-4- 

REPLACEMENT PROCEDURE 
 

WARNING: 

Unplug unit from wall outlet before starting replacement procedure. 

NOTE: 

Wear disposable, non-absorbent protective gloves prior to replacement procedure in case 

of accidental breakage of glass. 
 

1.  Loosen Screw on cover 
2.  Remove the unit and bulb from the duct. (See Figure 5) 
3.  Remove the bulb from the bulb socket. (See Figure 4) 
4.  Install  replacement  bulb  into  bulb  socket.  Do  not  handle  the  bulb  with  bare  hands.  Oils  on  the 

hands tend to reduce bulb life. 

5.  Wipe off the glass with isopropyl alcohol and a lint free wipe. 
6.  Screw Max-36 onto the duct with 4 mounting screws. 
7.  After  assembly  is  firmly  in  place,  plug  the  power  supply  cord  into  a  standard  electrical  wall  outlet. 

Check bulb operation by looking through the view porthole. A blue glow should be seen in the duct. 

 
WARNING: 

Never  expose  eyes  or  skin  to  UVC  light  from  any  source.  Looking  directly  at  the  UVC  light  may  cause 

permanent  eye  damage  or  blindness. 

Never  operate  the  Air-Care  UVC  Max-36  Air  Purifying  System  out  of  the 

plenum

. Avoid touching the glass portion of the bulb with your hands. 

 

8.  After replacing lamp, make sure a new 

Lamp Replacement Label 

(supplied with lamp replacement) 

is applied to the housing and dated with the date of installation.

 

 

NOTE: 

If  blue  light  leaks  through  any  portion  of  plenum  and/or  around  mounting  plate,  unplug  power 

supply cord immediately and seal affected areas and/or rotate ballast and repeat step #8 above. 
  

9.  UV bulbs contain a small amount of mercury, like a typical fluorescent bulb. Check with  your local 

waste management authority for local disposal or recycling requirements. 

 

 

 
WARNING: 

Never touch broken bulb or internal contents of bulb. The bulb contains mercury. 

 

NOTE: 

In  case  of  accidental  exposure  to  internal  contents  of  bulb,  wash  hands  and  any  other 

affected  skin  area  with  mild  detergent.  Remove  affected  clothing  immediately.  If  skin  surface  is 
pierced, seek medical attention immediately. 

 

TROUBLESHOOTING GUIDE 

1.  Make sure the unit has power 
2.  Make sure the switch is in the ON position 
3.  If unit still does not light up after replacing bulb, replace ballast. 

 
REPLACEMENT PARTS LIST 

For replacement parts, contact Air-Care at: 

Phone: 1-800-322-9919. 

Fax: 1-702-454-5225 

Email: [email protected] 

 
CLEAN-UP OF BROKEN BULBS 

(see warnings on page two of this manual) 

UVC  bulbs  contain  a  small  amount  of  mercury,  like  a  typical  fluorescent  bulb.  DO  NOT  touch  any  of  the 
mercury with your bare hands. 
1.  While wearing disposable, non-absorbent protective gloves, pick up the large pieces of glass with your 

hands. 

2.  Then,  vacuum  the  entire  area  with  a  standard  household  vacuum  cleaner  ensuring  the  removal  of  all 

bulb material. 

3.  Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed garbage 

bag. 

4.  Check with your local waste management authority for local disposal or recycling requirements.  
5.  Wash hands and remove and wash clothes for added safety measures. 

 
The health aspects associated with the use of these products and there ability to aid in disinfecting of environmental air have not been investigated by UL. 

 

WARNING: 

Never  expose  eyes  or  skin  to  UVC  light  from  any  source.  Looking  directly  at  the  UVC  light  may  cause 

permanent eye damage or blindness. 

Never operate the Air-Care UVC MAX 36 out of the plenum

. Avoid touching 

the glass portion of the bulb with your hands. 

 

 

Содержание MAX-36

Страница 1: ...of the home system and operates continuously to automatically purify the air in the home 24 hours a day This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation treatment or prevention of any disease or condition READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION ITEMS INCLUD...

Страница 2: ... noticeable If bulb is damaged cracked or broken do not touch bulb or other contents in carton Close carton and return to seller immediately In case of accidental exposure to internal contents of bulb wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If you touch the glass of the b...

Страница 3: ...ith bare hands Oils on the hands tend to shorten bulb life WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause permanent eye damage or blindness Never operate the Air Care UVC MAX 36 out of the plenum Avoid touching the glass portion of the bulb with your hands 6 Plug the power supply cord into a standard electric wall outlet Check bulb operat...

Страница 4: ...r local disposal or recycling requirements WARNING Never touch broken bulb or internal contents of bulb The bulb contains mercury NOTE In case of accidental exposure to internal contents of bulb wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately TROUBLESHOOTING GUIDE 1 Make sure the unit...

Страница 5: ... back to the purchaser s location Any additional expedited service charges for quicker shipping shall be born by the purchaser If the product or component is not found to be a warranty issue the purchaser will be responsible for return shipping charges Air Care is not responsible or liable for indirect special or consequential damages arising out of or in connection with the use of performance of ...

Страница 6: ... 6 Air Care is a Division of D P L Enterprises Inc 3868 E Post Road Las Vegas NV 89120 702 454 5515 Fax 702 454 5225 Website www air care com E mail Info Air Care com ...

Отзывы: