10.4 Internal electrical failures
In the case of an internal failure caused by a defect
component or short-circuit, the drive will stop running
and display the occurred failure.
Error number
Description
1
undervoltage on DC link
2
overvoltage on DC link
10
current measurement fails
permanently
20
overload during start up process
64
short-circuit failure
97
multiple errors at the same time,
i.e. undervoltage and overload error
98
communication failure from
controller
11. Technical Information
Power: 20-750 Watt
Voltage: 100-240 VAC
Max. current: 4.4 A
Frequency: 50-60 Hz
Isolation class: F
Protection class: IP55
Max. rpm: 2550
Motor torque: 2.4 Nm (from 800 rpm)
0RWRUHI¿FLHQF\,(USP
Capacity: 5-70 m3/hr
Pump head: 0-7.2 m
+\GUDXOLFHI¿FLHQF\
&HUWL¿FDWHV &(9'(
IE4 A++
Mechanical Seal: Eagle Burgmann MG1Q1Q1VGG
Connection Suction: G 3“ x 20 mm - Outer thread
Connection Pressure: G 3“ x 20 mm - Outer thread
Tel: +31 (0)522-468 963 | Fax: +31 (0)522-468 944 | [email protected]
Subject to typesetting and printing errors