25
Option 1
Option 2
Option 3
PICOGLF4012120240VS ONLY!
Option 1
Input: Hot line + Neutral for
120V AC
Output: Hot line + Neutral - 120V AC
Option 2
Input: Hot line + N Ground
120V AC
Output: Hot line + Neutral - 120V AC
Warning:
If only using a 120V load, use Hot line 1
+ Neutral, when the load power is more than 50% of
the inverter's rated power then use Hot line 2 +
Neutral.
Option 3
Input: Hot line +
Neutral - 120V AC
Output: Hot line + N Hot line - 240/120V
AC
Caution
:
Wiring Option 2 and Wiring Option 3 are designed for split phase models 120/240V. 240 Volt
input and 120/240 Volt output.
Wiring Option 1 for single phase models only.
Model# PICOGLF4012120240VS ONLY. This inverter is 120 AC input to 120/240 AC output.
WARNING
For split phase models, AC input neutral is not required in wiring. Never connect input neutral to
output neutral. Damage will occur and is not covered under warranty.
Always switch on the inverter before plugging in any appliance.
WARNING
The output voltage of this unit must never be connected in its input AC terminal, overload or
damage may occur.
*We do NOT recommend connecting AC input to a GFCI circuit as it will cause the supplied GCFI
to pop intermittently and fail to supply power to the charger and bypass power through inverter.
Always switch on the inverter before plugging in any device.
Содержание Global LF Series
Страница 1: ...Global LF Series Pure Sine Wave Inverter Charger User s Manual Version 9 0 PICOGLF10W PICOGLF60W ...
Страница 2: ......
Страница 17: ...15 2 5 8 LED Indicator Lights Status ...
Страница 29: ...27 3 6 Install Flange 1000W 1500W Models 2000W 3000W Models 4000W 6000W Models ...
Страница 30: ...28 DC Side View ...
Страница 36: ...34 ...
Страница 38: ...36 Appendix 2 Installation Diagram DC shunt is not required ...
Страница 39: ......
Страница 40: ...614 01206 09 ...