wiring rules and local authority codes.  

Installers must ensure that all statutory regulations and by laws have been 
addressed. 

 

Содержание WM-ERV

Страница 1: ...6 6563 Fax 08 8366 6501 Email sales sa air change com Queensland Unit 2 10 Central Court Hillcrest QLD 4118 PO Box 1175 Browns Plains QLD 4118 Phone 07 3809 3987 Fax 07 3809 3989 Email sales qld air c...

Страница 2: ...YSTEM COMPONENTS 7 3 1 General 7 3 2 System Components 7 3 2 1 Cabinet 7 3 2 2 Fans 7 3 2 3 Heat Exchanger 7 3 2 4 Filters 8 3 2 5 Electrical 8 3 3 Schematic Dimensional Data and Wiring Diagram Follow...

Страница 3: ...pply must be turned off at the electrical service box to avoid the possibility of shock injury or damage to equipment Note There may be more than one power supply circuit 1 2 Note to Installer Only tr...

Страница 4: ...or incomplete If major damage is apparent do not lift unit on to site without prior approval from Air change The unit was inspected prior to packing and was in perfect condition at that time Test loa...

Страница 5: ...eneration The introduced fresh air should also be above head height to avoid blowing directly on to occupants 2 1 3 External Inlet Outlet Considerations The exhaust discharge should be directed in a c...

Страница 6: ...m bottom 8 Timber or metal sealing batons for the rear of the unit will need to be supplied by the installer 9 Replace fan drawer heat exchanger and security screws filter and front grille 2 3 Electri...

Страница 7: ...fabricated wall and ceiling panels of are constructed of 1 2mm galvanised sheet metal bonded to 10mm aluminium polyethylene insulation 3 2 2 Fans Supply and exhaust fans are 80W centrifugal direct dri...

Страница 8: ...fitted to the return and fresh air intakes IMPORTANT If these units are being used during construction when adhesive sealers ducts new and used carpets are being installed make sure all equipment is f...

Страница 9: ...to NOTE Air Change can provide a heat exchanger replacement service on request WARNING Switch off unit before attempting to remove parts for cleaning 5 1 1 Enthalpy Heat exchanger Maintenance IMPORTAN...

Страница 10: ...ir change may request to see the maintenance schedule carried out 4 4 2 Monthly Maintenance Schedules Filters should be inspected frequently immediately after installation to confirm the frequency of...

Страница 11: ...WM ERV Manual 2005 2 doc2 11 Check cabinet for any paint chips or abrasions and treat accordingly Measure and record the amperage of each motor against nameplate details...

Страница 12: ...h will detail the service done to each unit This record is a summary of your service documentation for easy reference for management in case of a warranty claim Your equipment is a major investment an...

Отзывы: