background image

7

IX Series:

 Input Programming

The IS-IPRY adaptor has 4 inputs that can be programmed to trigger a call-in from a specific door station or master station to a 

specific master station or group of master stations. 

The IS-IPRY inputs can have different calling rules than the default calling rule set during the IX Series programming.

Select the call-in priority level for each input using the 

Priority

 drop down menu. 

Enter the target IP address of the station for remote call-in.

Click 

Apply Settings

 to save the changes. Do not reboot the adaptor at this time.  

Click 

APPLICATION SETUP

 to return to the Application Configuration Screen. 

Click on 

Destinations

 next to the input being configured. Another window will open. Enter the station number of the 

master stations to be called when the input is triggered. 

When the target IP address is a door station, a maximum of 20 master stations can be entered.

When the target IP address is a master station, a maximum of 20 master stations or 1 group can be entered. A group can 

consist of up to 50 master stations and must be created using the IX Support Tool.

Check the 

Enable

 box beside each station entered. 

Click on 

Apply Settings

 then click 

Reboot

 to restart the adaptor with the changes.

The IS-IPRY has 4 relays that can be programmed to trigger when a specific door station is calling, while in 

communication, or while calling and communicating. The relays can also be programmed for door release from one or 

multiple IP master station(s).

Set the IS-IPRY for use with the IS-IP Series (refer to page 5).

From the 

Device Configuration

 screen, click 

APPLICATION SETUP

.

Application Setup button

IS-IP Series:

 Relay Output Programming

Содержание IS-IPRY

Страница 1: ...IS IPRY Programming Manual For use with IX Series IS IP Series 1016 Input Output Network Adaptor...

Страница 2: ...he IX Support Tool and for setting up the mobile device SIF ini File IX Series and IS IP Series Stations Only Create a SIF ini file in order for the IX Series and IS IP Series door stations and master...

Страница 3: ...pdate to save the changes for the station then repeat the process for each station that will be associated with the IS IPRY F After completing steps C D and E for each station upload the changes Click...

Страница 4: ...message will appear Continue to the website C Enter the administrator ID and password Default ID aiphone Default Password aiphone D Select Transmission setting under Uploading SIF setting data from th...

Страница 5: ...d for access to the web browser interface AIPHONE Select the Aiphone system type the relay is to be used with The Aiphone system type that the relay is being integrated with will need to be selected C...

Страница 6: ...y Closed Active while Calling from Source Active while Communicating Active during Calling and Communicating The IX Series allows for door release partitioning When the IS IPRY relay action is set for...

Страница 7: ...number of the master stations to be called when the input is triggered When the target IP address is a door station a maximum of 20 master stations can be entered When the target IP address is a mast...

Страница 8: ...a door station TermID will be xx 101 xx represents the line in which the station resides under IP Unit Registration in the IS Host programming Example 01 101 Door station in address location 1 03 001...

Страница 9: ...ons Table see page 8 Check the Flag box beside each master station that will be allowed to trigger this relay for door release Once all master stations have been checked click Apply Settings at the bo...

Страница 10: ...IX Mobile Server Functionality table Click on Apply Settings then click Reboot to restart the adaptor with the changes Refer to pages 12 15 for steps on adding a mobile device to the IX system using t...

Страница 11: ...the other devices in the system 1 2 3 4 5 6 Click the button to save changes Click the button to save changes Note Station Information here to refer to later Number Name IP Address For Programmers In...

Страница 12: ...e to C Program Files Support Tool System Data name of system Setting The IX Support Tool creates a configuration file for each device in the system and saves it to a folder within the Support Tool pro...

Страница 13: ...e device Tap the Menu icon 6 6 7 Tap Setup Enter the Admin ID and Password and tap OK Default ID admin Default Password admin 7 8 8 A pop up will appear stating New configuration applied 9 To unlock t...

Страница 14: ...iguration file saved from the IX Support Tool to this folder 1 2 3 4 5 1 2 3 4 5 Launch the application on the mobile device Tap the Menu icon then tap Settings 6 6 7 Tap Setup Enter the Admin ID and...

Страница 15: ...PS 2420D R1 NO R3 NO Door Strike Bell Power Transformer use proper power for the strike mag lock or external signaling device being used PS 1215DIN PS 2420D R2 NO R4 NO R1 NO R3 NO R2 NO R4 NO I1 I2...